Search results for "Node"
showing 10 items of 1701 documents
Technology Impact on Neutron-Induced Effects in SDRAMs : A Comparative Study
2021
International audience; This study analyses the response of synchronous dynamic random access memories to neutron irradiation. Three different generations of the same device with different node sizes (63, 72, and 110 nm) were characterized under an atmospheric-like neutron spectrum at the ChipIr beamline in the Rutherford Appleton Laboratories, UK. The memories were tested with a reduced refresh rate to expose more single-event upsets and under similar conditions provided by a board specifically developed for this type of study in test facilities. The board has also been designed to be used as a nanosatellite payload in order to perform similar tests. The neutron-induced failures were studi…
Quartz Crystal Microbalance And Electrical Impedance Characterization Of Nickel Dissolution Process.
2005
Abstract. The anodic nickel dissolution in acid media is analysed by means of EQCM and EIS techniques. The experimental impedance spectra have been fitted to the equivalent circuit which corresponds to two consecutive electron transfers followed by a Ni(II) desorption. That way rate constants and surface concentrations of the Ni(0) and Ni(I) species are obtained. EQCM also provides information about the mechanism of deposition and passivation of nickel as well as the hydrogen evolution.
Electric field manipulation in Al/CdTe/Pt detectors under optical perturbations
2017
Abstract Al/CdTe/Pt detectors are very attractive devices for high-resolution X-ray spectroscopy, even though they suffer from polarization phenomena, which cause a progressive time degradation of the spectroscopic performance. In this work we investigated on the time dependence of the electric field of an Al/CdTe/Pt detector under optical perturbation by means of Pockels effect measurements. A tunable laser with wavelengths ranging within 700−1000 nm and a 940 nm light emitting diode (LED) were used. The measurements of both the electric field profile and the total current were used to better understand the effects of the optical perturbation on polarization phenomena. The results point ou…
Multi-technique characterization of gold electroplating on silver substrates for cultural heritage applications
2017
Proceedings of the 12th European Conference on Accelerators in Applied Research and Technology (ECAART12).-- et al.
Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors.
2020
In the last two decades, great efforts have been made in the development of 3D cadmium–zinc–telluride (CZT) detectors operating at room temperature for gamma-ray spectroscopic imaging. This work presents the spectroscopic performance of new high-resolution CZT drift strip detectors, recently developed at IMEM-CNR of Parma (Italy) in collaboration with due2lab (Italy). The detectors (19.4 mm × 19.4 mm × 6 mm) are organized into collecting anode strips (pitch of 1.6 mm) and drift strips (pitch of 0.4 mm) which are negatively biased to optimize electron charge collection. The cathode is divided into strips orthogonal to the anode strips with a pitch of 2 mm. Dedicated pulse processing analysis…
CEMS of insulators by use of gas-flow counters
1994
Gas-flow CEMS counters are usually designed in such a manner that the sample to be investigated is inserted into the counter and serves as the backing cathode. If the sample consists of an insulating material, serious problems are expected by charging-up effects similar to those appearing in Maze counters. These problems are discussed in detail. It could be shown by experiments with glass samples that their very low surface conductivity is sufficient to allow a defined operation of such gas-flow CEMS detectors. The electric field strength between the surface of the sample and the anode has to be equal or higher than that between the entrance window and the anode. This can be ensured by an a…
Design and construction of the fast photon detection system for COMPASS RICH-1
2010
International audience; New photon detectors, based on the use of multi-anode photo-multiplier tubes coupled to individual lens telescopes and read out with a dedicated read-out electronics system, equip the central region of the Cherenkov imaging counter RICH-1 of the COMPASS experiment at CERN SPS. They are characterised by high photon yield, fast response and high rate capability and are successfully in operation since the 2006 COMPASS data taking. The photon detection system fully matches the expected performance. The design and construction of the photon detectors are described in detail.
Particle identification with the fast COMPASS RICH-1 detector
2009
International audience; A new photon detection system for the COMPASS RICH-1 detector has been designed and installed. In the central region, the project is based on multi-anode photo-multiplier technology accompanied by charge sensitive, high resolution and dead-time free time digitization. In the outer area, only the readout electronics for the existing photon detectors has been replaced. Details on the detector upgrade and its performance are presented.
Development of new CdZnTe detectors for room-temperature high-flux radiation measurements
2017
Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room-temperature X-ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling-heater-method (THM)-grown CZT detectors, recently developed at IMEM-CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm−2 at 1000 V cm−1), a…
Electrical properties of Au/CdZnTe/Au detectors grown by the boron oxide encapsulated Vertical Bridgman technique
2016
Abstract In this work we report on the results of electrical characterization of new CdZnTe detectors grown by the Boron oxide encapsulated Vertical Bridgman technique (B-VB), currently produced at IMEM-CNR (Parma, Italy). The detectors, with gold electroless contacts, have different thicknesses (1 and 2.5 mm) and the same electrode layout, characterized by a central anode surrounded by a guard-ring electrode. Investigations on the charge transport mechanisms and the electrical contact properties, through the modeling of the measured current–voltage ( I – V ) curves, were performed. Generally, the detectors are characterized by low leakage currents at high bias voltages even at room tempera…