Search results for "Pattern recognition"
showing 10 items of 2301 documents
Time-Frequency behaviour of the a-wave of the human electroretinogram
2007
The electroretinogram is the record of the electrical response of the retina to a light stimulus. The two main components are the a-wave and the b-wave, the former is related to the early photoreceptoral activity. Aim of this paper is to acquire useful information about the time-frequency features of the human a-wave, by means of the wavelet analysis. This represents a proper approach in dealing with nonstationary signals. We have used the Mexican Hat as mother wavelet. The analysis, carried out for four representative values of the luminance, comprehends the frequency dependence of the variance and the skeleton. The results indicate a predominance of low frequency components, their time di…
Restricted Decontamination for the Imbalanced Training Sample Problem
2003
The problem of imbalanced training data in supervised methods is currently receiving growing attention. Imbalanced data means that one class is much more represented than the others in the training sample. It has been observed that this situation, which arises in several practical domains, may produce an important deterioration of the classification accuracy, in particular with patterns belonging to the less represented classes. In the present paper, we report experimental results that point at the convenience of correctly downsizing the majority class while simultaneously increasing the size of the minority one in order to balance both classes. This is obtained by applying a modification o…
Characterization of the human visual system threshold performance by a weighting function in the Gabor domain
1997
Abstract As evidenced by many physiological and psychophysical reports, the receptive fields of the first-stage set of mechanisms of the visual process fit to two-dimensional (2D) compactly supported harmonic functions. The application of this set of band-pass filter functions to the input signal implies that the visual system carries out some kind of conjoint space/spatial frequency transform. Assuming that a conjoint transform is carried out, we present in this paper a new characterization of the visual system performance by means of a weighting function in the conjoint domain. We have called this weighting function (in the particular case of the Gabor transform) the Gabor stimuli Sensiti…
Writer identification for historical handwritten documents using a single feature extraction method
2020
International audience; With the growth of artificial intelligence techniques the problem of writer identification from historical documents has gained increased interest. It consists on knowing the identity of writers of these documents. This paper introduces our baseline system for writer identification, tested on a large dataset of latin historical manuscripts used in the ICDAR 2019 competition. The proposed system yielded the best results using Scale Invariant Feature Transform (SIFT) as a single feature extraction method, without any preprocessing stage. The system was compared against four teams who participated in the competition with different feature extraction methods: SRS-LBP, SI…
XIPE: the x-ray imaging polarimetry explorer
2016
XIPE, the X-ray Imaging Polarimetry Explorer, is a mission dedicated to X-ray Astronomy. At the time of writing XIPE is in a competitive phase A as fourth medium size mission of ESA (M4). It promises to reopen the polarimetry window in high energy Astrophysics after more than 4 decades thanks to a detector that efficiently exploits the photoelectric effect and to X-ray optics with large effective area. XIPE uniqueness is time-spectrally-spatially- resolved X-ray polarimetry as a breakthrough in high energy astrophysics and fundamental physics. Indeed the payload consists of three Gas Pixel Detectors at the focus of three X-ray optics with a total effective area larger than one XMM mirror bu…
ATHENA WFI optical blocking filters development status toward the end of the instrument phase-A
2018
Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. The Wide Field Imager (WFI) is one of the two instruments of the ATHENA astrophysics space mission approved by ESA as the second large mission in the Cosmic Vision 2015-2025 Science Programme. The WFI, based on a large array of depleted field effect transistors (DEPFET), will provide imaging in the 0.2-15 keV band over a 40'x40' field of view, simultaneously with spectrally an…
ATHENA X-IFU thermal filters development status toward the end of the instrument phase-A
2018
Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. The X-ray Integral Field Unit (X-IFU) is one of the two instruments of the Athena astrophysics space mission approved by ESA in the Cosmic Vision 2015-2025 Science Programme. The X-IFU consists of a large array of transition edge sensor micro-calorimeters that will operate at 100 mK inside a sophisticated cryostat. A set of thin filters, highly transparent to X-rays, will be m…
The LOFT mission concept: a status update
2016
The Large Observatory For x-ray Timing (LOFT) is a mission concept which was proposed to ESA as M3 and M4 candidate in the framework of the Cosmic Vision 2015-2025 program. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument and the uniquely large field of view of its wide field monitor, LOFT will be able to study the behaviour of matter in extreme conditions such as the strong gravitational field in the innermost regions close to black holes and neutron stars and the supra-nuclear densities in the interiors of neutron stars. The science payload is based on a Large Area Detector (LAD, >8m2 effective area, 2-30 keV, 240 eV spectral resolut…
Electron and photon energy calibration with the ATLAS detector using 2015-2016 LHC proton-proton collision data
2019
Artículo realizado por muchos autores. Solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración y los autores que firman como pertenecientes a la UAM
Hardware Computation of Moment Functions in a Silicon Retina Using Binary Patterns
2006
International audience; We present in this paper a method for implementing moment functions in a CMOS retina for shape recognition applications. The method is based on the use of binary patterns and it allows the computation of different moment functions such geometric and Zernike moments of any orders by an adequate choice of the binary patterns. The advantages of the method over other methods described in the literature is that it is particularly suitable for the design of a programmable retina circuit where moment functions of different orders are obtained by simply loading the correct binary patterns into the memory devices implemented on the circuit. The moment values computed by the m…