Search results for "PIXE"
showing 10 items of 428 documents
The MuPix System-on-Chip for the Mu3e Experiment
2016
Nuclear instruments & methods in physics research / A 845, 194 - 198 (2016). doi:10.1016/j.nima.2016.06.095
Technical design of the phase I Mu3e experiment
2021
Nuclear instruments & methods in physics research / A 1014, 165679 (2021). doi:10.1016/j.nima.2021.165679
Radiation hard monolithic CMOS sensors with small electrodes for High Luminosity LHC
2019
Abstract The upgrade of the tracking detectors for the High Luminosity-LHC (HL-LHC) requires the development of novel radiation hard silicon sensors. The development of Depleted Monolithic Active Pixel Sensors targets the replacement of hybrid pixel detectors with radiation hard monolithic CMOS sensors. We designed, manufactured and tested radiation hard monolithic CMOS sensors in the TowerJazz 180 nm CMOS imaging technology with small electrodes pixel designs. These designs can achieve pixel pitches well below current hybrid pixel sensors (typically 50 × 50 μ m ) for improved spatial resolution. Monolithic sensors in our design allow to reduce multiple scattering by thinning to a total si…
Room-Temperature X-ray response of cadmium-zinc-Telluride pixel detectors grown by the vertical Bridgman technique
2020
In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation o…
The Belle II vertex detector integration
2019
Belle II DEPFET, PXD, and SVD Collaborations: et al.
Studies for low mass, large area monolithic silicon pixel detector modules using the MALTA CMOS pixel chip
2021
Abstract The MALTA monolithic silicon pixel sensors have been used to study dicing and thinning of monolithic silicon pixel detectors for large area and low mass modules. Dicing as close as possible to the active circuitry will allow to build modules with very narrow inactive regions between the sensors. Inactive edge regions of less than 5 μ m to the electronic circuitry could be achieved for 100 μ m thick sensors. The MALTA chip (Cardella et al., 2019) also offers the possibility to transfer data and power directly from chip to chip. Tests have been carried out connecting two MALTA chips directly using ultrasonic wedge wire bonding. Results from lab tests show that the data accumulated in…
Efficiency and timing performance of the MuPix7 high-voltage monolithic active pixel sensor
2018
The MuPix7 is a prototype high voltage monolithic active pixel sensor with 103 times 80 um2 pixels thinned to 64 um and incorporating the complete read-out circuitry including a 1.25 Gbit/s differential data link. Using data taken at the DESY electron test beam, we demonstrate an efficiency of 99.3% and a time resolution of 14 ns. The efficiency and time resolution are studied with sub-pixel resolution and reproduced in simulations.
Tang dynasty (618-907) bowl measured with PIXE
2017
Brownish bowl originating from an underwater shipwreck located near Belitung island in the Java Sea, some 600 km south-east from Singapore, has been measured with particle induced X-ray emission. This study was a pilot project for the – now a spin-off company – Recenart research team where one target was to evaluate the authenticity of the different type of art objects. PIXE measurements were done from three different material positions from a single bowl received from a customer. These locations were categorized as a bluish/greenish pigment (under glaze), thick glaze and the body clay. When the obtained data was compared to the other references from different dynasties and kiln sites, the …
RADIOMETRIC CALIBRATION OF A MULTISPECTRAL CAMERA
2006
We describe in detail a method for calibrating a multispectral imaging system based on interference filters. The calibration aims to remove systematic noises introduced by the sensor, and optic and/or filters from multispectral images. After which, we can correct the non-linearity of the sensor response. Systematic noises are measured through a rigorous protocol for acquiring offset, and thermal, and Flat-Field images. The methods for acquiring Flat-Field image, and linearizing sensor response are novel and particularly efficient in the case of a multispectral imaging system. Indeed, in such a system, the reconstruction of a spectrum for each pixel comes from the set of values taken by this…
Automated Detection of Optic Disc Location in Retinal Images
2008
This contribution presents an automated method to locate the optic disc in color fundus images. The method uses texture descriptors and a regression based method in order to determine the best circle that fits the optic disc. The best circle is chosen from a set of circles determined with an innovative method, not using the Hough transform as past approaches. An evaluation of the proposed method has been done using a database of 40 images. On this data set, our method achieved 95% success rate for the localization of the optic disc and 70% success rate for the identification of the optic disc contour (as a circle).