Search results for "Pacing"
showing 10 items of 68 documents
On the interlayer spacing collaps of the Cloisite® 30B organoclay
2011
Pacemaker therapy in premature children with high degree AV block.
1998
The smallest pacemaker pulse generator and a steroid-eluting bipolar epicardial lead were implanted in two premature children with symptomatic AV block. Stable capture threshold and high amplitude evoked response electrogram resulted in normal function of the pacemaker Autocapture algorithm, which adjusts output 0.3 V above the measured capture threshold. Autocapture had previously been used only with endocardial leads. Longer-term observation is required.
2D Isochronal Correlation Method to Detect Pacing Capture during Ventricular Fibrillation
2009
During ventricular fibrillation (VF), a portion of myocardial tissue can be captured by pacing at a rate near the fibrillation rate. Interruption of ventricular fibrillation can be favored by achieving stable myocardial capture, lowering the energy required for electrical cardioversion. Existence of myocardial capture during electrical stimulation is determined by visual inspection of electrograms (EGM) by an experienced observer. The objective of this work is the development of a semi-automatic method for the detection of myocardial capture based on the 2D correlation of isochronal maps. In 4 isolated rabbit hearts VF was induced by ventricular pacing with an increasing rate. An array of 1…
Chronic Apical and Nonapical Right Ventricular Pacing in Patients with High-Grade Atrioventricular Block: Results of the Right Pace Study
2018
Objective. The aim of the study was to compare the two approaches to chronic right ventricular pacing currently adopted in clinical practice: right ventricular apical (RVA) and non-RVA pacing. Background. Chronic RVA pacing is associated with an increased risk of atrial fibrillation, morbidity, and even mortality. Non-RVA pacing may yield more physiologic ventricular activation and provide potential long-term benefits and has recently been adopted as standard procedure at many implanting centers. Methods. The Right Pace study was a multicenter, prospective, single-blind, nonrandomized trial involving 437 patients indicated for dual-chamber pacemaker implantation with a high percentage of RV…
Cardiac pacing in premature infants and neonates: steroid eluting leads and automatic output adaptation
1999
Abstract Background . Appropriate generator and lead selection as well as techniques of implantation are most important aspects of cardiac pacing in the extremely young patient. Here we report the clinical results using a new technique with automatic output adaptation based on evoked response in combination with steroid-eluting epicardial leads in small children. Methods . One neonate and 2 premature infants underwent permanent pacemaker implantation because of congenital high-degree atrioventricular block or postoperative complete heart block, respectively. Steroid-eluting epicardial leads and a multiprogrammable pacemaker with automatic output adaptation were used. Results . Intermuscular…
Cultivation of Dill (Anethum graveolens L.) with Different Row Arrangements
2011
Dill (Anethum graveolens L.) is an annual plant from the Umbelliferae. Although in cookery also sprouts and tender leaves are used, the drug from dill is represented by the scented fruits (“seeds”), largely used for flavouring conserved foods and liqueurs, but also by the herbal and cosmetic industry. In this work, we present the results of a trial performed in Sicily, putting under comparison four different row arrangements: CR30 (continuous rows 30 cm apart), CR60 (continuous rows 60 cm apart), CR90 (continuous rows 90 cm apart) and TR (twin rows with a distance of 30 cm inside and 60 cm between twin rows). The plant population on the row (12 plants m-1) was constant and according the row…
Domestic vs. International correlations of interest rate maturities
2010
The association between long and short interest rates is traditionally envisaged from a purely domestic perspective, where it is believed an empirical regularity. Hence, the weakening of this relationship in the first half of the 2000s has represented a conundrum, calling for a reassessment of the term structure and the conduct of monetary policy. Some commentators have called for investigations into the international dimension of this puzzle. Hence, in this paper we employ recent advances in panel data econometrics to investigate the co-movement of interest rate maturities both at the domestic and international levels for a sample of industrial countries. Specifically, we use the Ng (2006)…
The psychophysiological influence of exertion and affect on sport-specific cognitive and physical performance
2022
Objectives: The purpose of the present study was to examine differences in cognitive and physical performance, affective states, perceived exertion, and physiological responses between trials with cognitive, physical, or combined cognitive and physical load. Design: Randomised cross-over trial. Methods: Highly trained competitive orienteers (n = 15 men; n = 10 women) completed three randomised trials comprised of: (1) sport-specific cognitive tests; (2) 35-minute cycling time trial; and (3) combined sport-specific cognitive tests and 35-minute cycling time trial. Measures taken during the trials recorded affective states, perceived exertion, heart rate, blood lactate, cycling watts, as well…
Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms.
2006
Aims An algorithm that alerts implantable cardioverter-defibrillator (ICD) patients, in case of abnormal lead impedance (Patient Alert™, Medtronic), may help to recognize lead dysfunction. We aimed to determine the utility of Patient Alert for ICD lead-failure detection in a prospective study. Methods and results Three hundred and sixty ICD patients were followed for 22±14 months. Patient Alert was active for pacing impedance 2000–3000 Ω, and high-voltage conductor impedance 200 Ω. Ten alert events and a total of 29 severe system complications occurred. Patient Alert detected three of 10 ICD lead failures, with a positive predictive value (PPV) of 77.8% for any severe system complication. R…
Closed loop stimulation improve ejection fraction in pediatric patients with pacemaker and ventricular dysfunction
2007
Background: The aim of this prospective study was to evaluate the effect of the closed loop stimulation (CLS) on the ejection fraction in pediatric patients, affected by complete atrioventricular block (CAVB) or CAVB and sinus node dysfunction (SND), with a previously implanted pacemaker (PM) and ventricular dysfunction. The role of electrical therapy in the treatment of pediatric patients with congenital atrioventricular (AV) blocks has been shown. Conventional right ventricular pacing seems to affect ventricular function. Up to now, the feasibility and the long-term results of biventricular pacing in pediatric patients were not entirely clear. Methods: In eight pediatric patients with a p…