Search results for "Microscopy"
showing 10 items of 3390 documents
Direct measurement of forces between particles and bubbles
1999
One of the elementary stages of the flotation process is the formation of an aggregate between the particle and a bubble. This aggregate formation is governed by hydrodynamic, capillary and interparticle forces. During the last four years, techniques have been developed to measure directly the force between a colloidal particle and a bubble. These techniques are closely related to the development of atomic force microscopy. Advantages and possibilities, as well as limits and drawbacks are described.
Textures in hexatic films of nonchiral liquid crystals: Symmetry breaking and modulated phases
1994
Novel modulated textures, such as stripes and multiarmed star defects, have been observed in freely suspended films of nonchiral liquid crystals just below the smectic-$C$ to hexatic phase transition. Detailed studies using depolarized reflection microscopy suggest that the stripes are locally chiral surface splay domains of the smectic-$L$ phase, a tilted hexatic not previously identified in thermotropic liquid crystals. Line defects which form additional domain walls in the hexatic lattice lead to characteristic modulations of the basic one-dimensional stripe pattern. Inside thick circular islands, for example, stripes form circumferentially and the lines form centered 12-armed stars, res…
The effect of magnetic anisotropy on the spin configurations of patterned La(0.7)Sr(0.3)MnO3 elements.
2013
We study the effect of magnetocrystalline anisotropy on the magnetic configurations of La0.7Sr0.3MnO3 bar and triangle elements using photoemission electron microscopy imaging. The dominant remanent state is a low energy flux-closure state for both thin (15 nm) and thick (50 nm) elements. The magnetocrystalline anisotropy, which competes with the dipolar energy, causes a strong modification of the spin configuration in the thin elements, depending on the shape, size and orientation of the structures. We investigate the magnetic switching processes and observe in triangular shaped elements a displacement of the vortex core along the easy axis for an external magnetic field applied close to t…
Investigation of a novel material for magnetoelectronics: Co2Cr0.6Fe0.4Al
2003
Heusler compounds are promising candidates for future spintronics device applications. The electronic and magnetic properties of Co2Cr0.6Fe0.4Al, an electron-doped derivative of Co2CrAl, are investigated using circularly polarized synchrotron radiation and photoemission electron microscopy (PEEM). Element specific imaging reveals needle shaped Cr rich phases in a homogeneous bulk of the Heusler compound. The ferromagnetic domain structure is investigated on an element-resolved basis using x-ray magnetic circular dichroism (XMCD) contrast in PEEM. The structure is characterized by micrometre-size domains with a superimposed fine ripple structure; the lateral resolution in these images is abo…
Towards the origin of the shear force in near-field microscopy
2001
The shear force from a gold or a graphite sample acting on an approaching near-field optical probe is studied in detail. The adiabatic and dissipative contributions to the force are clearly distinguished by monitoring the amplitude as well as the phase of the tip vibration when the tip approaches the surfaces. We also take into account that not only the damping and the resonance frequency but also the mass of the system changes when the tip approaches the surface. The relative strength of the contributions to the force varies differently but characteristically with the distance of the two samples, starting at a much larger distance in the case of graphite. The adiabatic contribution is lar…
Optical properties of biocompatible polyaniline nano-composites
2006
Abstract Polyaniline (PANI) is an electro-active polymer of great interest thanks to its outstanding physical and chemical properties which make it suitable for various applications in optics, bioelectronics, biosensors, diagnostics and therapeutic devices. Unfortunately, PANI is infusible and insoluble in most common solvents and, thus, very difficult to process. In the attempt of improving processability, yet preserving its interesting properties, PANI has been synthesized in the form of particles and dispersed into a hydrogel matrix. The synthesis of PANI–hydrogel composites proceeds via γ-irradiation of PANI dispersions as obtained by ‘in situ’ polymerization of aniline in the presence …
Motion Artifact Detection in Confocal Laser Endomicroscopy Images
2018
Confocal Laser Endomicroscopy (CLE), an optical imaging technique allowing non-invasive examination of the mucosa on a (sub)- cellular level, has proven to be a valuable diagnostic tool in gastroenterology and shows promising results in various anatomical regions including the oral cavity. Recently, the feasibility of automatic carcinoma detection for CLE images of sufficient quality was shown. However, in real world data sets a high amount of CLE images is corrupted by artifacts. Amongst the most prevalent artifact types are motion-induced image deteriorations. In the scope of this work, algorithmic approaches for the automatic detection of motion artifact-tainted image regions were develo…
Transferability of Deep Learning Algorithms for Malignancy Detection in Confocal Laser Endomicroscopy Images from Different Anatomical Locations of t…
2019
Squamous Cell Carcinoma (SCC) is the most common cancer type of the epithelium and is often detected at a late stage. Besides invasive diagnosis of SCC by means of biopsy and histo-pathologic assessment, Confocal Laser Endomicroscopy (CLE) has emerged as noninvasive method that was successfully used to diagnose SCC in vivo. For interpretation of CLE images, however, extensive training is required, which limits its applicability and use in clinical practice of the method. To aid diagnosis of SCC in a broader scope, automatic detection methods have been proposed. This work compares two methods with regard to their applicability in a transfer learning sense, i.e. training on one tissue type (f…
Examination Technique of Confocal Laser Endomicroscopy
2007
The first publication about a confocal fluorescence microscope integrated into the distal tip of a conventional colonoscope (Pentax EC 3830FK, Tokyo, Japan) appeared in 2004 [1], showing that in vivo microscopy at subcellular resolution (0.7 µm) simultaneously displayed with white-light endoscopy had become possible. Today, endomicroscopy can be performed in the upper and lower GI tract [2]–[10]. This chapter deals with the examination technique of confocal laser endomicroscopy.