Search results for "Multislice"

showing 10 items of 69 documents

MR-tomographische Messung der diastolischen Relaxation hypertrophierter linker Ventrikel mit Single-slice-multi-phase-Technik

1993

In order to assess diastolic ventricular function in hypertensive patients, a single-slice multiphase sequence was used in order to measure contraction and early diastolic relaxation. There was no difference in the contraction velocity between hypertensives and normals (Vsys. n.r. = 56.1 +/- 13.8% LVDV/s vs. 51.7 +/- 8.6% LVEDV/s, stat, n. sign.). Early diastolic relaxation velocity in hypertensives was reduced as compared with the control group (Vdiast. 1n.r. = 37.9 +/- 13.1% LVEDV/s vs. 47.1 +/- 9.6% LVEDV/s, p < 0.05). There was no linear relation between abnormal relaxation and the extent of myocardial hypertrophy. Hypertensives with myocardial hypertrophy frequently had reduced early d…

PhysicsNuclear magnetic resonanceVentricular functionDiastoleRelaxation velocityEarly diastolicRadiology Nuclear Medicine and imagingMultisliceContraction velocitySystoleMuscle hypertrophyRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Meßfehlerschätzung bei der MR-tomographischen Volumetrie des linken Ventrikels mit Mehrschicht-Technik

1992

A multi-slice technique for MRT measurements of the left ventricular volume is much faster than the use of single-slice methods and is therefore better tolerated, leaving time for additional measurements. The end-diastolic left ventricular volume can be reliably measured by this method (123.3 +/- 13.5 ml vs. 124.1 +/- ml). The end-systolic volume is consistently overestimated by 23.7 +/- 18.3% compared with the reference value obtained by single slice measurements (47.9 +/- 8.9 ml vs 39.1 +/- 7.9 ml). Correspondingly, stroke volume and ejection fraction is underestimated on average by 10.6 +/- 9.7% and 10.6 +/- 7.6% respectively).

PhysicsObservational errorEjection fractionbusiness.industryStroke volumemedicine.anatomical_structureNuclear magnetic resonanceVolume (thermodynamics)VentriclemedicineEnd-diastolic volumeRadiology Nuclear Medicine and imagingMultisliceNuclear medicinebusinessEnd-systolic volumeRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

RUOLO DELLA TOMOGRAFIA COMPUTERIZZATA MULTISLICE NELLA DIAGNOSTICA NON INVASIVA DELLA MALATTIA ATEROSCLEROTICA CORONARICA

2005

RUOLO DELLA TOMOGRAFIA COMPUTERIZZATA MULTISLICE NELLA DIAGNOSTICA NON INVASIVA DELLA MALATTIA ATEROSCLEROTICA CORONARICA
researchProduct

64-MDCT ECG gating in the evaluation of pre and post-operative ascending aorta: what is essential to know and necessary to report?

2007

Settore MED/36 - Diagnostica Per Immagini E RadioterapiaMultislice CT ascending aorta
researchProduct

MultiSlice human organ extraction based on GVF

2008

Segmentation techniques based on active contours algorithm are widely used in medical imaging. Unfortunately, they require a lot of parameters to be used and this can rep- resent an issue for those physicians with not much informatics skills. This paper proposes a software tool which allows to segment multiple slice can differ organ extraction setting a small number of parameters. Moreover, the tool offers the functionality to perform a multiple segmentation the same time, so that an entire volume composed by hundreds slices can be segmented.

Software toolComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONContrast MediaUser-Computer InterfaceImaging Three-DimensionalSoftware DesignMedical imaging Segmentation GVFComputer GraphicsImage Processing Computer-AssistedMedical imagingHumansMedicineSegmentationMultisliceComputer visionDiagnosis Computer-AssistedSettore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionibusiness.industryReproducibility of ResultsModels TheoreticalInformaticsArtificial intelligenceTomography X-Ray ComputedbusinessAlgorithmsSoftwareVolume (compression)
researchProduct

About Objective 3-D Analysis of Airway Geometry in Computerized Tomography

2008

The technology of multislice X-ray computed tomography (MSCT) provides volume data sets with approximately isotropic resolution, which permits a noninvasive 3-D measurement and quantification of airway geometry. In different diseases, like emphysema, chronic obstructive pulmonary disease (COPD), or cystic fribrosis, changes in lung parenchyma are associated with an increase in airway wall thickness. In this paper, we describe an objective measuring method of the airway geometry in the 3-D space. The limited spatial resolution of clinical CT scanners in comparison to thin structures like airway walls causes difficulties in the measurement of the density and the thickness of these structures.…

SwineComputer sciencePulmonary diseaseComputed tomographyGeometrySensitivity and SpecificityCystic fibrosisImaging phantomImaging Three-DimensionalParenchymamedicineAnimalsMultisliceElectrical and Electronic EngineeringQuantitative computed tomographyLungImage resolutionCOPDLungRadiological and Ultrasound Technologymedicine.diagnostic_testPhantoms ImagingReproducibility of ResultsBronchographyComputational geometrymedicine.diseaserespiratory tract diseasesComputer Science ApplicationsRadiographic Image Enhancementmedicine.anatomical_structureAirway wallRadiographic Image Interpretation Computer-AssistedTomographyTomography X-Ray ComputedAirwayAlgorithmsSoftwareIEEE Transactions on Medical Imaging
researchProduct

Three-year follow-up of patients at intermediate probability of coronary artery disease assessed with Multislice Computed Tomography Coronary Angiogr…

2011

Purpose Methods and Materials Results Conclusion References Personal Information

assessed with Multislice Computed Tomography Coronary Angiography.ArteriosclerosisFollow-upSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCardiacCT-AngiographyOutcomes analysiscoronary artery disease
researchProduct

Preoperative assessment of GI stromal tumors with 40-row multislice CT

2006

gastrointestinal stromal tumorsmultislice computed tomography
researchProduct

Non-invasive visualisation of coronary atherosclerosis: state-of-art.

2007

Coronary artery disease remains the leading cause of death in the Western world. Non-invasive coronary artery imaging challenges any diagnostic modality because the coronary arteries are small and tortuous, whereas cardiac contraction and respiration cause motion artifacts. Therefore, non-invasive coronary imaging requires high spatial and temporal resolution. This review discusses the feasible applications in coronary imaging of magnetic resonance imaging and multi-slice computed tomography (MSCT), which are currently the only non-invasive diagnostic modalities for direct coronary atherosclerosis imaging. Particular attention and focus is devoted to the potential indications and clinical i…

medicine.medical_specialtyAcute coronary syndromeLumen (anatomy)Coronary Artery DiseaseCoronary AngiographyCoronary artery diseaseImage Processing Computer-AssistedMedicineHumansCoronary atherosclerosismedicine.diagnostic_testCardiac cyclebusiness.industryMagnetic resonance imagingGeneral Medicinemedicine.diseaseMagnetic Resonance ImagingCoronary arteriesmedicine.anatomical_structureacute coronary syndrome coronary atherosclerosis coronary imaging multislice CT plaqueRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E RadioterapiaArtery
researchProduct

Quantification and Characterization of Pulmonary Emphysema in Multislice-CT

2003

The new technology of the Multislice-CT provides volume data sets with approximately isotropic resolution, which permits a non invasive measurement of diffuse lung diseases like emphysema in the 3D space. The aim of our project is the development of a full automatic 3D CAD (Computer Aided Diagnosis) software tool for detection, quantification and characterization of emphysema in a thoracic CT data set. It should supply independently an analysis of an image data set to support the physician in clinical daily routine. In this paper we describe the developed 3D algorithms for the segmentation of the tracheo-bronchial tree, the lungs and the emphysema regions. We present different emphysema des…

medicine.medical_specialtyLungComputer scienceSoftware toolPulmonary emphysemaCADrespiratory systemrespiratory tract diseasesData setmedicine.anatomical_structureComputer-aided diagnosismedicineMultislice ctSegmentationRadiology
researchProduct