Search results for "Miniaturization"
showing 10 items of 44 documents
Nanosensors for intelligent packaging
2021
Abstract Intelligent packaging is an emerging area with a high potentials. Sensors and indicators are key elements, together with enabling technologies, for the development of a new generation of packaging able to interact with the sample and the user. Nanotechnology offers interesting opportunities for the development of active components, integration with the packaging, miniaturization, communication, and batteries. However, its use in intelligent packaging is still limited. We report herein a revision of recent examples of sensors including nanomaterials or nanostructures with potential application in packaging. The references include time temperature indicators, pH, moisture and pressur…
Focus on atom optics and its applications
2010
Atom optics employs the modern techniques of quantum optics and laser cooling to enable applications which often outperform current standard technologies. Atomic matter wave interferometers allow for ultra-precise sensors; metrology and clocks are pushed to an extraordinary accuracy of 17 digits using single atoms. Miniaturization and integration are driven forward for both atomic clocks and atom optical circuits. With the miniaturization of information-storage and -processing devices, the scale of single atoms is approached in solid state devices, where the laws of quantum physics lead to novel, advantageous features and functionalities. An upcoming branch of atom optics is the control of …
Compact, cost-effective and field-portable microscope prototype based on MISHELF microscopy
2016
AbstractWe report on a reduced cost, portable and compact prototype design of lensless holographic microscope with an illumination/detection scheme based on wavelength multiplexing, working with single hologram acquisition and using a fast convergence algorithm for image processing. All together, MISHELF (initials coming from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel) microscopy allows the recording of three Fresnel domain diffraction patterns in a single camera snap-shot incoming from illuminating the sample with three coherent lights at once. Previous implementations have proposed an illumination/detection procedure based on a tuned (illumination wavelengths centered…
Portable microwave assisted extraction: An original concept for green analytical chemistry.
2013
International audience; This paper describes a portable microwave assisted extraction apparatus (PMAE) for extraction of bioac-tive compounds especially essential oils and aromas directly in a crop or in a forest. The developed procedure, based on the concept of green analytical chemistry, is appropriate to obtain direct in-field information about the level of essential oils in natural samples and to illustrate green chemical lesson and research. The efficiency of this experiment was validated for the extraction of essential oil of rosemary directly in a crop and allows obtaining a quantitative information on the content of essential oil, which was similar to that obtained by conventional m…
Osseointegration of miniscrews: a histomorphometric evaluation.
2007
SUMMARY Mini-implants and miniscrews are commonly used in orthodontics to provide additional temporary intraoral anchorage. Partial osseointegration represents a distinct advantage in orthodontic applications, allowing effective anchorage to be combined with easy insertion and removal. This article reports the histomorphometric fi ndings of the osseointegration of bracket screw bone anchors (BSBAs). In an experimental animal study, four BSBAs were inserted in the alveolar process of the lower jaw in each of fi ve male beagle dogs, aged 6.5 months from the same mother. Eleven screws were lost during the study, nine of them due to lack of primary stability. One screw was removed at the end of…
Extraction of Entrapped Capsules from the Small Bowel by Means of Push-and-Pull Enteroscopy with the Double-Balloon Technique
2005
The new technique of push-and-pull enteroscopy using the double-balloon technique (double-balloon enteroscopy) makes it possible to remove swallowed foreign bodies causing intestinal obstruction deep in the small bowel without the need for surgical laparotomy. This report describes two cases of enteroscopic removal of entrapped capsules. In one patient with acute recurrent intestinal bleeding and recurrent abdominal pain, Crohn's disease had been suspected on capsule endoscopy. The second patient, with known Crohn's disease, was suffering from abdominal pain and underwent capsule endoscopy for investigation of the small bowel. Prior enteroclysis had not revealed stenoses in either patient. …
Dynamic in vivo Imaging of Microvasculature and Perfusion by Miniaturized Confocal Laser Microscopy
2008
<i>Introduction:</i> Microvasculature and associated pathologies mandate dynamic imaging. We evaluated a novel miniaturized confocal laser scanning probe for in vivo visualization of blood vessels, blood flow, cell tracking and perfusion in both healthy rodents and disease models.<i> Methods:</i> The hand-held confocal microscopy system allowed a 500- to 2,400-fold magnification at a dynamically variable imaging depth. Different intravital stains were used alone or in combination for tissue, nuclear, plasma and vascular endothelial cell staining and for blood flow visualization, and targeted staining for individual cell populations. <i>Results:</i> Precis…
In-vivo confocal real-time mini-microscopy in animal models of human inflammatory and neoplastic diseases
2007
Background and study aims Although various improvements in tissue imaging modalities have recently been achieved, in-vivo molecular and subsurface imaging in the field of gastroenterology remains a technical challenge. In this study we evaluated a newly developed, handheld, miniaturized confocal laser microscopy probe for real-time in-vivo molecular and subsurface imaging in rodent models of human disease. Materials and methods The minimicroscope uses a 488-nm, single line laser for fluorophore excitation. The optical slice thickness is 7 microm, the lateral resolution 0.7 microm. The range of the z-axis is 0-250 microm below the tissue surface. Imaging was performed using different fluores…
High frequency modeling technique for three phase power electronics module
2015
Nowadays, the high integrated power electronics modules (PMs), characterized by high speed, low loss and hard ware miniaturization, represent a new technology that meets the emerging demands of many applications, such us vehicle and home appliance, renewable energy sources in smart grid. The integration process and the high switching speeds increase the PM electromagnetic emissions that can create electromagnetic interference (EMI) with electric/electronic devices near the PMs. For this reason, electromagnetic compatibility (EMC) have to be carefully considered, yet in the design phase, to guarantee the reliability of PM systems. In this paper a method to develop a high frequency (HF) model…
On the Possibility of Miniature Diamond-Based Magnetometers Using Waveguide Geometries
2018
Micromachines 9(6), 276 (2018). doi:10.3390/mi9060276