Search results for "Optical microscope"
showing 10 items of 157 documents
Charged colloidal model systems under confinement in slit geometry: a new setup for optical microscopic studies.
2013
A new experimental setup for optical microscopic studies of charged colloidal model systems under confinement between two flat walls is presented. The measurement cell consists of optically flat quartz substrates attached to piezo actuators. Those facilitate fast and flexible adjustment of the confining geometry. Optionally, the local cell height can be quantitatively controlled by in situ interferometric measurements. Proper choice of materials guarantees sufficient chemical inertia against contamination with salt ions. For efficient preparation of charged colloidal suspensions under strongly deionized conditions, the cell can be connected to a conventional pump circuit including a mixed b…
Near-field scanning optical microscopy to study nanometric structural details of LiNbO3 Zn-diffused channel waveguides
2008
A near-field scanning optical microscope (NSOM) is used to perform structural and optical characterization of the surface layer after Zn diffusion in a channel waveguide fabricated on lithium niobate. A theoretical approach has been developed in order to extract refractive index contrast from NSOM optical transmission measurements (illumination configuration). As a result, different solid phases present on the sample surface can be identified, such as ZnO and ZnNb2O6. They appear like submicrometric crystallites aligned along the domain wall direction, whose origin can be ascribed to some strain relaxation mechanism during the annealing process after Zn diffusion. Jose.Canet-Ferrer@uv.es
The Effect of Damage and Geometrical Variability on the Tensile Strength Distribution of Flax Fibers
2010
Natural fibers of plant origin are finding non-traditional applications as reinforcement of composite materials. The mechanical properties of fibers exhibit considerable scatter, being affected by the natural variability in plant as well as the damage accumulated during processing. For bast fibers, the primary damage mode is kink bands – zones of misaligned cellulose microfibrils extending across the fiber and oriented roughly perpendicularly to its axis. Another feature typical for natural fibers and contributing to the scatter of fiber strength is the variability of diameter along a fiber length and among the fibers. An analytical expression for the distribution of the longitudinal tensil…
Preparation of cholesteric particles from cellulose derivatives in a microfluidic setup
2011
A microfluidic setup was used to process lyotropic cholesteric liquid crystalline mixtures of cellulose derivatives into spherical particles in the micrometre scale. By the method of co-flowing injection, monodisperse droplets of the liquid crystal, dispersed in an aqueous carrier fluid, were prepared. Polymerization of the acrylic solvent with UV-light fixed the orientation obtained by the flowing motion. The resulting particles were characterized by polarizing optical microscopy.
FIMic: design for ultimate 3D-integral microscopy of in-vivo biological samples
2018
In this work, Fourier integral microscope (FIMic), an ultimate design of 3D-integral microscopy, is presented. By placing a multiplexing microlens array at the aperture stop of the microscope objective of the host microscope, FIMic shows extended depth of field and enhanced lateral resolution in comparison with regular integral microscopy. As FIMic directly produces a set of orthographic views of the 3D-micrometer-sized sample, it is suitable for real-time imaging. Following regular integral-imaging reconstruction algorithms, a 2.75-fold enhanced depth of field and [Formula: see text]-time better spatial resolution in comparison with conventional integral microscopy is reported. Our claims …
Fast Axial-Scanning Widefield Microscopy With Constant Magnification and Resolution
2015
In this paper, we propose the use of electrically-addressable lens devices for performing fast non-mechanical axial scanning when imaging three-dimensional samples. This non-mechanical method can be implemented in any commercial microscope. The approach is based on the insertion of the tunable lens at the aperture stop of the microscope objective. By tuning the voltage, a stack of depth images of 3D specimens can be captured in real time and with constant magnification and resolution. The main advantage of our technique is the possibility of performing fast axial scanning free of mechanical vibrations.
Nanostructured metal/oxide coatings
2007
Al based nanocomposite coatings on Cu and glass substrates were obtained in the conditions of severe shear stresses by deformation scheme similar to that of friction. Structure, composition and micromechanical properties were investigated using AFM, XRD, SIMS, electron, optical microscopy and precision microindentation techniques. Coatings are characterized by the high microhardness and good adhesion to the substrates. This is determined by the formation of nanostructured Al-oxide composite stabilized by the presence of oxidized interlayers, which are barriers for the grain growth and intermetallic phase formation. The annealing in vacuum leads to the development of oxygen redistribution pr…
Dynamics of paramagnetic nanostructured rods under rotating field
2011
International audience; The dynamical rotational behavior of magnetic nanostructured rods based on the auto-association of maghemite nanoparticles and block-copolymers is probed by optical microscopy under rotating fields i n a s imple l iquid. The reorientation of the rods by a field rotated by 90° is first studied. The measured relaxation is characteristic of param-agnetic objects. Under a stationnary rotating field, a synchronous rotational regime is observed at low field frequency. Above a frequency threshold which scales as H^2 , the dynamics becomes asynchronous with back-and-forth rotations. These behaviors are well predicted by the presented model.
Subwavelength mapping of surface photonic states
2003
We show that the spectral tailoring of optical local density of states (LDOS) may be achieved by lithographically designed nanostructures and that the subwavelength mapping of the spectral variation of the optical LDOS is feasible by varying the driving frequency of the effective dipole used in an illumination mode scanning near-field optical microscope.
Near-field study with a photon scanning tunneling microscope: Comparison between dielectric nanostructure and metallic nanostructure
2007
Abstract Scanning near-field optical microscopy (SNOM) integrates standard optical methods with scanning probe microscopy (SPM) techniques allowing to collect optical information with resolution well beyond the diffraction limit. We study the influence on image formation of several parameters in scanning near-field microscopy. The numerical calculations have been carried out using the differential method. We investigate a 2D-PSTM configuration with a dielectric rectangular object. We will focus on the collection type SNOM in a constant height scanning mode. Various oscillation patterns are observed from both sides of the nanostructure, which we interpret as interference between the diffract…