Search results for "PLASMA"
showing 10 items of 4043 documents
A preliminary study on the stability of benzodiazepines in blood and plasma stored at 4 degrees C.
1997
An approach to determine the stability of benzodiazepines and some of their metabolites (n = 13) by means of a routinely applied gas chromatographic method using electron capture detection was made in this preliminary study. Validation data of the method are given. Spiked blood and plasma samples were stored at 4 degrees C and analysed at selected times up to 240 days. The concentrations of all analytes had decreased to at least 60% of the original levels at the end of the observation period. A clear pattern of breakdown could not be established. The data obtained suggest that results from long-term stored samples should be interpreted cautiously. Further investigations concerning the stabi…
First experimental proof of asymmetric charge transfer in ICP-MS/MS (ICP-QQQ-MS) through isotopically enriched oxygen as cell gas
2014
The quantification of a variety of elements in the field of ICP-MS is restricted by isobaric interferences. The recent development of ICP-MS/MS (“triple quadrupole” configuration) offers a new way to solve the problem of the detection of such elements affected by interferences because the signal caused by either the analyte or the isobaric interference can be shifted to another m/z through reactions with the cell gas (oxygen, ammonia or hydrogen). This system consists of two quadrupoles (Q1 and Q2) with a collision/reaction cell in between. When using the MS/MS mode of this configuration it becomes possible to restrict the ions entering the cell to a defined m/z and therefore get a better i…
Electrochemical pH Control at Gold Nanowires
2018
In this work, interdigitated arrays of nanowire electrodes are used with one array acting as the working electrode while the other is used to generate the required protons. Finite element simulations of the pH control electrodes were performed to provide insight on the generation and subsequent diffusion of protons. This informed the inter-tine spacing of the electrodes used.. This electrochemical pH control method was then used to enable the detection of analytes of interest.
Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold
2021
Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…
Transmembrane electrochemistry of erythrocytes: Direct electrochemical test for detecting hemolysis in whole blood
2016
A rapid method for detecting hemolysis in whole blood based on a direct electrochemical assay either in venous blood and finger blood, respectively at glassy carbon and screen-printed graphite electrodes is described. The presence of hemolysis is detected from characteristic voltammetric signatures associated to Fe-heme units in healthy and hemolyzed erythrocytes. The voltammetric response of blood was also investigated using scanning electrochemical microscopy (SECM) and scanning tunneling microscopy (STM) and involved transmembrane electrochemistry of erythrocytes superimposed to molecular electrochemistry of heme-containing proteins and heme fragments in the plasma. Voltammetric testing …
Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES)
2008
A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for th…
Optimization of operating conditions of axially and radially viewed plasmas for the determination of trace element concentrations from ultrasound-ass…
2006
Abstract The method of ultrasound-assisted extraction followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element concentrations (arsenic, copper, lead, antimony, and zinc) in shooting range areas was optimized. Optimization was achieved not only on the basis of the analysis of appropriate standard reference materials but also on that of 31 synthetic mixtures of matrix and analyte elements (aluminum, antimony, arsenic, calcium, copper, lead, iron, manganese, silicon, and zinc), in five concentrations. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg II 280.270 nm/Mg I 285.213 …
Easy detection and differentiation of Anaplasma ovis and Anaplasma marginale by PCR based on MSP4 gene
2011
Prevalence of Anaplasma, Ehrlichia, Rickettsia and Coxiella in different tick species
2011
Diversity of ankA and msp4 genes of Anaplasma phagocytophilum in Slovenia.
2015
Granulocytic anaplasmosis is a tick transmitted emerging disease in Europe and worldwide. The agent, Anaplasma phagocytophilum is transmitted by ticks of the genus Ixodes and causes infections in humans and domestic animals. The analysis of different target genes showed that in nature several genetic variants of A. phagocytophilum were present. The purpose of our study was to genetically characterize A. phagocytophilum strains from eight humans, 16 dogs, 12 wild boars, one bear and 18 tick pools from Slovenia. Therefore, the ankA and msp4 genes of A. phagocytophilum were chosen. The same genetic ankA and msp4 variant of A. phagocytophilum was detected in humans, wild boar and a part of the …