Search results for "OPTICS"
showing 10 items of 10033 documents
The impact of rear-view mirror distance and curvature on judgements relevant to road safety
2011
We report two experiments that investigate the impact of rear-view mirror distance and curvature on distance, spacing, and time-to-contact (TTC) judgements. The variation in mirror distance had a significant effect on TTC judgements, but only marginally influenced distance and spacing estimations. As mirror distance increased, TTC was overestimated, which is potentially dangerous. Control conditions with identical visual angles across different mirror distances revealed that effects were not solely caused by variation in visual angle. The impact of mirror curvature moderated the effect. While observers were unable to compensate for the mirror distance effect, they could do so for the distor…
Convex rear view mirrors compromise distance and time-to-contact judgements
2007
Convex rear view mirrors increasingly replace planar mirrors in automobiles. While increasing the field of view, convex mirrors are also taken to increase distance estimates and thereby reduce safety margins. However, this study failed to replicate systematic distance estimation errors in a real world setting. Whereas distance estimates were accurate on average, convex mirrors lead to significantly more variance in distance and spacing estimations. A second experiment explored the effect of mirrors on time-to-contact estimations, which had not been previously researched. Potential effects of display size were separated from effects caused by distortion in convex mirrors. Time-to-contact est…
Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability
2001
Abstract Purpose: To evaluate the intraobserver and interobserver variability in axial length (AL), anterior chamber depth (ACD), and corneal radius measurements using an optical biometry instrument based on partial coherence interferometry (PCI). Setting: Johannes Gutenberg University, Mainz, Germany. Methods: In this observational case series and interobserver reliability trial, 30 healthy, emmetropic to moderately myopic eyes of 15 volunteers were evaluated. The AL, ACD, and corneal radius were measured 20 times in 10 eyes by 1 observer to evaluate the intraobserver variability. To evaluate the interobserver variability, the measurements were taken in 20 eyes by 5 different observers. Me…
Interchangeability among five devices that measure anterior eye distances.
2014
The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…
Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer.
2020
To assess the repeatability of ocular biometric parameters using a high-resolution imaging device.74 healthy right eyes were included in this study. Five-repeated measurements were taken with ANTERION high-resolution swept-source optical coherence tomographer (SS-OCT) to measure: corneal thickness (central and at 2, 4 and 6-mm diameters), aqueous depth (AD), lens thickness (LT), anterior chamber volume (ACV), axial length (AL), and pupil (diameter and position). The intrasubject standard deviation (SWe have not found statistically significant differences between repeated measurements (p 0.05). The mean difference for corneal thickness was between -0.08 and 0.28 μm. For AD and LT was 0.004 …
Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system
2014
Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…
Repeatability of whole-cornea measurements using an anterior segment imaging device based on OCT and Placido-disk
2017
Current advances in refractive surgery require high accuracy of corneal measurements. We aim to evaluate the repeatability of topographic measurements using an integrated Placido disk - OCT device.Thirty right eyes of thirty healthy and young subjects were included. The topographic parameters of simulated keratometry, asphericity, minimum pachymetry, white-to-white distance, spherical aberration and corneal elevation were studied. Three measurements were taken by the same observer using the Visante omni device. The coefficient of repeatability (CoR), coefficient of variation (CoV) and intraclass correlation coefficient (ICC) were calculated to assess the repeatability. The Bland-Altman grap…
Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.
2012
Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…
Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Cohere…
2016
To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 periph…
The effect of aberrations on objectively assessed image quality and depth of focus
2017
The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…