Search results for "PREP"

showing 10 items of 1334 documents

A simple novel configuration for in-vial microporous membrane liquid–liquid extraction

2009

Abstract A novel arrangement for microporous membrane liquid–liquid extraction from the aqueous donor phase to the organic acceptor phase within a micro-vial, which is compatible with the chromatograph autosampler is presented. The device consisted of a stoppered glass micro-vial containing the organic solvent where the septum of the screw stopper was replaced by a sized piece of membrane which is hermetically assembled to the volumetric flask containing the aqueous donor solution. The placement of the membrane in alternative contact with the solutions was achieved by orbital agitation. As a preliminary study, 2-ethylhexyl 4-(dimethylamino)benzoate has been determined (limit of quantificati…

Detection limitChromatographyAqueous solutionChemistryOrganic ChemistryExtraction (chemistry)Membranes ArtificialGeneral MedicineMicroporous materialChemical FractionationBiochemistryAnalytical ChemistryMembraneLiquid–liquid extractionPhase (matter)para-AminobenzoatesSample preparation4-Aminobenzoic AcidPorosityJournal of Chromatography A
researchProduct

Automatic in-tube SPME and fast liquid chromatography: A cost-effective method for the estimation of dibuthyl and di-2-ethylhexyl phthalates in envir…

2007

A 80-cm length commercially available capillary coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane (TBR-5) was employed to carry out on-line extraction and preconcentration of dibuthyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) in the chromatographic system. The coated capillary was placed between the sample injection loop and the injection needle of an autosampler. Variables affecting the automatic in-tube solid-phase microextraction (SPME) were optimized. A Genesis C(18) (5 cm x 4.6 mm i.d., 4 microm particle size) was employed as analytical column. The achieved limits of detection by use of diode array detection were 1 and 2.5 microg L(-1), respectively. The propo…

Detection limitChromatographyCapillary actionCost-Benefit AnalysisCoefficient of variationExtraction (chemistry)PhthalateAnalytical chemistryReproducibility of ResultsSolid-phase microextractionSensitivity and SpecificityBiochemistryDibutyl PhthalateAnalytical Chemistrychemistry.chemical_compoundchemistryDiethylhexyl PhthalateEnvironmental ChemistrySample preparationParticle sizeWater Pollutants ChemicalSpectroscopyAnalytica Chimica Acta
researchProduct

Analysis of post-harvest fungicides by micellar electrokinetic chromatography.

2001

A method based on solid-phase extraction (SPE) and micellar electrokinetic chromatography (MEKC) was developed for the simultaneous determination of carbendazim, imazalil, methylthiophanate, O-phenylphenol, prochloraz, procimidone, thiabendazole and triadimefon residues in grape, lettuce, orange and tomato. Selectivity and resolution were studied changing the pH and the concentration of the buffer, the type and concentration of surfactant and the methanol content in the mobile phase. A buffer consisting of 4 mM borate with 75 mM sodium cholate (pH 9.2) gave the best results. The recoveries of the fungicides in spiked fruit and vegetable samples ranged from 30 to 105%, and the limits of dete…

Detection limitChromatographyCarbendazimOrganic ChemistryReproducibility of ResultsSodium Dodecyl SulfateGeneral MedicineBuffersSodium CholateBiochemistryMicellar electrokinetic chromatographyAnalytical ChemistryFungicides IndustrialFungicidechemistry.chemical_compoundSurface-Active AgentsTriadimefonchemistryFruitSample preparationSolid phase extractionSodium CholateChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct

Determination of PAHs in airborne particles by accelerated solvent extraction and large-volume injection-gas chromatography-mass spectrometry.

2006

Abstract A sensitive and automated method is presented for the determination of polycyclic aromatic hydrocarbons (PAHs) in airborne particulate matter. The procedure includes extraction of PM10-bound PAHs by accelerated solvent extraction (ASE) followed by gel permeation chromatography (GPC) clean-up, and large-volume programmable temperature vaporizer (PTV–LV) injection coupled to GC–MS. The limit of detection (LOD) of the whole method, based on a signal-to-noise ratio (S/N) of 3:1, ranged from 0.26 pg m−3 to 3 pg m−3 when air volumes of 760 m3 are collected. The hexane–acetone mixture (1:1, v/v) gave the best recoveries when ASE parameters were fixed at 125 °C, 1500 psi, and a total time …

Detection limitChromatographyCentral composite designChemistryExtraction (chemistry)Analytical chemistryAnalytical ChemistryGel permeation chromatographymedia_common.cataloged_instanceSample preparationGas chromatographyGas chromatography–mass spectrometryEuropean unionmedia_common
researchProduct

Sensitive determination of free benzophenone-3 in human urine samples based on an ionic liquid as extractant phase in single-drop microextraction pri…

2007

Abstract Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has bee…

Detection limitChromatographyCentral composite designOrganic ChemistryAnalytical chemistryTemperatureIonic LiquidsGeneral MedicineBiochemistryHigh-performance liquid chromatographyChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryIonic strengthLiquid–liquid extractionStandard additionIonic liquidHumansSample preparationChromatography LiquidJournal of chromatography. A
researchProduct

Quality control of Metamitron in agrochemicals using Fourier transform infrared spectroscopy in the middle and near range

2006

Abstract Two vibrational spectrometry-based methodologies were developed for Metamitron determination in pesticide formulations. Fourier transform-middle infrared (FT-MIR) procedure was based on the extraction of Metamitron by CHCl 3 and latter determination by peak area measurement between 1556 and 1533 cm −1 , corrected with a two points baseline established from 1572 to 1514 cm −1 . Fourier transform-near infrared (FT-NIR) determination was made after the extraction of Metamitron in acetonitrile and measuring the peak area between 6434 and 6394 cm −1 corrected using a two points baseline defined between 6555 and 6228 cm −1 . Repeatability, as relative standard deviation, of 5 independent…

Detection limitChromatographyChemistryAnalytical chemistryInfrared spectroscopyRepeatabilityMass spectrometryBiochemistryFourier transform spectroscopyAnalytical Chemistrysymbols.namesakeFourier transformsymbolsEnvironmental ChemistrySample preparationFourier transform infrared spectroscopySpectroscopyAnalytica Chimica Acta
researchProduct

Simultaneous determination of As, Cd, Cr and Pb in aqua regia digests of soils and sediments using electrothermal atomic absorption spectrometry and …

2002

A method was developed for the simultaneous multi-element determination of As, Cd, Cr and Pb in aqua regia digests of soils and sediments using an electrothermal atomic absorption spectrometer with a transversely heated graphite atomizer and longitudinal Zeeman-effect background correction. A fast furnace program with no pyrolysis stage or chemical modifier was used, and the total duration of the time-temperature program of the graphite furnace was 45 s. The method detection limits calculated from blank samples were 9.5 μg l−1, 0.18 μg l−1, 6.2 μg l−1 and 2.5 μg l−1 for As, Cd, Cr and Pb, respectively. Sample preparation procedures are briefly described. The accuracy of the method was confi…

Detection limitChromatographyChemistryAnalytical chemistrySedimentAtomic and Molecular Physics and OpticsAnalytical Chemistrylaw.inventionchemistry.chemical_compoundlawSoil waterAqua regiaSample preparationGraphiteAtomic absorption spectroscopyInstrumentationPyrolysisSpectroscopySpectrochimica Acta Part B: Atomic Spectroscopy
researchProduct

Determination of ruthenium in photographic emulsions - Development and comparison of different sample treatments and mass spectrometric methods

1999

Different sample treatment procedures were combined with inductively coupled plasma mass spectrometry (ICP-MS) and negative thermal ionisation mass spectrometry (NTI-MS) for the determination of ruthenium traces in photographic emulsions. Dissolution of the samples in concentrated ammonia solution was used in connection with ICP-MS by external calibration, which has the advantage of a simple sample preparation technique but introduces high amounts of the silver matrix into the mass spectrometer. On the other hand, isotope dilution mass spectrometry (IDMS) with an enriched 99Ru spike solution was applied for ICP-MS and NTI-MS measurements, respectively, in connection with a significant reduc…

Detection limitChromatographyChemistryAnalytical chemistrychemistry.chemical_elementIsotope dilutionMass spectrometryBiochemistryRuthenium/dk/atira/pure/sustainabledevelopmentgoals/clean_water_and_sanitationMatrix (chemical analysis)Sample preparationPhotographic emulsionSDG 6 - Clean Water and SanitationInductively coupled plasma mass spectrometry
researchProduct

Chiral separation of bupivacaine enantiomers by capillary electrophoresis partial-filling technique with human serum albumin as chiral selector

2004

Abstract Capillary electrophoresis (CE) is a powerful technique for enantiomer separations due to its intrinsic high separation efficiencies, speed of analysis, low reagent consumption and small sample requirements. However, some chiral selectors present strong background UV absorption providing high detection limits. The present paper deals with the application of the partial-filling technique to the separation of bupivacaine enantiomers by capillary electrophoresis using human serum albumin (HSA) as chiral selector. In this procedure the cationic surfactant cetyltrimethylammonium bromide (CTAB) was used as a dinamic capillary coating in order to reduce the electro-osmotic flow and detect …

Detection limitChromatographyChemistryCapillary actionOrganic ChemistryAnalytical chemistryElectrophoresis CapillaryStereoisomerismGeneral MedicineElectrolyteHuman serum albuminBupivacaineBiochemistryAnalytical ChemistryCapillary electrophoresisPharmaceutical PreparationsReagentmedicineAnesthetics LocalEnantiomerEnantiomeric excessmedicine.drugJournal of Chromatography A
researchProduct

On-line preconcentration strategies for analyzing pesticides in fruits and vegetables by micellar electrokinetic chromatography.

2007

Five pesticides (fludioxonil, procymidone, pyriproxyfen, dinoseb and carbendazim) were separated in reversed migration micellar electrokinetic chromatography (RM-MEKC) using 20 mmol l(-1) phosphate buffer at pH 2.3, containing 25 mmol l(-1) sodium dodecylsulfate and 10% methanol. Three on-line concentration strategies, sweeping (SW), normal stacking with reversed migration and a water plug (SRW) and stacking with reverse migration and removal of sample matrix using polarity switching (SRMM), were compared. About 10-, 30- and 50-fold increases in detection sensitivity, compared with standard hydrodynamic injection (5 s at 0.5 psi), were observed with SW, SRW and SRMM, respectively. Limits of…

Detection limitChromatographyChemistryCarbendazimOrganic ChemistryAnalytic Sample Preparation MethodsElectrophoresis CapillaryGeneral MedicineBiochemistryOnline SystemsMicellar electrokinetic chromatographyAnalytical ChemistryFungicides Industrialchemistry.chemical_compoundElectrophoresisFruitDinosebVegetablesSample preparationSolid phase extractionProcymidonePesticidesFood AnalysisChromatography Micellar Electrokinetic CapillaryJournal of chromatography. A
researchProduct