Search results for "Optics and photonics"

showing 10 items of 84 documents

Comparison of visual and refractive results of Toric Implantable Collamer Lens with bioptics for myopic astigmatism.

2013

PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, adverse events, safety, and efficacy were evaluated 12 months postoperatively. RESULTS: At 12 months postoperatively, the mean spherical equivalent was -0.15 ± 0.36 diopters (D) in the TICL group and -0.08 ± 0.26 D in the bioptics group (p = 0.099). Sixty-six …

AdultMalemedicine.medical_specialtyBiopticsOptics and PhotonicsPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentImplantable Collamer Lens (ICL)Keratomileusis Laser In SituVisual AcuityKeratomileusisAstigmatismExcimerPhakic intraocular lensRefraction OcularPhotorefractive KeratectomyCellular and Molecular NeuroscienceYoung AdultOpticsBioptics (surgery)Lens Implantation IntraocularOphthalmologymedicineMyopiaHumansDioptreImplantable collamer lensScience & TechnologyExcimer laserbusiness.industryAstigmatismMiddle Agedmedicine.diseaseSensory SystemsPhotorefractive keratectomyeye diseasesOphthalmologyImplantable Collamer LensTreatment OutcomeFemalebusinessGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
researchProduct

Optical and Visual Quality of the Visian Implantable Collamer Lens Using an Adaptive-Optics Visual Simulator

2013

To evaluate visual and optical quality of the implantable collamer lens for different powers and sizes of incision surgery.Prospective study in humans.An adaptive optics visual simulator was used to measure 3 powers of implantable collamer lenses and simulate the implantable collamer lens wavefront aberration's pattern for small- and large-incision surgery. Visual acuity (VA) and contrast sensitivity were measured in 11 observers for 3- and 5-mm pupils. Modulation transfer function, point spread function, and Strehl ratio were calculated.At 3 mm pupil, no statistically significant differences were found between both incision sizes for any implantable collamer lens power, except for -15 diop…

AdultMicrosurgeryOptics and PhotonicsPhakic Intraocular LensesVisual acuityAdolescentgenetic structuresComputer sciencemedia_common.quotation_subjectVisual AcuityPhakic intraocular lensPupilYoung AdultLens Implantation IntraocularOptical transfer functionmedicineHumansContrast (vision)Prospective StudiesAdaptive opticsVision OcularSimulationDioptremedia_commonAberrometryStrehl ratioeye diseasesRefractive Surgical ProceduresOphthalmologysense organsmedicine.symptomAmerican Journal of Ophthalmology
researchProduct

The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing

2018

Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…

AdultOptics and PhotonicsOriginal articleCorneal Wavefront AberrationVisual AcuityStarburstDiameter pupilRefraction Ocular050105 experimental psychology03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyError refractivoVisión nocturnaAberración esféricalcsh:QC350-467Humans0501 psychology and cognitive sciencesSpherical aberrationNight visionPhysicsResoluciónRefractive error05 social sciencesMiddle AgedRefractive ErrorsDetecciónDetectionlcsh:RE1-994030221 ophthalmology & optometryResolutionHumanitieslcsh:Optics. LightPhotic StimulationOptometryJournal of Optometry
researchProduct

Bis(oxazoline) Lewis Acid Catalyzed Aldol Reactions of PyridineN-Oxide Aldehydes—Synthesis of Optically Active 2-(1-Hydroxyalkyl)pyridine Derivatives…

2006

A new, short, and simplified procedure for the synthesis of optically active pyridine derivatives from pro-chiral pyridine-N-oxides is presented. The catalytic and asymmetric Mukaiyama aldol reaction between ketene silyl acetals and 1-oxypyridine-2-carbaldehyde derivatives catalyzed by chiral copper(II)-bis(oxazoline) complexes gave optically active 2-(hydroxyalkyl)- and 2-(anti-1,2-dihydroxyalkyl)pyridine derivatives in good yields and diastereoselectivities, and in excellent enantioselectivities-up to 99 % enantiomeric excess. As a synthetic application of the developed method, a full account for the asymmetric total synthesis of a nonnatural indolizine alkaloid is provided.

AldehydesOptics and PhotonicsPyridinesChemistryOrganic ChemistryIndolizinesEnantioselective synthesisTotal synthesisPyridine-N-oxideStereoisomerismGeneral ChemistryOxazolineCatalysisCyclic N-OxidesChemistrychemistry.chemical_compoundAlkaloidsAldol reactionPyridineOrganic chemistryIndolizineEnantiomeric excessAcidsChemistry - A European Journal
researchProduct

Image quality with multifocal intraocular lenses and the effect of pupil size

2007

Purpose To analyze the image quality with a refractive and 2 hybrid refractive–diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods This study evaluated 4 IOLs: the hybrid refractive–diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Sci…

Artificial corneaOptics and PhotonicsImage qualitymedicine.medical_treatmentIntraocular lensProsthesis DesignModels BiologicalPupilContrast SensitivityOpticsOptical transfer functionmedicineHumansImaging scienceMathematicsLenses IntraocularFourier Analysisbusiness.industryPupil sizePupilMultifocal intraocular lensSensory SystemsOphthalmologyOptometrySurgerybusinessJournal of Cataract and Refractive Surgery
researchProduct

Imaging Quality of Bifocal Piggyback Intraocular Lens versus ReSTOR and TECNIS Multifocal Lenses

2009

Purpose The imaging quality provided by a piggyback integrated by a monofocal intraocular lens (IOL) + a bifocal IOL of zero power and +3.75 diopters of addition is compared with the optics quality of a simple multifocal IOL of the same power and addition. Methods The imaging quality was evaluated by determining the modulation transfer function (MTF), using an artificial eye simulating in vivo conditions of the anterior chamber, including an artificial cornea and a wet cell containing physiologic solution where the IOL was positioned. The MTFs of the bifocal piggyback for near and distance vision were measured, with pupil diameters of 3 and 5 mm, and compared with the MTFs of an equivalent …

Artificial corneaOptics and Photonicsmedicine.medical_specialtybusiness.product_categoryMaterials sciencemedicine.medical_treatmentVisual AcuityIntraocular lensEyeRefraction OcularPupil03 medical and health sciences0302 clinical medicineOptical transfer functionOphthalmologymedicineHumansMultifocal lensesDioptreLenses IntraocularDepth PerceptionStrehl ratioGeneral MedicineModels TheoreticalOphthalmologyImaging quality030221 ophthalmology & optometryArtificial Organsbusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Properties of erythrocyte light refraction in diabetic patients.

2001

Since hyperglycaemia changes the erythrocyte cell membrane fluidity and impairs cell deformity, our goal was to characterize hemoglobin and red blood cell (RBC) light refractive property changes in diabetic patients. Microscopic investigation was carried out on intact and fixed RBCs. To determine the refractive index (RI): smears of peripheral blood were air dried and fixed for 3 min in methanol. Mixtures of polyvinylpyrolidine and buffer of different pH (1:1) were used as embedding media. Intact RBCs were mixed with a buffered embedding medium, placed on a slide and overlaid with a coverslip. Interference microscopy was used for RI measurements at 18 different pH (pH=2-13). The results sho…

Blood GlucoseOptics and PhotonicsErythrocytesLightBiomedical EngineeringIn Vitro TechniquesBiomaterialsOpticsmedicineDiabetes MellitusHumansScattering RadiationMicroscopy InterferenceChromatographyChemistrybusiness.industryHydrogen-Ion ConcentrationRefractionAtomic and Molecular Physics and OpticsPeripheral bloodElectronic Optical and Magnetic MaterialsRed blood cellmedicine.anatomical_structureCase-Control StudiesHyperglycemiaHemoglobinMicroscopy PolarizationbusinessJournal of biomedical optics
researchProduct

Noncontact speckle-based optical sensor for detection of glucose concentration using magneto-optic effect

2016

We experimentally verify a speckle-based technique for noncontact measurement of glucose concentration in the bloodstream. The final device is intended to be a single wristwatch-style device containing a laser, a camera, and an alternating current (ac) electromagnet generated by a solenoid. The experiments presented are performed in vitro as proof of the concept. When a glucose substance is inserted into a solenoid generating an ac magnetic field, it exhibits Faraday rotation, which affects the temporal changes of the secondary speckle pattern distributions. The temporal frequency resulting from the ac magnetic field was found to have a lock-in amplification role, which increased the observ…

Blood GlucoseOptics and PhotonicsMaterials scienceLightRotationBiomedical EngineeringSolenoid01 natural sciencesMagneto-optic effectlaw.invention010309 opticsBiomaterialssymbols.namesakeSpeckle patternOpticslaw0103 physical sciencesFaraday effectHumansElectromagnetbusiness.industryLasers010401 analytical chemistryLaserAtomic and Molecular Physics and Optics0104 chemical sciencesElectronic Optical and Magnetic MaterialsMagnetic fieldMagnetssymbolsAlternating currentbusinessBlood Chemical AnalysisJournal of Biomedical Optics
researchProduct

Short hydrogen bonds enhance nonaromatic protein-related fluorescence

2021

Significance Intrinsic fluorescence of nonaromatic amino acids is a puzzling phenomenon with an enormous potential in biophotonic applications. The physical origins of this effect, however, remain elusive. Herein, we demonstrate how specific hydrogen bond networks can modulate fluorescence. We highlight the key role played by short hydrogen bonds, present in the protein structure, on the ensuing fluorescence. We provide detailed experimental and molecular evidence to explain these unusual nonaromatic optical properties. Our findings should benefit the design of novel optically active biomaterials for applications in biosensing and imaging.

Chemical transformationOptics and PhotonicsGlutamineIntrinsic fluorescenceMolecular Dynamics SimulationPhotochemistryFluorescenceAb initio molecular dynamicsAmmoniaHumansSingle amino acidshort hydrogen bondDensity Functional TheoryMultidisciplinaryHydrogen bondChemistryintrinsic fluorescenceultraviolet fluorescenceHydrogen BondingConical intersectionFluorescenceBiophysics and Computational BiologyExcited statePhysical Sciences408PeptidesProceedings of the National Academy of Sciences of the United States of America
researchProduct

Refinement of a structural model of a pigment-protein complex by accurate optical line shape theory and experiments.

2007

Time-local and time-nonlocal theories are used in combination with optical spectroscopy to characterize the water-soluble chlorophyll binding protein complex (WSCP) from cauliflower. The recombinant cauliflower WSCP complexes reconstituted with either chlorophyll b (Chl b) or Chl a/Chl b mixtures are characterized by absorption spectroscopy at 77 and 298 K and circular dichroism at 298 K. On the basis of the analysis of these spectra and spectra reported for recombinant WSCP reconstituted with Chl a only (Hughes, J. L.; Razeghifard, R.; Logue, M.; Oakley, A.; Wydrzynski, T.; Krausz, E. J. Am. Chem. Soc. U.S.A. 2006, 128, 3649), the "open-sandwich" model proposed for the structure of the pig…

Chlorophyll bChlorophyllModels MolecularCircular dichroismOptics and PhotonicsAbsorption spectroscopyChemistryDimerExcitonChlorophyll ACircular DichroismSpectrum AnalysisStatic ElectricityLight-Harvesting Protein ComplexesBrassicaSpectral lineSurfaces Coatings and Filmschemistry.chemical_compoundCrystallographyKineticsModels ChemicalMaterials ChemistryChlorophyll bindingPhysical and Theoretical ChemistrySpectroscopyThe journal of physical chemistry. B
researchProduct