Search results for "Optometry"
showing 10 items of 812 documents
Effect of Color on Contrast Sensitivity with Two Different Accommodative Stimuli
1993
We studied the influence of color and accommodation on the contrast sensitivity function (CSF). At the same time, we measured the effect of axial chromatic aberration (ACA) on the CSF. The CSF's of two observers were determined using red, green, blue, and white light, at 5- and 0.5-m viewing distances. At 5 m the CSF's were measured with natural vision and also with lenses which compensated the ACA. Results show that the effect of ACA on the CSF is to reduce the sensitivity to blue with respect to the red. The difference in sensitivity between these two colors is between 50 and 150% and varies with the frequency and the subject. When the ACA is compensated the influence of the color on the …
Visual Acuity in Simple Myopic Astigmatism: Influence of Cylinder Axis
2006
Purpose. The relationship between astigmatic refractive errors and their associated visual acuity has been studied in recent years in the context of refractive power space. The influence of the axis of astigmatism remains a matter of controversy. Our goal in this study is to provide additional experimental evidence to clarify this subject. The influence of the simulated axis orientation was compared with other factors that affect visual acuity such as the particular design of the test and the differences between eyes. Methods. Simple myopic astigmatism from 0 to 3.00 D, in steps of 0.25 D, and with five different axes between 0° and 90°, were simulated on four healthy eyes of young observer…
Impact of the line of sight on toric phakic intraocular lenses for hyperopia
2003
We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.
Blue-yellow deficiencies in young moderate smokers.
2021
Purpose To evaluate whether tobacco affects color vision in young moderate smokers. Methods Chromatic mechanisms of 13 moderate smokers (10–20 cigarettes/day and at least 5 years smoking) and 17 non-smokers in the 18–35 age range were assessed with the Farnsworth-Munsell 100-hue (FM100h) test and short wavelength automated perimetry (SWAP). Results FM100h Total Error Scores (TES) were higher for smokers, and although differences were not significant (p = 0.14), a linear model with principal component analysis was able to explain 95% of the variance in TES and red-green partial error scores, though not in blue-yellow partial error scores (p = 0.07), using the number of years as smokers and t…
Optical Coherence Tomography Angiography of Optic Disc in Eyes With Primary Open-angle Glaucoma and Normal-tension Glaucoma.
2019
PURPOSE To examine vessel density (VD) properties of the optic nerve head in eyes with ocular hypertension (OHT), high-tension glaucoma (HTG), and normal-tension glaucoma (NTG) and to evaluate associations on structural parameters of retinal nerve fiber layer (RNFL). METHODS Three groups of patients with OHT (n=15), HTG (n=36), and NTG (n=22), and a healthy control group (n=23) were included in this study. Peripapillary VD and optic disc flow area were measured using optical coherence tomography angiography, and peripapillary RNFL (pRNFL) thickness was determined. Global and sectoral analysis of optic nerve head vasculature and pRNFL thickness were measured. RESULTS Glaucomatous eyes had lo…
Avaliação da resposta de acomodação após tarefas visuais próximas usando diferentes dispositivos eletrônicos portáteis
2015
ABSTRACT Purpose: To assess the accommodation response after short reading periods using a tablet and a smartphone as well as determine potential differences in the accommodation response at various stimulus vergences using a Hartmann- Shack aberrometer. Methods: Eighteen healthy subjects with astigmatism of less than 1 D, corrected visual acuity of 20/20 or better, and normal findings in an ophthalmic examination were enrolled. Accommodation responses were obtained under three different conditions: accommodation system of the eye relaxed and visually stressed with a tablet and an smartphone for 10 min, at a distance of 0.25 m from the subject's eyes. Three measurements of accommodation res…
Quantitative corneal anatomy in emmetropic subjects.
2006
PURPOSE Currently there is little information available about the corneal thickness values of healthy emmetropic subjects. Therefore, the authors decided to analyze the corneal thickness in healthy emmetropic subjects. METHODS The authors analyzed the difference in thickness values between the thinnest corneal site and the central and paracentral cornea in 124 eyes of 124 healthy emmetropic white subjects. RESULTS The mean difference between the thinnest site of the cornea and the thickness values obtained in the areas analyzed was as follows: 12+/-6 microm center; 140+/-19 microm superonasal; 133+/-23 microm nasal; 117+/-26 microm inferonasal; 122+/-19 microm superotemporal ; 89+/-22 micro…
Monocular versus binocular pupillometry.
2004
Purpose To quantify differences between monocular and binocular pupil size measurement under scotopic and mesopic conditions. Setting Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. Methods Computerized dynamic pupillometry (P2000 SA, Procyon Instruments Ltd.) was used at 3 illumination levels: scotopic at 0.03 lux, mesopic low at 0.82 lux, and mesopic high at 6.4 lux. One hundred forty eyes of 70 healthy volunteers without ocular pathology were examined. The subjects were divided into 2 groups. In the first group, the pupil diameter was measured binocularly first. In the secon…
Simulating Images Seen by Patients with Inhomogeneous Sensitivity Losses
2012
PURPOSE We aim to simulate how colored images are perceived by subjects with local achromatic and chromatic contrast sensitivity losses in the visual field (VF). METHODS The spatiochromatic corresponding pair algorithm, introduced in a previous article (J Opt Soc Am (A) 2004;21:176-186), has been implemented with a linear model of the visual system. Spatial information is processed separately by the chromatic and achromatic mechanisms by means of a multiscale model, with sensors selective to frequency, orientation, and spatial position, whose mechanism-dependent relative weights change with the spatial location of the image. These weights have been obtained from perimetric data from a patie…
Optic disc drusen in tilted disc
2017
Purpose To investigate if a congenital anomaly of the head of the optic nerve like such as tilted disc can be a risk factor for the development of optic disc drusen. Methods The study was performed retrospectively on the files of 47 patients with optic disc drusen. The diagnosis was confirmed by fluorescein angiography and B-scan ultrasonography. The authors examined the fundus photographs and the fluorescein angiographies of these patients looking for the presence of tilted discs. Results Two of the 47 patients with optic nerve drusen had tilted discs as well, about twice the expected rate. Both cases presented a parapapillary hemorrhage. Conclusions The concomitant presence of tilted disc…