Search results for "PREP"

showing 10 items of 1334 documents

Determination of90Sr in environmental samples with resonance ionization spectroscopy in collinear geometry

1994

A new, fast technique for trace analysis of the radioactive isotopes89Sr and90Sr in environmental samples has been developed. Conventional mass separation is combined with resonance ionization spectroscopy in collinear geometry, which provides high selectivity and sensitivity. In addition, a chemical separation procedure for sample preparation has been developed. The described technique was used to determine the90Sr content in ≈ 870 m3 air samples collected near Munich during and shortly after the Chernobyl reactor accident in April 1986. The content of90Sr was measured to be 1.4 mBq per m3, corresponding to 1.6 × 109 atoms of90Sr per sample. This value is in good agreement with the results…

Materials sciencePhysics and Astronomy (miscellaneous)General EngineeringGeneral Physics and AstronomyResonanceGeometryMass spectrometrySpectral lineIsotope separationlaw.inventionlawIonizationMass spectrumSample preparationSpectroscopyApplied Physics B Lasers and Optics
researchProduct

The Influence of Stimulation Techniques on the Microbiological Changes and n-Alkane Transitions in the Soil Contaminated of Petroleum-Derived Substan…

2019

Removal of petroleum products from contaminated soil is a long-term process requiring attention and constant monitoring. The aim of this study was to determine the effect of Fyre-Zyme enzyme preparation and/or calcium carbonate on microbiological changes and conversion of n-aliphatic hydrocarbons in soil contaminated of petroleum-derived substances. The material for testing was soil contaminated with petroleum substances. The total concentration of n-alkanes with a C8–C40 chain length was 420.1 mg·kg−1 DM. The pot tests were carried out by introducing stimulators. As a decomposition promoter for n-alkanes in contaminated soil, a 6% water solution of Fyre-Zyme and/or 1% sterile CaCO3 was use…

Environmental Engineeringchemistry.chemical_element010501 environmental sciencesCalciumcomplex mixtures01 natural sciencesSoilchemistry.chemical_compoundBioremediationPetroleum productEnvironmental Chemistry0105 earth and related environmental sciencesWater Science and Technologybiologybusiness.industryEcological ModelingFyre-Zyme preparationContaminationbiology.organism_classificationPollutionSoil contaminationDecompositionCalcium carbonatechemistryEnvironmental chemistrybusinessCalcium carbonateBioremediationN-aliphatic hydrocarbonsBacteriaWater, Air, & Soil Pollution
researchProduct

Thermoplastic Properties of Endodontic Gutta-percha: A Thermographic In Vitro Study

2014

Abstract Introduction Endodontic gutta-percha undergoes deformation at temperatures above 65°C. The temperature influence of heat carriers on gutta-percha cones was investigated in vitro. Methods Six single-rooted extracted teeth were embedded in resin and fixed. The root canals were prepared (ProFile; Dentsply Maillefer, Ballaiques, Switzerland) to different tapers and bisected. Thermographic images when heating the gutta-percha cones (Roeko, Langenau, Germany) with a heat carrier (ML .12; SybronEndo, Orange, CA) at 1 and 5 mm from the working length were made with an infrared thermal imaging camera (ThermaCam P640; Flir Systems, Taby, Sweden). The device temperature was preset at 200°C. T…

Hot TemperatureMaterials scienceThermoplasticSurface PropertiesHeat carrierIn Vitro TechniquesRoot Canal Filling MaterialsThermal conductivityRoot Canal ObturationMaterials TestingHumansIn vitro studyTooth RootComposite materialMean radiant temperaturePenetration depthGeneral Dentistrychemistry.chemical_classificationbiologyThermal ConductivityGutta-perchabiology.organism_classificationIncisorchemistryThermographyInfrared thermal imagingGutta-PerchaRoot Canal PreparationJournal of Endodontics
researchProduct

Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method?

2003

This critical review discusses the conditions under which inductively coupled plasma-isotope dilution mass spectrometry (ICP-IDMS) is suitable as a routine method for trace element and element-speciation analysis. It can, in general, be concluded that ICP-IDMS has high potential for routine analysis of trace elements if the accuracy of results is of predominant analytical importance. Hyphenated techniques with ICP-IDMS suffer both from lack of commercially available isotope-labeled spike compounds for species-specific isotope dilution and from the more complicated system set-up required for species-unspecific ICP-IDMS analysis. Coupling of gas or liquid chromatography with species-specific …

ChromatographyChemistryVaporizationExtraction (chemistry)Analytical chemistryTrace elementSample preparationIsotope dilutionMass spectrometryBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryDilutionAnalytical and bioanalytical chemistry
researchProduct

The ways to the trace level analysis in infrared spectroscopy

2020

The future of infrared (IR) spectroscopy as an analytical technique is assured due to its versatility and its numerous advantages; such as the possibility to obtain molecular specific information for virtually any sample in any state with no treatment or minimal sample preparation. However, spectroscopists are not satisfied with relegating IR spectroscopy just to major and minor component analysis and have been looking at analysis at the trace level too. This review is the recognition of the brilliant research performed during the past two decades and the advances achieved in this area, which have made possible the analysis of contaminants at parts per billion (ppb) levels by IR in differen…

Chemistrybusiness.industryInfraredGeneral Chemical EngineeringSample (material)Analytical techniqueGeneral EngineeringAnalytical chemistryInfrared spectroscopyAnalytical ChemistryTrace (semiology)Component analysisSample preparationProcess engineeringbusinessSpectroscopyAnal. Methods
researchProduct

Simulated root canals preparation time, comparing ProTaper Next and WaveOne Gold systems, performed by an undergraduate student

2020

Background: The aim of this study was to compare the WaveOne Gold and ProTaper Next systems regarding the time spent preparing simulated canals performed by an inexperienced student. Material and Methods: 80 simulated L-shaped canals were randomly divided into two groups (n = 40) and numbered in order of instrumentation. Canals were instrumented with WaveOne Gold (group 1) and ProTaper Next (group 2) systems. The effective instrumentation time and the number of instrumentation cycles were recorded. All procedures were performed by the same operator. Statistical analysis was obtained by the Mann-Whitney, Kruskal-Wallis test with significance of p <0.05. Results: There were no statistically s…

medicine.medical_specialtyRoot canalDental educationEndodonticsOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineDental educationmedicineUndergraduate studentStatistical analysisInstrumentation (computer programming)General Dentistry030304 developmental biologyMathematicsUndergraduateOrthodontics0303 health sciencesResearchRoot canal preparation030206 dentistry:CIENCIAS MÉDICAS [UNESCO]EndodonticsPreclinicalmedicine.anatomical_structureUNESCO::CIENCIAS MÉDICASJournal of Clinical and Experimental Dentistry
researchProduct

Analysis of thiabendazole and procymidone in fruits and vegetables by capillary electrophoresis–electrospray mass spectrometry

2002

Abstract A capillary electrophoresis–mass spectrometry method for determining procymidone and thiabendazole in apples, grapes, oranges, pears, strawberries and tomatoes is described. Separation is achieved using a buffer of formic acid–ammonium formate at pH 3.5 with 2% of methanol. Fungicide residues present in the sample are preconcentrated by both solid-phase extraction and injection of large sample volumes into the capillary by a stacking technique, to obtain lower detection limits. Ionization is performed at atmospheric pressure in an electrospray type source and detection is carried out using positive ionization and selected ion monitoring modes. The quantitation limits are 0.005 and …

Detection limitSpectrometry Mass Electrospray IonizationElectrosprayChromatographyOrganic ChemistryPesticide ResiduesElectrophoresis CapillaryGeneral MedicineMass spectrometrySensitivity and SpecificityBiochemistryFungicides IndustrialAnalytical ChemistryBridged Bicyclo Compoundschemistry.chemical_compoundCapillary electrophoresischemistryFruitThiabendazoleVegetablesSample preparationSelected ion monitoringSolid phase extractionProcymidoneJournal of Chromatography A
researchProduct

Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring

2017

A rugged and high throughput capillary column (cLC) LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL) solid phase extraction (SPE) for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g. injection of 100 non-filtrated water samples would did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 µm). In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for …

Resolution (mass spectrometry)Capillary actionAnalytical chemistry02 engineering and technologycapillary LC01 natural scienceslaw.inventionlcsh:ChemistrylawLiquid chromatography–mass spectrometrySample preparationSolid phase extractionon-line solid phase extractionFiltrationOriginal ResearchDetection limitChromatographyChemistry010401 analytical chemistryGeneral ChemistryRepeatability021001 nanoscience & nanotechnology0104 chemical sciencespharmaceutical productsChemistrylcsh:QD1-999column switchinglarge volume injection0210 nano-technologyFrontiers in Chemistry
researchProduct

Determination of type A and type B trichothecenes in paprika and chili pepper using LC-triple quadrupole-MS and GC-ECD.

2011

There is a need to develop sensitive and accurate analytical methods for determining deoxynivalenol (DON), HT-2 toxin and T-2 toxin in paprika to properly assess the relevant risk of human exposure. An optimized analytical method for determination of HT-2 toxin and T-2 toxin using capillary gas chromatography with electron capture detection and another method for determination of DON by liquid chromatography-mass spectrometry in paprika was developed. The method for determination of HT-2 toxin and T-2 toxin that gave the best recoveries involved extraction of the sample with acetonitrile-water (84:16, v/v), clean-up by solid-phase extraction on a cartridge made of different sorbent material…

Detection limitResidue (complex analysis)ChromatographyChromatography GasElutionChemistryExtraction (chemistry)Mass SpectrometryAnalytical ChemistryTriple quadrupole mass spectrometerT-2 ToxinHumansSample preparationGas chromatographySolid phase extractionCapsicumTrichothecenesChromatography LiquidTalanta
researchProduct

Potential of human serum albumin as chiral selector of basic drugs in affinity electrokinetic chromatography-partial filling technique

2006

The enantiomeric resolution of compounds using HSA by means of affinity EKC (AEKC)-partial filling technique is the result of a delicate balance between different experimental variables such as protein concentration, running pH (background electrophoretic buffer (BGE), protein, and compound solutions), and plug length. In this paper, the possibility of using HSA as chiral selector for enantioseparation of 28 basic drugs using this methodology is studied. The effect of the physicochemical parameters, the structural properties of compounds, and compound-HSA protein binding percentages over their chiral resolution with HSA is outlined. Based on the results obtained, a decision tree is proposed…

Resolution (mass spectrometry)Clinical BiochemistryPlasma protein bindingBuffersBiochemistryChromatography AffinityAnalytical ChemistryElectrokinetic phenomenaMolar volumemedicineHumansSerum AlbuminChromatography Micellar Electrokinetic CapillaryChromatographyMolecular StructureChemistryStereoisomerismHydrogen-Ion ConcentrationHuman serum albuminChiral resolutionbody regionsElectrophoresisPharmaceutical Preparationsembryonic structuresEnantiomerHydrophobic and Hydrophilic Interactionsmedicine.drugELECTROPHORESIS
researchProduct