Search results for "Multislice"

showing 10 items of 69 documents

Standardized T2* map of normal human heart in vivo to correct T2* segmental artefacts.

2007

A segmental, multislice, multi-echo T2* MRI approach could be useful in heart iron-overloaded patients to account for heterogeneous iron distribution, demonstrated by histological studies. However, segmental T2* assessment in heart can be affected by the presence of geometrical and susceptibility artefacts, which can act on different segments in different ways. The aim of this study was to assess T2* value distribution in the left ventricle and to develop a correction procedure to compensate for artefactual variations in segmental analysis. MRI was performed in four groups of 22 subjects each: healthy subjects (I), controls (II) (thalassemia intermedia patients without iron overload), thala…

AdultMalemedicine.medical_specialtyheart; thalassemia; MRI; heart iron overload; multislice multi-echo T2*Segmental analysisT2 mappingGroup iiheartSensitivity and SpecificityT2* mapVentricular Dysfunction LeftReference ValuesIn vivoImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingMultisliceSpectroscopyheart iron overloadbusiness.industryMyocardiumHealthy subjectsReproducibility of ResultsHuman heartImage Enhancementmultislice multi-echo T2*Magnetic Resonance ImagingSurgerymedicine.anatomical_structuresegmental artefactVentricleThalassemiaMolecular MedicineFemaleArtifactsNuclear medicinebusinessMRI
researchProduct

T2-mapping of the sacroiliac joints at 1.5 Tesla: a feasibility and reproducibility study

2018

Objective: To evaluate the reproducibility of T2 relaxation time measurements of the sacroiliac joints at 1.5 T. Materials and methods: Healthy volunteers underwent an oblique axial multislice multiecho spin-echo sequence of the sacroiliac joints at 1.5 T. Regions of interest were manually drawn using a dedicated software by two musculoskeletal radiologists to include the cartilaginous part of the sacroiliac joints. A senior radiologist performed the measurement twice, while a resident measured once. Intra- and inter-observer reproducibility was tested using the Bland-Altman method. Association between sex and T2 relaxation times was tested using the Mann-Whitney U test. Correlation between…

AdultMalemusculoskeletal diseasesmedicine.medical_specialtyT2 mappingReproducibility of Result030218 nuclear medicine & medical imagingT2 mapping03 medical and health sciences0302 clinical medicineHealthy volunteersmedicineHumansRadiology Nuclear Medicine and imagingMultislice030203 arthritis & rheumatologySacroiliac jointReproducibilitymedicine.diagnostic_testbusiness.industryReproducibility of ResultsSacroiliac JointMagnetic resonance imagingImage EnhancementHealthy VolunteerMagnetic Resonance ImagingHealthy VolunteersFeasibility StudieCartilagemedicine.anatomical_structureOrthopedic surgeryMann–Whitney U testFeasibility StudiesFemaleNuclear medicinebusinessHumanSkeletal Radiology
researchProduct

Preferential patterns of myocardial iron overload by multislice multiecho T2* CMR in thalassemia major patients.

2010

T*(2) multislice multiecho cardiac MR allows quantification of the segmental distribution of myocardial iron overload. This study aimed to determine if there were preferential patterns of myocardial iron overload in thalassemia major. Five hundred twenty-three thalassemia major patients underwent cardiac MR. Three short-axis views of the left ventricle were acquired and analyzed using a 16-segment standardized model. The T*(2) value on each segment was calculated, as well as the global value. Four main circumferential regions (anterior, septal, inferior, and lateral) were defined. Significant segmental variability was found in the 229 patients with significant myocardial iron overload (glob…

AdultMalepreferential patternIron OverloadAdolescentmyocardial iron overloadThalassemiamultislice multiecho T*2Myocardial ironcardiovascular magnetic resonanceBasal (phylogenetics)HumansMedicineRadiology Nuclear Medicine and imagingMultisliceChelation therapyChildHemochromatosisRetrospective Studiesmedicine.diagnostic_testbusiness.industryMyocardiumbeta-ThalassemiaHeartMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance ImagingRadiographymedicine.anatomical_structureVentriclethalassemia majorFemalebusinessNuclear medicine
researchProduct

Influence of myocardial fibrosis and blood oxygenation on heart T2* values in thalassemia patients

2009

Purpose To determine whether T2* measurements quantifying myocardial iron overload in thalassemia patients are influenced by myocardial fibrosis and blood oxygenation. Materials and Methods Multislice multiecho T2* was performed in 94 thalassemia patients in order to quantify myocardial iron overload. The left ventricle was automatically segmented into a 16-segment standardized heart model, and the T2* value on each segment as well as the global T2* were calculated. Delayed enhanced cardiovascular magnetic resonance (DE-CMR) images were obtained to detect myocardial fibrosis. The blood oxygenation was assessed by the noninvasive measurement of partial pressure of oxygen (pO2). Results Myoca…

AdultMalethalassemiamedicine.medical_specialtyIron OverloadAdolescentT2* valueThalassemiaContrast MediaStatistics NonparametricFibrosisInternal medicineblood oxygenationmedicineHumansRadiology Nuclear Medicine and imagingMultisliceChildAgedRetrospective Studiesmedicine.diagnostic_testbusiness.industryMagnetic resonance imagingRetrospective cohort studyMiddle Agedmedicine.diseaseFibrosisOxygenmedicine.anatomical_structureVentriclemyocardial fibrosiCardiologyBlood oxygenationFemaleMyocardial fibrosisbusinessJournal of Magnetic Resonance Imaging
researchProduct

Multicenter validation of the magnetic resonance t2* technique for segmental and global quantification of myocardial iron

2009

Purpose To assess the transferability of the magnetic resonance imaging (MRI) multislice multiecho T2* technique for global and segmental measurement of iron overload in thalassemia patients. Materials and Methods Multiecho T2* sequences were installed on six MRI scanners. Five healthy subjects (n = 30) were scanned at each site; five thalassemia major (TM) patients were scanned at the reference site and were rescanned locally (n = 25) within 1 month. T2* images were analyzed using previously validated software. Results T2* values of healthy subjects showed intersite homogeneity. On TM patients, for global heart T2* values the correlation coefficient was 0.97, coefficients of variation (CoV…

Adultmyocardial iron; T2* techniqueCorrelation coefficientHeart VentriclesIronReference siteTransferabilityMyocardial ironReference ValuesImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingMultislicemyocardial ironAnalysis of VarianceReproducibilitymedicine.diagnostic_testbusiness.industryMyocardiumHealthy subjectsT2* techniqueReproducibility of ResultsMagnetic resonance imagingMagnetic Resonance ImagingItalyLiverThalassemiabusinessNuclear medicineJournal of Magnetic Resonance Imaging
researchProduct

State-of-the-art imaging in palaeopathology: the value of multislice computed tomography in visualizing doubtful cranial lesions

2002

Non-invasive imaging techniques are of great value in palaeopathology. Computed tomography (CT) is widely established to visualize changes in human remains that occurred both pre and post mortem. Since 1999 an advanced form of helical CT—so called Multislice-CT (MSCT)—has become available for clinical purposes. We now present for the first time three historic cranial lesions of doubtful aetiology visualized by MSCT. Both original images and virtual reconstructions of the specimens are of high quality. In combination with peri-lesional bone density measurements these images allow an improved assessment of aetiology. The cases presented are diagnosed by MSCT as being of intra vitam nature in …

Archeologymedicine.medical_specialtymedicine.diagnostic_testbusiness.industryAnthropologymedicineComputed tomographyRadiologyMultislice computed tomographybusinessPre and postPaleopathologyInternational Journal of Osteoarchaeology
researchProduct

Long-term prognosis of patients with a zero calcium score assessed by Multislice Computed Tomography Coronary Angiography.

2011

Purpose Methods and Materials Results Conclusion References Personal Information

ArteriosclerosisPrognosicalcium scoreSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCardiacCT-AngiographyOutcomes analysisMultislice Computed Tomography Coronary Angiography.
researchProduct

Prevalence of anatomical variants and coronary anomalies in 543 consecutive patients studied with 64-slice CT coronary angiography

2008

The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 +/- 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 +/- 55 mm. The intermediate branch was present in the 21.9%. A variable number …

Coronary angiographyAdultMalemedicine.medical_specialty64 slice ctCoronary Vessel AnomaliesContrast MediaCoronary Angiographymultislice computed tomographyIopamidolCoronary circulationInternal medicineCoronary CirculationCoronary artery circulation Multislice computed tomography Anatomical variants AnomaliesmedicinePrevalenceHumansRadiology Nuclear Medicine and imagingNeuroradiologyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryInterventional radiologyGeneral MedicineMiddle Agedanatomical variantsIopamidolCoronary arteriesmedicine.anatomical_structurecoronary artery circulation; multislice computed tomography; anatomical variants; anomaliesRadiology Nuclear Medicine and imagingCardiologycoronary artery circulationRadiographic Image Interpretation Computer-AssistedanomaliesFemaleRadiologybusinessTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCardiacmedicine.drugArteryEuropean Radiology
researchProduct

Right coronary artery arising from pulmonary trunk: assessment with conventional coronary angiography and multislice computed tomography coronary ang…

2009

We present a case of a 59-year-old man who was admitted to the hospital because of atypical chest pain and dyspnea. Conventional coronary angiography showed an anomalous origin of the right coronary artery from the pulmonary trunk. The patient underwent multislice computed tomography in order to clarify the origin and course of the anomalous vessel. The aim of this report is to emphasize the role of multislice computed tomography as an accurate noninvasive imaging tool in the evaluation of coronary artery anomalies.

Coronary angiographyRight coronary arteryMalemedicine.medical_specialtyCoronary Vessel AnomaliesContrast MediaPulmonary ArteryCoronary AngiographyIopamidolAngina PectorisPredictive Value of Testsmedicine.arterymedicineHumansPulmonary Trunkbusiness.industryGeneral MedicineMultislice computed tomographyMiddle AgedIopamidolmedicine.anatomical_structureDyspneaRight coronary arteryPredictive value of testsPulmonary arteryRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedArterymedicine.drugJournal of cardiovascular medicine (Hagerstown, Md.)
researchProduct

INFLUENCE OF INTRA-CORONARY ENHANCEMENT ON DIAGNOSTIC ACCURACY WITH 64-SLICE CT CORONARY ANGIOGRAPHY

2008

We assessed the effect of intra-coronary attenuation on diagnostic accuracy using 64-slice computed tomography coronary angiography (CT-CA). We enrolled 170 patients with suspected coronary artery disease who underwent conventional coronary angiography (CA) and 64-slice CT-CA (100 ml of Iomeprol 400 mg I/ml at 4 ml/s). The study population was divided into two groups (85 patients each based on median attenuation of 326 HU) based on mean arterial attenuation; group 1 with low attenuation and group 2 with high attenuation. Diagnostic accuracy for the detection of significant coronary artery stenosis was determined for both groups using CA as reference standard. Overall, 163 significant stenos…

Coronary artery disease . Coronary angiography . Multislice computed tomography . Iodine concentration . Diagnostic accuracySettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct