Search results for "Microscopy"
showing 10 items of 3390 documents
Micro-Raman characterization of graphene grown on SiC(000-1)
2014
Graphene (Gr) was grown on the C face of 4H-SiC under optimized conditions (high annealing temperatures ranging from 1850 to 1950°C in Ar ambient at 900 mbar) in order to achieve few layers of Gr coverage. Several microscopy techniques, including optical microscopy (OM), ?Raman spectroscopy, atomic force microscopy (AFM) and atomic resolution scanning transmission electron microscopy (STEM) have been used to extensively characterize the lateral uniformity of the as-grown layers at different temperatures. ?Raman analysis provided information on the variation of the number of layers, of the stacking-type, doping and strain.
Unraveling the LiNbO3 X-cut surface by atomic force microscopy and density functional theory
2014
The ${\text{LiNbO}}_{3}$(2$\overline{1}\overline{1}0$) surface, commonly referred to as X-cut, is investigated by means of atomic force microscopy and first-principles calculations. Atomically resolved atomic force microscopy images show geometrical patterns not compatible with truncated bulk terminations. Fast Fourier transformation of the real-space images shows an oblique surface unit cell with lattice parameters of $a=0.75\ifmmode\pm\else\textpm\fi{}0.02$ nm, $b=0.54\ifmmode\pm\else\textpm\fi{}0.02$ nm, and $\ensuremath{\alpha}=94.{8}^{\ensuremath{\circ}}$. Comparing these experimental results with the theoretical models of stable surface terminations provides clear evidence for the for…
Local Time-Dependent Charging in a Perovskite Solar Cell
2016
Efficient charge extraction within solar cells explicitly depends on the optimization of the internal interfaces. Potential barriers, unbalanced charge extraction, and interfacial trap states can prevent cells from reaching high power conversion efficiencies. In the case of perovskite solar cells, slow processes happening on time scales of seconds cause hysteresis in the current-voltage characteristics. In this work, we localized and investigated these slow processes using frequency-modulation Kelvin probe force microscopy (FM-KPFM) on cross sections of planar methylammonium lead iodide (MAPI) perovskite solar cells. FM-KPFM can map the charge density distribution and its dynamics at intern…
Single-molecule switching with non-contact atomic force microscopy
2011
We report upon controlled switching of a single 3,4,9,10-perylene tetracarboxylic diimide derivative molecule on a rutile TiO(2)(110) surface using a non-contact atomic force microscope at room temperature. After submonolayer deposition, the molecules adsorb tilted on the bridging oxygen row. Individual molecules can be manipulated by the atomic force microscope tip in a well-controlled manner. The molecules are switched from one side of the row to the other using a simple approach, taking benefit of the sample tilt and the topography of the titania substrate. From density functional theory investigations we obtain the adsorption energies of different positions of the molecule. These adsorp…
Correlating Cathodoluminescence and Kelvin Probe Force Microscopy Measurements of Methylammonium-Free 2D Ruddlesden Popper Passivated Perovskite Abso…
2021
Three-dimensional atomic force microscopy mapping at the solid-liquid interface with fast and flexible data acquisition
2016
We present the implementation of a three-dimensional mapping routine for probing solid-liquid interfaces using frequency modulation atomic force microscopy. Our implementation enables fast and flexible data acquisition of up to 20 channels simultaneously. The acquired data can be directly synchronized with commercial atomic force microscope controllers, making our routine easily extendable for related techniques that require additional data channels, e.g., Kelvin probe force microscopy. Moreover, the closest approach of the tip to the sample is limited by a user-defined threshold, providing the possibility to prevent potential damage to the tip. The performance of our setup is demonstrated …
Structural characterization of selective area growth GaN nanowires by non-destructive optical and electrical techniques
2015
The growth selectivity and structural quality of GaN nanowires obtained by plasma-assisted molecular beam epitaxy on pre-patterned GaN(0001) templates are investigated by means of non-destructive techniques. Optimum control over the nanowire arrangement and size requires a pitch between the mask apertures below twice the diffusion length of Ga atoms. Lower pitches, however, seem to slightly diminish the structural quality of the material, as revealed by the increase of the Raman peak linewidths. The photoluminescence spectra of the nanowires show a considerable presence of basal plane stacking faults, whose density increases for decreasing nanowire diameter. The capabilities of Kelvin probe…
Insights into Kelvin probe force microscopy data of insulator-supported molecules
2015
We present a detailed analysis and understanding of Kelvin probe force microscopy (KPFM) data for a system of point charges in a vacuum-dielectric tip-sample system. Explicit formulae describing the KPFM signal $\ensuremath{\Delta}V$ are derived for the two KPFM operation modes, namely amplitude modulation and frequency modulation (FM). The formulae allow for a physical interpretation of the resulting KPFM signal, reveal contributing parameters, and especially disclose an additive behavior. We numerically evaluate these equations and show exemplary KPFM slice data for a single point charge. The theoretical analysis is complemented by two-dimensional FM-KPFM maps obtained experimentally on 2…
Assessment of Polarity in GaN Self-Assembled Nanowires by Electrical Force Microscopy
2015
In this work, we demonstrate the capabilities of atomic force microscopies (AFMs) for the nondestructive determination of the polarity of GaN nanowires (NWs). Three complementary AFMs are analyzed here: Kelvin probe force microscopy (KPFM), light-assisted KPFM, and piezo-force microscopy (PFM). These techniques allow us to assess the polarity of individual NWs over an area of tens of μm(2) and provide statistics on the polarity of the ensemble with an accuracy hardly reachable by other methods. The precise quantitative analysis of the tip-sample interaction by multidimensional spectroscopic measurements, combined with advanced data analysis, has allowed the separate characterization of elec…
Use of a collagen/elastin-membrane for the tissue engineering of dermis.
1999
In an experimental model in rats, xenogeneic membranes consisting of processed native collagen and elastin were grafted to serve as a template for the formation of a neo-dermis, while in vitro-cultured autogeneic keratinocytes were applied on top of this to restore an epidermis. The process of tissue reconstruction and the digestion of the grafted membrane components were analysed by histological and immunohistochemical methods as well as electron microscopy. Approximately 3 weeks post grafting the membranes were completely vascularised and colonized by different types of cells. After 6 weeks, the collagenous fibres of the graft were mostly replaced by newly formed collagenous texture, wher…