Acute aortic dissection type A

2012

Abstract Background Acute aortic dissection type A (AADA) is a life-threatening vascular emergency. Clinical presentation ranges from pain related to the acute event, collapse due to aortic rupture or pericardial tamponade, or manifestations of organ or limb ischaemia. The purpose of this review was to clarify important clinical issues of AADA management, with a focus on diagnostic and therapeutic challenges. Methods Based on a MEDLINE search the latest literature on this topic was reviewed. Results from the German Registry for Acute Aortic Dissection Type A (GERAADA) are also described. Results Currently, the perioperative mortality rate of AADA is below 20 per cent, the rate of definitive…

Aortic archExtracorporeal Circulationmedicine.medical_specialtyAortic RupturePerioperative CareBrain IschemiaAortic aneurysmAneurysmHypothermia Inducedmedicine.arteryInternal medicinemedicineHumansAortic ruptureAortic dissectionbusiness.industryExtracorporeal circulationPrognosismedicine.diseaseAortic AneurysmSurgeryAortic DissectionAcute DiseaseCardiologySurgeryTamponadePresentation (obstetrics)businessBritish Journal of Surgery
researchProduct

Framework for Fluid-Structure Interaction Analysis of Aortic Coarctation Resulting From Proximal Protusion of Thoracic Aortic Stent Graft Into the Ar…

2011

Thoracic aortic stent grafts (TASG) are commonly used to repair aortic anomalies or diseases in a minimally-invasive fashion. One complication of TASG is collapse, whereby blood is unable to completely flow through the graft as intended. Most TASG collapses occur in the setting of endovascular repair of traumatic thoracic aortic transection, where a typically smaller diameter aorta of pediatric patients is repaired with a relatively larger diameter endograft designed to treat aneurysmal disease [1]. It is hypothesized that the poor apposition of the leading edge of the proximal stent graft to the lesser curvature of the aortic arch can result increased hemodynamic force at the leading side …

Aortic archmedicine.medical_specialtyAortabusiness.industrymedicine.medical_treatmentaorti failureSettore ING-IND/34 - Bioingegneria IndustrialeHemodynamicsStentCurvatures of the stomachSurgeryAppositionsurgical procedures operativemedicine.arteryInternal medicineOcclusioncardiovascular systemCardiologyMedicinebusinessComplicationASME 2011 Summer Bioengineering Conference, Parts A and B
researchProduct

Acute aortic dissection debut as STEMI: A case report

2014

Abstract We submit a case report of a 66-year-old male, with hypertension and family history of cerebrovascular disease, who was referred to our department for right-inferior STEMI. According to the current ESC (European Society of Cardiology) guidelines for the management of STEMI, the patient was conducted to the cath lab to perform primary PCI. Despite the identification of the culprit lesion we had many difficulties during the procedure of angioplasty, so we decided to perform aortography that showed a Stanford type A acute aortic dissection involving the ostium of right coronary artery causing the right-inferior STEMI. In the early phase of a STEMI, exclusion of the presence of aortic …

Aortic dissectionAcute coronary syndromemedicine.medical_specialtyAortographyCath labmedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentmedicine.diseaseOstiumsurgical procedures operativeInternal medicineAngioplastyRight coronary arterymedicine.arteryConventional PCImedicineCardiologycardiovascular diseasesbusinessJournal of Indian College of Cardiology
researchProduct

The Impact of Pre-Operative Malperfusion on Outcome in Acute Type A Aortic Dissection

2015

Abstract Background Malperfusion adversely affects outcomes in patients with acute type A aortic dissection, but reliable quantitative data are lacking. Objectives The aim of this study was to analyze the impact of various forms of malperfusion on early outcome. Methods A total of 2,137 consecutive patients enrolled in GERAADA (German Registry for Acute Aortic Dissection Type A) who underwent surgery between 2006 and 2010, of whom 717 (33.6%) had any kind of pre-operative malperfusion, were retrospectively analyzed. Results All-cause 30-day mortality was 16.9% and varied substantially according to the number of organ systems affected by malperfusion (none, 12.6%; 1 system, 21.3%; 2 systems,…

Aortic dissectionmedicine.medical_specialtySurgical strategyAdverse outcomesbusiness.industryIndependent predictormedicine.diseasePre operativeSurgeryAcute typeInternal medicinemedicineCardiologyIn patientbusinessCardiology and Cardiovascular MedicineOrgan systemJournal of the American College of Cardiology
researchProduct

Lessons Learned from the German Registry for Acute Aortic Dissection Type A (GERAADA) and Expectations for the Future

2014

The German Registry for Acute Aortic Dissection type A (GERAADA) is a prospective observational clinical multicenter registry that was launched in 2006. With more than 2,500 patients included from over 50 recruiting centers it is—to our knowledge—the most representative register for acute aortic dissection type A (AADA) currently available. We examined mortality and post-operative events as well as the influence of various pre- and intraoperative factors on these endpoints. Among patients registered, 30-day mortality is 15.9 %. 13.4 % of patients experienced postoperatively a new neurological deficit and a total of 10.5 % of patients suffered from permanent neurological impairment 30 days a…

Aortic dissectionmedicine.medical_specialtybusiness.industryGeneral surgeryPreoperative riskmedicine.diseaseAortic arch surgerylanguage.human_languageSurgeryGermanlanguageMedicineObservational studySources of errorbusinessNeurological impairmentNeurological deficit
researchProduct

Treatment of isolated ascending aortic aneurysm by off-pump epiaortic wrapping is safe and durable.

2016

OBJECTIVES: Isolated ascending aortic aneurysm (iAA) is usually treated by open graft repair requiring sternotomy, cardiopulmonary bypass (CPB) and cardioplegia. This approach carries significant mortality in older patients or those presenting with comorbidities. We report an original series of patients presenting with iAA and treated with epiaortic wrapping by using a synthetic mesh. This less invasive aortic repair technique allows reducing the aortic diameter to a predefined value and is performed without CPB. METHODS: Data from patients presenting with an iAA and treated with the wrapping technique (WT) by polypropylene/polyester mesh from November 2006 to July 2015 were collected. The …

Aortic valveMaleTime Factors030204 cardiovascular system & hematologySettore MED/22 - Chirurgia Vascolarelaw.inventionAortic aneurysm0302 clinical medicinelawAorta10042 Clinic for Diagnostic and Interventional RadiologyMedicine (all)Middle Aged2746 Surgerymedicine.anatomical_structureTreatment OutcomeWrapping girdlingFemaleCardiology and Cardiovascular MedicineVascular Surgical ProceduresPulmonary and Respiratory Medicinemedicine.medical_specialtyOffOff-pump610 Medicine & healthProsthesis Design2705 Cardiology and Cardiovascular MedicineGraft repair03 medical and health sciencesAneurysmBlood vessel prosthesismedicine.arteryAscending aortamedicineCardiopulmonary bypassHumansAortic valve insufficiency; Ascending aorta; Graft repair; Mesh (polypropylene/polyester); Off-pump; Wrapping girdling; Surgery; Medicine (all); Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular MedicineAgedRetrospective StudiesAortaAortic Aneurysm Thoracicbusiness.industryPerioperativemedicine.diseaseSternotomySurgeryBlood Vessel Prosthesis030228 respiratory systemAortic valve insufficiency2740 Pulmonary and Respiratory MedicinepumpSurgeryAscending aortaMesh (polypropylene/polyester)businessFollow-Up StudiesInteractive cardiovascular and thoracic surgery
researchProduct

Value and limitations of transesophageal echocardiography in the evaluation of aortic prostheses.

1993

Results of 34 transesophageal (TEE) studies in patients with suspected aortic prosthetic dysfunction were compared with transthoracic echocardiographic (TTE) results and to anatomic findings. Mass lesions noted at surgery (autopsy) were correctly described in 93% by TEE versus 43% by TTE. Abscesses were detected in 88% by TEE versus 18% by TTE. Bioprosthetic degeneration was visualized in 88% versus 38% and prosthetic obstruction correctly identified in 75% versus 50% by TEE and TTE, respectively. Anatomic aortic regurgitant lesions were identified in 96% by TEE versus 77% by TTE, whereas the correct origin was detected in 88% of cases by TEE versus 54% of cases by TTE. TEE provides valuabl…

Aortic valveMalemedicine.medical_specialtyProsthesis-Related InfectionsAortic Valve InsufficiencyAutopsySensitivity and SpecificityPostoperative ComplicationsPredictive Value of TestsmedicineHumansRadiology Nuclear Medicine and imagingIn patientProspective StudiesBioprosthesisbusiness.industryThrombosisbody regionsmedicine.anatomical_structureEchocardiographyAortic ValveHeart Valve ProsthesisFemaleRadiologyCardiology and Cardiovascular Medicinebusinesshuman activitiesJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct

Incidence, Predictive Factors, and Prognostic Impact of Silent Atrial Fibrillation After Transcatheter Aortic Valve Implantation.

2018

New onset atrial fibrillation post-transcatheter aortic valve implantation (TAVI) is common and is associated with adverse outcomes. However, silent atrial fibrillation (AF) is poorly documented in the context. This study sought to evaluate the incidence, predictive factors, and prognostic value of Silent AF post-TAVI. All the consecutive patients with TAVI were prospectively analyzed by continuous electrocardiogram monitoring≥48 hours after implantation. Silent AF was defined as asymptomatic episodes lasting at least 30 seconds. The population was divided into 3 groups: history of AF, no-AF, and silent AF. Among the 206 patients implanted with TAVI, 19 (16.1%) developed silent AF. Compared…

Aortic valveMalemedicine.medical_specialtyTime FactorsPopulationContext (language use)030204 cardiovascular system & hematologyAsymptomaticTranscatheter Aortic Valve Replacement03 medical and health sciencesElectrocardiography0302 clinical medicinePostoperative ComplicationsRisk FactorsInternal medicineAtrial FibrillationmedicineHumans030212 general & internal medicineProspective StudiesRegistriesProspective cohort studyeducationAged 80 and overeducation.field_of_studymedicine.diagnostic_testbusiness.industryIncidenceAtrial fibrillationAortic Valve Stenosismedicine.diseasePrognosismedicine.anatomical_structureAortic valve stenosisAortic ValveCardiologyFemaleFrancemedicine.symptomCardiology and Cardiovascular MedicinebusinessElectrocardiographyFollow-Up StudiesThe American journal of cardiology
researchProduct

Scenario optimization asset and liability modelling for individual investors

2006

We develop a scenario optimization model for asset and liability management of individual investors. The individual has a given level of initial wealth and a target goal to be reached within some time horizon. The individual must determine an asset allocation strategy so that the portfolio growth rate will be sufficient to reach the target. A scenario optimization model is formulated which maximizes the upside potential of the portfolio, with limits on the downside risk. Both upside and downside are measured vis- `a-vis the goal. The stochastic behavior of asset returns is captured through bootstrap simulation, and the simulation is embedded in the model to determine the optimal portfolio. …

Application portfolio managementComputer scienceLiabilityDownside riskGeneral Decision SciencesAsset allocationAsset and liability managementTime horizonManagement Science and Operations ResearchAsset returnBlack–Litterman modelMicroeconomicsReplicating portfolioPortfolioCapital asset pricing modelPost-modern portfolio theoryPortfolio optimizationPersonal asset allocation stochastic programmingBeta (finance)Upside potential ratio
researchProduct

Identifying the Unknown Content of an Ancient Egyptian Sealed Alabaster Vase from Kha and Merit’s Tomb Using Multiple Techniques and Multicomponent S…

2020

This article highlights the multianalytical study of exuded liquid from an ancient Egyptian sealed alabaster vase by Master's students in an applied chemistry for cultural heritage course. Master students are introduced to the field of Archaeometry that see the collaboration of experts in different areas of research such as conservators, curators of museums, physicists, chemists, etc. The sample is a residue exuded on the linen strip sealing an ancient Egyptian alabaster vase (inventory number S.8448) from the collection of the Museo Egizio in Turin (Italy). The students start to plan the noninvasive investigation by X-ray fluorescence (XRF), transmission electron microscopy (TEM), and ener…

Applications of ChemistrySample (material)Graduate Education/ResearchArt historyengineering.material01 natural sciencesAnalytical ChemistryEducationArchaeological scienceProblem Solving/Decision MakingReference standardsSettore CHIM/02 - Chimica Fisica010405 organic chemistry05 social sciences050301 educationGeneral ChemistryUpper-Division UndergraduateInventory Number0104 chemical sciencesCharacterization (materials science)Cultural heritageAlabasterCollaborative/Cooperative LearningengineeringBrown colorInstrumental Methods0503 educationInterdisciplinary/MultidisciplinaryJournal of Chemical Education
researchProduct