Search results for "Oxygen"
showing 10 items of 3640 documents
The Greenland shark Somniosus microcephalus—Hemoglobins and ligand-binding properties
2017
A large amount of data is currently available on the adaptive mechanisms of polar bony fish hemoglobins, but structural information on those of cartilaginous species is scarce. This study presents the first characterisation of the hemoglobin system of one of the longest-living vertebrate species (392 +/- 120 years), the Arctic shark Somniosus microcephalus. Three major hemoglobins are found in its red blood cells and are made of two copies of the same a globin combined with two copies of three very similar beta subunits. The three hemoglobins show very similar oxygenation and carbonylation properties, which are unaffected by urea, a very important compound in marine elasmobranch physiology.…
Effect of space charge on the negative oxygen flux during reactive sputtering
2017
Negative ions often play a distinctive role in the phase formation during reactive sputter deposition. The path of these high energetic ions is often assumed to be straight. In this paper, it is shown that in the context of reactive magnetron sputtering space charge effects are decisive for the energetic negative ion trajectories. To investigate the effect of space charge spreading, reactive magnetron sputter experiments were performed in compound mode with target materials that are expected to have a high secondary ion emission yield (MgO and CeO2). By the combination of energy flux measurements, and simulations, a quantitative value for the negative oxygen ion yield can be derived.
Evolution of the microstructure of sputter deposited TaAlON thin films with increasing oxygen partial pressure
2021
Abstract Recently, quaternary oxynitrides of transition metals and aluminum have attracted increasing interest due to their tunable properties. Within the present work, a series of TaAl(O)N films was sputter deposited using constant nitrogen and varying oxygen partial pressures. The films were grown from single element Ta and Al targets. The deposition parameters were adjusted to obtain a Ta/Al atomic ratio of ~50/50 for the oxygen-free film and were held constant for the following depositions, with the exception of the increasing oxygen partial pressure and compensatory decreasing argon partial pressure. Elastic recoil detection analysis revealed oxygen contents of up to ~26 at.%, while th…
First principles simulations on migration paths of oxygen interstitials in magnesium aluminate spinel
2018
This study has been carried out within the framework of the EURO fusion Consortium and has been provided funding from the Euratom research and training program 2014–2018 under grant agreement No. 633053. The authors are indebted to A.I. Popov, A.C. Lushchik and R. Vila for stimulating discussions. Technical assistance from O. Lisovski is appreciated too. The views and opinions expressed herein do not necessarily reflect those of the European Commission. Calculations have been performed using Marconi supercomputer system based in Italy at CINECA Supercomputing Centre.
Epitaxial growth of perovskite oxide films facilitated by oxygen vacancies
2021
The authors would like to thank P. Yudin for valuable discussions, N. Nepomniashchaia for VASE studies, and S. Cichon for XPS analysis. The authors acknowledge support from the Czech Science Foundation (Grant No. 19-09671S), the European Structural and Investment Funds and the Ministry of Education, Youth and Sports of the Czech Republic through Programme ‘‘Research, Development and Education’’ (Project No. SOLID21 CZ.02.1.01/0.0/0.0/16-019/0000760), and ERA NET project Sun2Chem (E. K. and L. R.). Calculations have been done on the LASC Cluster in the ISSP UL.
XUV diagnostic to monitor H-like emission from B, C, N, and O for the W7-X stellarator
2019
The “C/O Monitor” system for the Wendelstein 7-X (W7-X) stellarator is a dedicated spectrometer with high throughput and high time resolution (order of 1 ms) for fast monitoring of content of low-Z impurities in the plasma. The observed spectral lines are fixed to Lyman-α lines of H-like atoms of carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm), and boron (4.9 nm). The quality of the wall condition will be monitored by the measurements of oxygen being released from the walls during the experiments. The strong presence of carbon is an indication for enhanced plasma-wall interaction or overload of plasma facing components. The presence of nitrogen (together with oxygen) may indicate a poss…
Evaluation and Comparison of Novel Precursors for Atomic Layer Deposition of Nb2O5 Thin Films
2012
Atomic layer deposition (ALD) of Nb2O5 thin films was studied using three novel precursors, namely, tBuN═Nb(NEt2)3, tBuN═Nb(NMeEt)3, and tamylN═Nb(OtBu)3. These precursors are liquid at room temperature, present good volatility, and are reactive toward both water and ozone as the oxygen sources. The deposition temperature was varied from 150 to 375 °C. ALD-type saturative growth modes were confirmed at 275 °C for tBuN═Nb(NEt2)3 and tBuN═Nb(NMeEt)3 together with both oxygen sources. Constant growth rate was observed between a temperature regions of 150 and 325 °C. By contrast, amylN═Nb(OtBu)3 exhibited limited thermal stability and thus a saturative growth mode was not achieved. All films we…
Thermal annealing of radiation damage produced by swift 132Xe ions in MgO single crystals
2020
Abstract The annealing kinetics of the electron-type F+ and F color centers in highly pure MgO single crystals irradiated by 0.23-GeV 132Xe ions with fluences covering three orders of magnitude (Φ = 5 × 1011 –3.3 × 1014 ions/cm2) are studied experimentally via dependence of the optical absorption on preheating temperature. The annealing data are analyzed in terms of the diffusion-controlled bimolecular reactions between F-type centers and complementary interstitial oxygen ions. The behavior of the main kinetic parameters – the migration energies and pre-exponential factors – for different irradiation fluences is discussed and compared with that for other wide-gap binary materials from previ…
Estimation of Photon Flux of the Oxygen Lyman-alpha Line Emitted from the W7-X Plasmas
2020
The low-Z impurities of the magnetic confined fusion plasmas can provide important information about the wall condition and plasma–wall interactions. In order to accomplish this aim, a special spectrometer called “C/O Monitor” was designed for the W7-X experiment. This system is dedicated to measure Lyman-α transitions of four low-Z impurities: carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm) and boron (4.9 nm). It is a high throughput and high time resolution spectrometer which allows to measure the line intensities evolution of indicated elements including information of the background (continuum). The designed spectrometer consists of two vacuum chambers positioned nearly horizontally…
Photochemically Produced Singlet Oxygen: Applications and Perspectives
2018
This Review aims to provide early stage researchers with an updated guide to applications of photochemically produced singlet oxygen and, at the same time, widen the experienced researcher's perspectives in a holistic approach to singlet oxygen chemistry. Without being exhaustive, literature between 2010 and early 2018 has been surveyed by focusing on a critical evaluation of new knowledge and applications. After an introductory section concerning singlet oxygen production, detection, and interactions with biological systems, subsequent sections describe current applications of singlet-oxygen-enabled technology. Besides strictly chemical synthesis applications, attention has been given to t…