Search results for "Optical Coherence Tomography"

showing 10 items of 148 documents

Retinal nerve fibre layer thickness measurements in myopia by optical coherence tomography

2014

Aim: Our study aimed to evaluate through OCT, in a homogeneous group of subjects with various degrees of myopia, the macular thickness and that of the RNFL with the purpose of highlighting the possible presence of a correlation between their impairment and the degree of myopia. Material and Methods : 83 students of the Faculty of Medicine were considered, distinguished into 4 groups, 3 of them according to the degree of myopia and the last group (control group) was made of emmetropic subjects. Each subject was submitted to a determination of visual acuity and refractive defect and evaluation of the thickness of the macular fibres and of the retinal nerve fibre layer (RNFL) through OCT (Stra…

Materials sciencemedicine.diagnostic_testbusiness.industrySettore MED/30 - Malattie Apparato VisivoNerve fibre layerRetinalGeneral MedicineOphthalmologychemistry.chemical_compoundOpticschemistryOptical coherence tomographymedicineMyopiaRetinal nerve fibreOptical Coherence Tomographybusiness
researchProduct

Demonstration of remote optical measurement configuration that correlates to glucose concentration in blood

2010

An optical approach allowing the extraction and the separation of remote vibration sources has recently been proposed. The approach has also been applied for medical related applications as blood pressure and heart beats monitoring. In this paper we demonstrate its capability to monitor glucose concentration in blood stream. The technique is based on the tracking of temporal changes of reflected secondary speckle produced in human skin (wrist) when being illuminated by a laser beam. A temporal change in skin’s vibration profile generated due to blood pulsation is analyzed for estimating the glucose concentration. Experimental tests that were carried out in order to verify the proposed appro…

Materials scienceocis:(280.0280) Remote sensingmedicine.diagnostic_testNoninvasive Optical Diagnosticsbusiness.industryNear-infrared spectroscopyTracking (particle physics)Atomic and Molecular Physics and Opticsocis:(030.6140) SpeckleVibrationSpeckle patternremote sensingOpticsmedical optics and biotechnologyOptical coherence tomographyDigital image processingmedicineStage (hydrology)sense organsspecklebusinessLaser beamsocis:(170.0170) Medical optics and biotechnologyBiotechnologyBiomedical engineering
researchProduct

Combined multi-wavelength laser speckle contrast imaging and diffuse reflectance imaging for skin perfusion assessment

2019

Abstract Laser Speckle Contrast Imaging (LSCI) is a powerful low-cost method for visualization of flow, microcirculation and blood perfusion. Due to the fact that diseased and healthy tissues has different blood perfusion, LSCI can be a perspective tool for cancer diagnostics and discrimination between different types of tissues. Previously, multispectral diffuse reflectance imaging method for melanoma diagnostics has been introduced. In this work, multi-wavelength (532-, 655- and 850- nm) LSCI technique combined with hyperspectral camera and diffuse reflectance imaging method will be used for assessment of tissues with different skin perfusion properties. An in vivo experiment with occlusi…

Materials scienceskin cancerspeckle imagingmedicine.diagnostic_testhyperspectral imagingMultispectral imageHyperspectral imagingskin perfusionMicrocirculationSpeckle patternSDG 3 - Good Health and Well-beingSpeckleOptical coherence tomographymedicine/dk/atira/pure/sustainabledevelopmentgoals/good_health_and_well_beingSpeckle imagingDiffuse reflectionspeckle contrastPerfusionBiomedical engineeringNovel Biophotonics Techniques and Applications V
researchProduct

Immune-Mediated Desquamative Gingivitis and Optical Coherence Tomography Diagnostic Patterns: Clinical Implication from a Systematic Review

2021

Desquamative Gingivitis (DG) comprises heterogeneous clinical manifestations of numerous immune-mediated muco-cutaneous diseases. Optical Coherence Tomography (OCT) has been proposed as a valuable diagnostic support even if, to date, there are no standardized OCT-diagnostic patterns applicable to DGs. A systematic review was performed to detect existing data on in vivo OCT diagnostic patterns of the most common immune-mediated DGs (i.e., pemphigus vulgaris, mucous membrane pemphigoid and oral lichen planus). It has been found that OCT exhibits specific patterns that address the diagnosis of DG by pemphigus vulgaris (i.e., intraepithelial unilocular blister, reduced epithelial thickness, pre…

Medicine (General)medicine.medical_specialtyClinical Biochemistryoral mucous membrane pemphigoidR5-920Immune systemOptical coherence tomographyMedicineskin and connective tissue diseasesPathologicaloptical coherence tomographyintegumentary systemmedicine.diagnostic_testbusiness.industryBrief Reportoral pemphigus vulgarisPemphigus vulgarisOral pemphigus vulgarismedicine.diseaseDermatologydesquamative gingivitiseye diseasesDesquamative gingivitisstomatognathic diseasesMucous membrane pemphigoidDesquamative gingivitis Optical coherence tomography Oral mucous membrane pemphigoid Oral pemphigus vulgarisOral lichen planusbusinessDiagnostics
researchProduct

A MEMS array-type Mirau interferometer for swept-source OCT imaging with applications in dermatology

2017

In the frame the European project VIAMOS (www.viamos.eu) we developed a microsystem based on Mirau interferometry and applied for optical coherence tomography (OCT) imaging of living tissues. The objective is to benefit from advanced MOEMS technologies, enabling a new generation of miniature and low-cost instruments using the concept of the swept-source OCT (SS-OCT) microsystem based on spectrally tuned Mirau interferometry, into which a doublet of microlens matrices (4×4) and a wafer of movable reference mirrors are included, building the active Mirau interferometer.

Microelectromechanical systemsMicrolensMaterials sciencemedicine.diagnostic_testbusiness.industryMirau interferometerArray data type02 engineering and technology021001 nanoscience & nanotechnology01 natural sciences010309 opticsInterferometryOpticsOptical coherence tomographyMicrosystem0103 physical sciencesmedicineOptoelectronics0210 nano-technologybusiness2017 19th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS)
researchProduct

Evaluation of a Completely Robotized Neurosurgical Operating Microscope

2012

BACKGROUND Operating microscopes are essential for most neurosurgical procedures. Modern robot-assisted controls offer new possibilities, combining the advantages of conventional and automated systems. OBJECTIVE We evaluated the prototype of a completely robotized operating microscope with an integrated optical coherence tomography module. METHODS A standard operating microscope was fitted with motors and control instruments, with the manual control mode and balance preserved. In the robot mode, the microscope was steered by a remote control that could be fixed to a surgical instrument. External encoders and accelerometers tracked microscope movements. The microscope was additionally fitted…

MicrosurgeryMicroscopeSwineAccelerometerNeurosurgical Procedureslaw.inventionOptical coherence tomographylawTask Performance and AnalysisAnimalsHumansMedicineComputer visionAutofocusMicroscopymedicine.diagnostic_testbusiness.industryBrainEquipment DesignRoboticsSpineSurgery Computer-AssistedSurgical instrumentRobotSurgeryNeurology (clinical)Artificial intelligenceOperating microscopebusinessTomography Optical CoherenceCoherence (physics)Neurosurgery
researchProduct

NEURODEGENERATION IN MULTIPLE SCLEROSIS: COMPARISON BETWEEN CLINICAL, NEUROPSYCHOLOGICAL, MRI,AND OPTICAL COHERENCE TOMOGRAPHY PARAMETERS

2015

BACKGROUND AND OBJECTIVE Optical Coherence Tomography (OCT) enables rapid, non-invasive in vivo measurement of retinal nerve fiber layer (RNFL) thickness, reflecting axonal density within the optic nerve. There is still lack of concordance about the use of OCT in clinical routine as a surrogate measure of brain atrophy. Objective: To investigate the role of OCT as possible predictor of disability, cognitive impairment and neurodegeneration in Multiple Sclerosis (MS). MATERIAL AND METHODS We recruited patients affected by MS according to validated criteria at the Neurological Department of the University of Palermo. Patients performed Stratus OCT- 3 Zeiss to assess RNFL and GCS measurements.…

Multiple sclerosis Optical Coherence Tomography (OCT) Magnetic Resonance Imaging (MRI) atrophy neurodegenerationSettore MED/37 - NeuroradiologiaSettore MED/26 - NeurologiaSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore MED/42 - Igiene Generale E Applicata
researchProduct

High myopic patients with and without foveoschisis: morphological and functional characteristics.

2020

Purpose: Myopic foveoschisis (MF) is characterized by the splitting of the retinal layers in the fovea of patients with high myopia (HM). MF may progress into foveal detachment or macular hole formation with consequent loss of central vision. The aim of this study is to investigate morphological and functional changes of the macular region in myopic subjects with and without foveoschisis. Design: Observational, cross-sectional, comparative study. Methods: Forty-eight patients with HM and 24 healthy controls were evaluated by spectral domain-optical coherence tomography (SD-OCT), multifocal electroretinography (mfERG) and microperimetry (MP-1) tests to assess macular thickness, functionality…

Myopic foveoschisisMalemedicine.medical_specialtyFovea Centralisgenetic structuresRetinoschisisVisual AcuityRetinoschisisFoveoschisisRetina03 medical and health scienceschemistry.chemical_compound0302 clinical medicinePhysiology (medical)OphthalmologyHigh myopiaVitrectomyPost-hoc analysismedicineChi-square testElectroretinographyHumansMacular holePathological myopiabusiness.industryMultifocal electroretinography (mfERG)RetinalMiddle Agedmedicine.diseaseRetinal Perforationseye diseasesSensory SystemsSpectral domain-optical coherence tomography (SD-OCT)high myopia; microperimetry (MP-1); multifocal electroretinography (mfERG); myopic foveoschisis; pathological myopia; retinoschisis; spectral domain-optical coherence tomography (SD-OCT)OphthalmologyCross-Sectional StudieschemistryMyopia Degenerative030221 ophthalmology & optometryMicroperimetry (MP-1)Visual Field TestsFemalesense organsAnalysis of varianceVisual FieldsbusinessMicroperimetry030217 neurology & neurosurgeryTomography Optical CoherenceDocumenta ophthalmologica. Advances in ophthalmology
researchProduct

2020

We sought to determine the effects of the use of a Bioengineered Combo Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent (Combo® DTS) in patients with chronic total occlusion (CTO) by evaluating clinical outcomes and by performing an optical coherence tomography (OCT) analysis. We retrospectively analyzed data from 39 patients who had successfully undergone OCT-guided revascularization of a CTO being treated with a Combo® DTS. Clinical assessment, angiography (with quantitative coronary angiography analysis) and OCT examination were performed at baseline and at follow-up. The median follow-up period was 189 days, ranging from 157 to 615 days. At follow-up, revascularizatio…

Neointimamedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentStentGeneral Medicine030204 cardiovascular system & hematologyequipment and suppliesmedicine.diseaseRevascularization03 medical and health sciences0302 clinical medicineRestenosisOptical coherence tomographySirolimusCoronary stentAngiographymedicine030212 general & internal medicineRadiologybusinessmedicine.drugJournal of Clinical Medicine
researchProduct

Supercontinuum optimization for dual-soliton based light sources using genetic algorithms in a grid platform

2014

We present a numerical strategy to design fiber based dual pulse light sources exhibiting two predefined spectral peaks in the anomalous group velocity dispersion regime. The frequency conversion is based on the soliton fission and soliton self-frequency shift occurring during super- continuum generation. The optimization process is carried out by a genetic algorithm that provides the optimum input pulse parameters: wavelength, temporal width and peak power. This algorithm is implemented in a Grid platform in order to take advantage of distributed computing. These results are useful for optical coherence tomography applications where bell-shaped pulses located in the second near-infrared wi…

Nonlinear opticsLightFOS: Physical sciencesSoliton (optics)Pulse propagation and temporal solitonsOpticsIllumination designOptical coherence tomographyGenetic algorithmmedicineCIENCIAS DE LA COMPUTACION E INTELIGENCIA ARTIFICIALFiber Optic TechnologyScattering RadiationComputer SimulationElectrodesPhysicsPhotonsmedicine.diagnostic_testOptical coherence tomographybusiness.industryNonlinear opticsEquipment DesignAtomic and Molecular Physics and OpticsSupercontinuumPulse (physics)Power (physics)WavelengthComputer-Aided DesignbusinessAlgorithmsOptics (physics.optics)Physics - Optics
researchProduct