Search results for "Partial discharge"
showing 10 items of 70 documents
A Two-End Traveling Wave Fault Location System for MV Cables
2019
In this paper, a new low-cost device is proposed for fault location in power distribution system. The device is part of a system that should include several units installed in couples at the two ends of medium voltage (MV) cable lines. Their low cost justifies a widespread installation of these devices, moreover other functionalities could be considered so as to enrich the potential of the system for MV cables monitoring and asset management. The system exploits a two-end traveling wave technique, low complexity, and low-cost solutions both for the analog front end as well as for the communication infrastructure. A LoRa network is indeed considered as wireless modulation technique perfectly…
Partial Discharge Detection Using a Spherical Electromagnetic Sensor
2019
The presence of a partial discharge phenomenon in an electrical apparatus is a warning signal that could determine the failure of the insulation system, terminating the service of the apparatus and/or the network. In this paper, an innovative partial discharge (PD) measurement instrument based on an antenna sensor is presented and analyzed. Being non-intrusive is one of the most relevant features of the sensor. The frequency response of the antenna sensor and the features to recognize different PD sources and automatically synchronize them with the supply voltage are described and discussed in details. The results show the performance of the instrument can make a fast and correct diagnosis …
High-Speed Machines: Typologies, Standards, and Operation under PWM Supply
2018
This paper presents an overview of the most recent state of the art in the field of high-speed electric machines fed through high-frequency converters. This type of systems is rapidly wide spreading in aeronautical and automotive applications, as well as microturbines. Each typology has its own advantages and downsides, which are analytically presented in this paper. Some types of high-speed electric machines require high-frequency voltage supply, highly stressing the dielectric materials of the winding insulation system. For this reason, in high-speed electric drives, premature failure may occur and a reduction of the total system reliability has been observed in the past years. Such issue…
Partial Discharge Measurements under DC Voltages Containing Harmonics Produced by Power Electronic Devices
2018
Partial Discharge (PD) monitoring is one of the main diagnostic instrument to evaluate the reliability of modern electrical transmission and distribution systems. The widespread use of High voltage dc (HVDC) connections increase the demand of voltage source converters (VSCs) which, as a consequence, has brought about new challenges in the field of partial discharge measurements. In fact, the output voltage waveforms generated by AC/DC modular multilevel converters (MMCs) are affected by a significant harmonic content which influences the Partial Discharges (PDs) activity. For this reason, previous research mainly investigated the PD phenomenon on the AC side of the converter. The aim of the…
The Partial Discharge Behavior of Different Materials under DC Periodic Stress
2019
The aim of the present work is to evaluate the PDs behavior by stressing a specimen with a new type of waveform named DCP. This waveform was proposed by the authors in a previous work with the aim to overcome the main issues of PDs under DC stress. In the previous work PDs test on Kapton specimen was performed. In this paper, we propose a new DCP test on a different insulating material, such as the XLPE. The obtained patterns and the acquired data have been evaluated in order to validate the DCP approach as a new method for PDs measure under constant stress. The behavior of the XLPE material has been reported and compared with the former measures obtained for Kapton material.
Partial discharge behavior under single phase half and full-bridge rectifier
2017
The aim of the present work is to simulate partial discharges (PDs) phenomena under voltage stress close to the Direct Current (DC) waveform. The employed waveforms have been realized by using a full-wave and a half-wave rectifiers. After that, in order to generate a steadier voltage supply, a capacitive filter has been inserted in the output of the half-wave rectifier. Simulations have been carried out by modifying a previous software used in the case of Alternating Current (AC). Finally, experimental tests have been carried out in order to validate simulation results.
A novel flexible approach for prediction and on line diagnostic of partial discharge
2004
Partial discharges (PD), due to unavoidable local defects produced by the industrial manufacturing process, can determine local erosion of the material that may cause the electrical breakdown of the component in which the dielectric material represents the fundamental part. Recently, improved diagnostics of electrical insulation systems by means of electric PD measurements through a stochastic processing of the acquired data have been carried out. In this way, the identification of the defects as well, as the separation of multiple defects simultaneously active, have been performed. In this paper, a novel flexible approach for the on-line characterization of the defects in a dielectric mate…
Remote voltage synchronization for wireless Partial Discharge diagnostics
2016
The main objective of this paper is the assessment of the exact phase angle displacement of each Partial Discharge, PD, pulse with respect to the voltage reference waveform. Such problem also referred to as ‘synchronization’ is relevant when the cable is not accessible and the PD measure is carried out in wireless mode. It is well known, that the angle phase shift, due to the propagation phenomenon on the transmission line, can be calculated knowing the line type and length and typical operating conditions of the transmission line. The setup comprises a customized electronic device, the “Phase check”, a server to collect remote measurements and a Look up table to provide corrections to the …
Partial Discharges Diagnostics Along Medium Voltage Cables
2018
In the last years different partial discharge (PD) measuring techniques have been developed because PD diagnostic is the most widely tool to evaluate the insulation condition of a power cable. Recently non-conventional methods and sensors have been used in order to reach improved results in PD measurements. New sensors based on wireless technology were developed in order to simplify PD measurement especially for on-line, on-site diagnosis. The purpose of this work is to perform measurements that allow to study the variation of pulses when they travel along a medium voltage cable and characterize a new smart PD source detector and locator, named Wings sensor. For these purposes, internal PD …
Influence on PD Parameters due to Voltage Conducted Disturbances
2004
In the standard specification of ac dielectric-characteristic measurements of insulating materials, test voltage is prescribed as "approximately sinusoidal" when the highest acceptable deviation of the HV waveform, from the correct sinusoidal shape, is limited to a /spl plusmn/5% tolerance range of the crest factor value. In the field of partial discharge (PD) measurements and their statistical data processing, on which forecasts of long term behavior of components and their reliability are currently carried out, the results of elaborations depend on the voltage wave shape. In this paper, the errors in PD measurements, evaluated at industrial frequencies, due to applied voltages distorted b…