Search results for "Optometry"
showing 10 items of 812 documents
Accuracy and accommodation capability of a handheld autorefractor
2000
Purpose: To determine the accuracy of measurement by the Nikon Retinomax handheld autorefractor and its ability to relax accommodation. Setting: Pediatric Section, Department of Ophthalmology, University of Mainz, Germany. Methods: To perform a series of comparative measurements, autorefractor readings were obtained on healthy young adults (students) and on children aged 2 to 12 years. The autorefractor readings were compared with subjective refractions of the young adults and with cycloplegic retinoscopy of the children. Results: In adults, the accuracy of the handheld autorefractor measurements was comparable to that of conventional tabletop autorefractors. In children, the autorefractor …
Amplitude, Latency, and Peak Velocity in Accommodation and Disaccommodation Dynamics
2017
The aim of this work was to ascertain whether there are differences in amplitude, latency, and peak velocity of accommodation and disaccommodation responses when different analysis strategies are used to compute them, such as fitting different functions to the responses or for smoothing them prior to computing the parameters. Accommodation and disaccommodation responses from four subjects to pulse changes in demand were recorded by means of aberrometry. Three different strategies were followed to analyze such responses: fitting an exponential function to the experimental data; fitting a Boltzmann sigmoid function to the data; and smoothing the data. Amplitude, latency, and peak velocity of …
Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
2019
ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significan…
Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes
2003
Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…
Spontaneous Resolution of Delayed Suprachoroidal Hemorrhage in the Single Eye Following Needling in Congenital Glaucoma
2017
Suprachoroidal hemorrhage (SCH) is a rare, but potentially vision-threatening event with poor long-term visual prognosis. At present, there is disagreement whether surgical intervention or conservative treatment is superior in the management. We report on a case of spontaneous resolution of severe SCH after needling procedure in the only eye of a young patient with congenital glaucoma.A 43-year-old woman with congenital glaucoma was scheduled for bleb needling in her only eye. Preoperative best-corrected visual acuity was 20/40 and intraocular pressure 20 mm Hg. On the third postoperative day, she developed a massive delayed SCH with appositional (kissing) choroidal bullae and visual acuity…
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…
Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.
2013
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…
Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK
2018
ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…