Search results for "Pacing"
showing 10 items of 68 documents
Genome-wide characterization of chromatin binding and nucleosome spacing activity of the nucleosome remodelling ATPase ISWI.
2010
The evolutionarily conserved ATP-dependent nucleosome remodelling factor ISWI can space nucleosomes affecting a variety of nuclear processes. In Drosophila, loss of ISWI leads to global transcriptional defects and to dramatic alterations in higher-order chromatin structure, especially on the male X chromosome. In order to understand if chromatin condensation and gene expression defects, observed in ISWI mutants, are directly correlated with ISWI nucleosome spacing activity, we conducted a genome-wide survey of ISWI binding and nucleosome positioning in wild-type and ISWI mutant chromatin. Our analysis revealed that ISWI binds both genic and intergenic regions. Remarkably, we found that ISWI…
Genome-Wide Association Studies of the PR Interval in African Americans.
2011
The PR interval on the electrocardiogram reflects atrial and atrioventricular nodal conduction time. The PR interval is heritable, provides important information about arrhythmia risk, and has been suggested to differ among human races. Genome-wide association (GWA) studies have identified common genetic determinants of the PR interval in individuals of European and Asian ancestry, but there is a general paucity of GWA studies in individuals of African ancestry. We performed GWA studies in African American individuals from four cohorts (n = 6,247) to identify genetic variants associated with PR interval duration. Genotyping was performed using the Affymetrix 6.0 microarray. Imputation was p…
Cardiac output in single-lead VDD pacing versus rate-matched VVIR pacing.
1995
The importance of atrioventricular synchronous pacing compared with single-chamber rate-responsive pacing is still under discussion, especially for low-intensity workload representing daily life activities. We evaluated hemodynamics in single-lead VDD pacing versus VVIR pacing in 11 patients (8 men and 3 women, aged 58.6 +/- 13.8 years) with normal left ventricular function and a previously implanted single-lead VDDR pacemaker. A low-intensity steady-state treadmill test at 1 to 2.5 mph with a gradient of 2% to 4% was performed. Cardiac output was determined using a standard carbon dioxide rebreathing technique. Initially, the VDD mode was programmed, and after 5 minutes of exercise, cardia…
Using Accelerometry for Evaluating Energy Consumption and Running Intensity Distribution Throughout a Marathon According to Sex
2020
The proportion of females participating in long-distance races has been increasing in the last years. Although it is well-known that there are differences in how females and males face a marathon, higher research may be done to fully understand the intrinsic and extrinsic factors affecting sex differences in endurance performance. In this work, we used triaxial accelerometer devices to monitor 74 males and 14 females, aged 30 to 45 years, who finished the Valencia Marathon in 2016. Moreover, marathon split times were provided by organizers. Several physiological traits and training habits were collected from each participant. Then, we evaluated several accelerometry- and pace-estimated para…
Effect of intravenous flecainide on atrial vulnerability in man.
1983
Sixteen patients were investigated by means of programmed atrial stimulation at two different driving rates: 100 and 120/min. All patients had an increased atrial vulnerability at both driving rates. After intravenous flecainide application (1 mg/kg body weight as a bolus followed by the same amount given by infusion over a period of 20 min) the increased vulnerability was abolished in 11 and 9 patients respectively. In the remaining patients the rate of induced atrial tachyarrhythmia decreased. These findings correlate with a significant prolongation of the effective refractory period of the right atrium and a significant shortening of the relative refractory period of the right atrium. It…
Prognostic significance of repetitive ventricular response in chronic coronary artery disease.
1985
A prospective study was conducted in 267 patients with angiographically defined coronary artery disease without documented ventricular tachycardia to determine the prognostic significance of repetitive ventricular response (RVR) after programmed electrical stimulation (PES). The patients were classified inducible if RVR with 3 or more echo beats (RVR greater than or equal to 3) could be induced. 89 patients without previous myocardial infarction (MI), 61 survivors of MI occurring between 6 weeks and 3 months before and 117 patients who had survived longer than 3 months after MI were studied. A standardized stimulation protocol with single (S1S2) and double (S1S2S3) extrastimuli during ventr…
Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers
2002
WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …
Selective pacing sites
2015
The right ventricular apex (RVA) has always been the most used pacing site, because it is easily accessible and provides a stable lead position with a low dislodgment rate. However, it is well-known that long-term right ventricular apical pacing may have deleterious effects on left ventricular function by inducing a iatrogenic left bundle branch block, which can have strong influences on the left ventricle hemodynamic performances. More specifically, RVA pacing causes abnormal contraction patterns and the consequent dyssynchrony may cause myocardial perfusion defects, histopathological alterations, left ventricular dilation and both systolic and diastolic left ventricular dysfunction. All t…
Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and …
2008
Udgivelsesdato: 2008-Mar AIMS: Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to convention…
Pacing ventricolare destro: una risorsa o una minaccia?
2005
Early after the beginning of the pacemaker era, endocardial right ventricular apex has been the most extensively used site for cardiac pacing because it was easily accessible and reliable in a long-term perspective. However many data have demonstrated that this kind of pacing is suboptimal from a physiologic point of view because it causes several adverse effects such as altered ventricular contraction geometry, mitral regurgitation, perfusion alterations and interference with myocardial ion channels which determine a worsening of left ventricular function. Several strategies have been proposed to solve these problems (alternative pacing sites, specific algorithms able to reduce the percent…