BODIPY-phosphane as a versatile tool for easy access to new metal-based theranostics

2012

A new BODIPY-phosphane was synthesized and proved to be a versatile tool for imaging organometallic complexes. It also led to easy access to a new family of theranostics, featuring gold, ruthenium and osmium complexes. The compounds' cytotoxicity was tested on cancer cells, and their cell uptake was followed by fluorescence microscopy in vitro.

Boron Compoundsinorganic chemicalsCell SurvivalPhosphinesINHIBITIONchemistry.chemical_elementGOLD COMPOUNDSRutheniumInorganic ChemistryMetalchemistry.chemical_compoundGold CompoundsPOLYPYRIDINE COMPLEXESCoordination ComplexesCHEMISTRYCell Line TumorFluorescence microscopeHumansOrganic chemistryOsmiumCytotoxicityAGENTSMicroscopy ConfocalChemistryOsmiumCombinatorial chemistryRutheniumMetalsvisual_artPHOTOPHYSICAL PROPERTIESCancer cellvisual_art.visual_art_mediumMODESGoldBODIPYDYESBEHAVIOR
researchProduct

Determination of particle number and brightness using a laser scanning confocal microscope operating in the analog mode

2008

We describe a method to obtain the brightness and number of molecules at each pixel of an image stack obtained with a laser scanning microscope. The method is based on intensity fluctuations due to the diffusion of molecules in a pixel. For a detector operating in the analog mode, the variance must be proportional to the intensity. Once this constant has been calibrated, we use the ratio between the variance and the intensity to derive the particle brightness. Then, from the ratio of the intensity to the brightness we obtain the average number of particles in the pixel. We show that the method works with molecules in solution and that the results are comparable to those obtained with fluctu…

BrightnessHistologyMicroscopeLaser scanningGreen Fluorescent ProteinsCHO CellsTransfectionFluorescencelaw.inventionCricetulusOpticslawCricetinaeMicroscopyAnimalsParticle SizeInstrumentationMicroscopy ConfocalN&B confocal microscopyPixelbusiness.industryDynamic rangeChemistryDetectorPhoton countingMedical Laboratory TechnologyAnatomybusinessAlgorithms
researchProduct

Giant Dzyaloshinskii-Moriya Interaction and Room-Temperature Nanoscale Skyrmions in CoFeB/MgO Heterostructures

2021

Magnetic skyrmions in heavy metal (HM)/CoFeB/MgO structures are of particular interest for skyrmion-based magnetic tunnel junction (MTJ) devices because of their reliable generation, stability and read-out through purely electrical methods. To optimize the properties, such as stability, a strong Dzyaloshinskii-Moriya interaction (DMI) is required at room temperature. Here, using first-principles calculations, we demonstrate that giant DMI can be obtained in Ir/CoFe structures with an Fe-terminated configuration. Moreover, Brillouin light scattering measurements show that indeed Ta/Ir/Co20Fe60B20/MgO thin films with perpendicular magnetic anisotropy exhibit a large DMI value (1.13 mJ/m2), wh…

Brillouin zoneTunnel magnetoresistanceMaterials scienceCondensed matter physicsSkyrmionHeterojunctionThin filmMagnetic force microscopeNanoscopic scaleLight scatteringSSRN Electronic Journal
researchProduct

Scanning electron microscopy characterization of ZnSe single crystals grown by solid-phase recrystallization

2000

ZnSe single crystals were grown from n-type microcrystalline boules by a Solid Phase Recrystallization (SPR) method. The recrystallizations were performed under different atmospheres, Ar or Se, and pressures to investigate the influence of growth conditions on the structural features of the resulting crystals. The samples were mechanically and mechano-chemically polished in a bromine methanol solution and, then, etched in HCl for a short time, before characterization. The homogeneity and the nature of defects in the crystals were studied by Cathodoluminescence (CL) in the scanning electron microscope (SEM). CL measurements show the existence of slip bands in the recrystallized samples, like…

BromineMaterials scienceScanning electron microscopeMechanical EngineeringLüders bandchemistry.chemical_elementCrystal growthCathodoluminescenceCondensed Matter PhysicsCrystallographic defectSpectral lineCrystallographyMicrocrystallinechemistryMechanics of MaterialsGeneral Materials ScienceMaterials Science and Engineering: B
researchProduct

Immunogold Labeling to Detect Streptococcus pyogenes Cas9 in Cell Culture and Tissues by Electron Microscopy

2019

Final publication is available from Mary Ann Liebert, Inc., publishers https://doi.org/10.1089/crispr.2019.0032. The CRISPR-Cas9 system is a powerful and yet precise DNA-editing tool in rapid development. By combining immunogold labeling and electron microscopy with the novel CRISPR-Cas9 system, we propose a new method to gain insight into the biology of this tool. In this study, we analyzed different Cas9-induced systems such as HEK293T cell line, murine oligodendrocyte progenitor cells, brain and liver to detect Cas9 expression by immunoelectron microscopy. Our results show that while Cas9 expression could be found in the nuclei and nucleopores of transfected HEK293T cells, in transfected…

CRISPR-Cas9 systemelectron microscopyChemistryCas9immunogold labelingImmunogold labellingmedicine.disease_causeMolecular biologylaw.inventionlawStreptococcus pyogenesGeneticsmedicineElectron microscopeBiotechnology
researchProduct

Cadmium clusters in CdI2layered crystals: the influence on the optical properties

2007

The influence of overstoichiometric Cd i atoms on the optical properties of cadmium iodide layered crystals has been investigated. The results of optical absorption, luminescence, and luminescence excitation studies of CdI 2 crystals with controlled deviation from stoichiometric composition allow observing correlations between the Cd i concentration and features in absorption and emission spectra up to concentrations of 10 18 cm -3 . At higher concentrations the overstoichiometric cadmium atoms form clusters, which were observed using scanning electron microscopy. The extinction spectra of (CdI i ) n clusters are calculated in the frame of Mie theory and are found to correlate with the opti…

CadmiumScanning electron microscopeMie scatteringAnalytical chemistrychemistry.chemical_elementCondensed Matter Physicschemistry.chemical_compoundCadmium iodidechemistryGeneral Materials ScienceEmission spectrumAbsorption (chemistry)LuminescenceExcitationJournal of Physics: Condensed Matter
researchProduct

Multianalytical Approach to explain the darkening process of hematite pigment in paintings from ancient Pompeii after accelerated weathering experime…

2013

[EN] In this paper, recently excavated fresco painting fragments from the House of Marcus Lucretius (Pompeii) and not exposed to the atmosphere since the eruption of the Mount Vesuvius were subjected to a controlled SO2 atmosphere and high relative humidity. These experiments were conducted in order to simulate under accelerated conditions the possible deterioration of the hematite pigment and plaster. The mineralogical transformation of the polychromy and plaster was monitored using mainly Raman spectroscopy, a non-destructive technique, but also infrared spectroscopy (FT-IR) and scanning electron microscopy energy-dispersive X-ray spectroscopy (SEM-EDS). After different exposure cycles to…

CalciteGypsumScanning electron microscopeGeneral Chemical EngineeringGeneral EngineeringMineralogyInfrared spectroscopyta6132Weatheringengineering.materialHematiteAnalytical Chemistrychemistry.chemical_compoundPigmentchemistryvisual_artengineeringvisual_art.visual_art_mediumNuclear chemistryMagnetite
researchProduct

Crystallized nano-sized alpha-tricalcium phosphate from amorphous calcium phosphate: microstructure, cementation and cell response

2015

New insight on the conversion of amorphous calcium phosphate (ACP) to nano-sized alpha tricalcium phosphate (α-TCP) provides a faster pathway to calcium phosphate bone cements. In this work, synthesized ACP powders were treated with either water or ethanol, dried, crystallized between 700 and 800 °C, and then cooled at different cooling rates. Particle size was measured in a scanning electron microscope, but crystallite size calculated by Rietveld analysis. Phase composition and bonding in the crystallized powder was assessed by x-ray diffraction and Fourier-transform infrared spectroscopy. Results showed that 50 nm sized α-TCP formed after crystallization of lyophilized powders. Water trea…

Calcium PhosphatesHot TemperatureMaterials scienceScanning electron microscopeBiomedical EngineeringMineralogyBioengineeringApatitelaw.inventionBiomaterialslawApatitesMaterials TestingSpectroscopy Fourier Transform InfraredHumansAmorphous calcium phosphateParticle SizeCrystallizationCells CulturedRietveld refinementBone CementsMesenchymal Stem CellsMicrostructureChemical engineeringvisual_artMicroscopy Electron Scanningvisual_art.visual_art_mediumNanoparticlesParticle sizeCrystallitePowdersCrystallizationPowder DiffractionBiomedical Materials
researchProduct

Histomorphological study of the bone regeneration capacity of platelet-rich plasma, bone marrow and tricalcium phosphate Experimental study on pigs

2009

Introduction: Bone defects are rather common after oral surgery and may prove difficult to repair. Objective: We provide a histomorphological analysis of the bone regenerative capacity of platelet-rich plasma at different concentrations and the extraction of platelet-rich bone marrow, compared with -tricalcium phosphate. Methodology: We performed an experimental study on 8 pigs, in which we performed trepanations of the mandible in order to place the materials to be studied. Using an electron microscope, we observed the samples obtained and took a series of photographs in order to analyze the samples through a gray-scale histogram system. Results: Ossification phenomena were present in 96% …

Calcium PhosphatesMalemedicine.medical_specialtyBone RegenerationBones growthSwineCreixement dels ossosDentistrychemistry.chemical_elementBiocompatible MaterialsMandibleCalciumlaw.inventionchemistry.chemical_compoundBone MarrowlawInternal medicinemedicineAnimalsBone marrowBone regenerationGeneral DentistryPorcPlatelet-Rich Plasmabusiness.industryOssificationMandiblePhosphate:CIENCIAS MÉDICAS [UNESCO]medicine.anatomical_structureEndocrinologyOtorhinolaryngologychemistryPlatelet-rich plasmaMedul·la òssiaUNESCO::CIENCIAS MÉDICASSurgeryBone marrowmedicine.symptomElectron microscopebusiness
researchProduct

Galvanic deposition and characterization of brushite/hydroxyapatite coatings on 316L stainless steel

2016

In this work, brushite and brushite/hydroxyapatite (BS, CaHPO4·H2O; HA, Ca10(PO4)6(OH)2) coatings were deposited on 316L stainless steel (316LSS) from a solution containing Ca(NO3)2·4H2O and NH4H2PO4 by a displacement reaction based on a galvanic contact, where zinc acts as sacrificial anode. Driving force for the cementation reaction arises from the difference in the electrochemical standard potentials of two different metallic materials (316LSS and Zn) immersed in an electrolyte, so forming a galvanic contact leading to the deposition of BS/HA on nobler metal. We found that temperature and deposition time affect coating features (morphology, structure, and composition). Deposits were char…

Calcium PhosphatesMaterials scienceGalvanic anodeScanning electron microscopeMaterials ScienceEnergy-dispersive X-ray spectroscopyBioengineering02 engineering and technologyCondensed Matter Physicengineering.material010402 general chemistry01 natural sciencesCorrosionHydroxyapatiteBiomaterialssymbols.namesakeCoatingGalvanic cellBrushiteMechanical EngineeringMetallurgyBiomedical applicationElectrochemical Techniques021001 nanoscience & nanotechnologyStainless Steel0104 chemical sciencesGalvanic depositionDurapatiteSettore ING-IND/23 - Chimica Fisica ApplicataChemical engineeringMechanics of Materialsengineeringsymbols316LSSBrushite0210 nano-technologyRaman spectroscopy
researchProduct