Search results for "Penn"
showing 10 items of 568 documents
Open Science now: A systematic literature review for an integrated definition
2018
Abstract Open Science is a disruptive phenomenon that is emerging around the world and especially in Europe. Open Science brings about socio-cultural and technological change, based on openness and connectivity, on how research is designed, performed, captured, and assessed. Several studies show that there is a lack of awareness about what Open Science is, mainly due to the fact that there is no formal definition of Open Science. The purpose of this paper is to build a rigorous, integrated, and up-to-date definition of the Open Science phenomenon through a systematic literature review. The resulting definition “Open Science is transparent and accessible knowledge that is shared and develope…
Breakdown of the Isobaric Multiplet Mass Equation atA=33,T=3/2
2001
Mass measurements on ${}^{33,34,42,43}\mathrm{Ar}$ were performed using the Penning trap mass spectrometer ISOLTRAP and a newly constructed linear Paul trap. This arrangement allowed us, for the first time, to extend Penning trap mass measurements to nuclides with half-lives below one second ( ${}^{33}\mathrm{Ar}$: ${T}_{1/2}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}174\mathrm{ms}$). A mass accuracy of about ${10}^{\ensuremath{-}7}$ $(\ensuremath{\delta}m\ensuremath{\approx}4\mathrm{keV})$ was achieved for all investigated nuclides. The isobaric multiplet mass equation was checked for the $A\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}33$, $T\phantom{\rule{0ex}{0ex}}=\phantom…
Precision Measurements of Atomic Masses Using Highly Charged Ions and Atomic Clusters
1992
A high precision Penning trap will be connected to the beam of highly charged ions from the electron beam ion source CRYSIS at the Manne Siegbahn Institute for Physics (MSI) in Stockholm. The first series of experiments aim at accurate mass measurements by exploiting the increase of the cyclotron frequency with the charge state of the trapped ion. Using charged states of about 50 it should be possible to achieve relative mass accuracies for mass doublets better than 10-9. For this high accuracy a Penning trap with low imperfections is needed, as well as a sophisticated beam handling and retardation system for controlled injection of the ions into the trap. In order to minimize the effect of…
Precision mass measurements using a penning trap and highly charged ions produced in an electron beam ion source
1997
A method for precision mass measurements in a Penning trap using highly charged ions produced in an electron beam ion source (CRYSIS) has been developed. The cyclotron frequencies for O8+, 7+, 6+, 5+ and Ar18+, 17+, 16+, 15+, 14+, 13+ ions have been determined by the excitation of the sum frequency v+ + v−. In addition to CRYSIS ions, H+, H2+ and He+ ions were produced by electron bombardment of the H2 rest gas or helium gas introduced through an UHV leak valve into an auxiliary ion trap (or a pre-trap). A technique for fast (seconds) interchanging of the ion species in the precision trap has been implemented to reduce the long term magnetic field drift.
Decay pathways of stored metal-cluster anions after collisional activation
1999
Size-selected gold clusters, Open image in new window (n ≤ 21), and tungsten clusters, Open image in new window , and Open image in new window (n = 4 – 8 and 12), stored in a Penning trap have been collisionally activated. Neutral monomer and dimer evaporation are observed in the case of gold. While no fragment products have been observed for tungsten clusters, there is evidence of electron emission from the anions.
Observation of multiply charged silver-cluster anions
2001
Singly charged silver-cluster anions are produced in a laser vaporization source and transferred into a Penning trap. After size selection the clusters are subjected to an electron bath in the trap, which results in the attachment of further electrons. The relative abundance of dianions or trianions as a function of the clusters' size is analyzed by time-of-flight mass spectrometry. Silver-cluster dianions are observed for sizes n≥ 24 and trianions for n > 100. In addition, a detailed study of the cluster sizes 24 ?n? 60 shows a pronounced resistance to electron attachment for singly charged anions Agn- with a closed electronic shell, in particular Ag29-, Ag33-, and Ag39-. Both the threshol…
Determination of the g-Factor of Single Hydrogen-Like Ions by Mode Coupling in a Penning Trap
2004
A method has been developed and applied for the determination of the electronic g-factor of single hydrogen-like ions stored in a Penning trap. The method is based on mode coupling of the ion trapping motions and is conceptionally advantageous as compared to previously used methods. It has been applied to hydrogen-like oxygen 16O7+ and yields a value for the gJ-factor which is in agreement with previously determined values. Experimental requirements and possibilities of the new method are discussed.
A Penning Trap for Studying Cluster Ions
1986
We propose to use a Penning trap for spectroscopy of stored cluster ions. A similar device has been built for the purpose of mass measurements of short-lived nuclei produced at the on-line isotope separator ISOLDE/CERN. A resolving power of 500,000 in a mass measurement of39K and an accuracy of 2 × 10−7 for the85Rb/39K mass ratio were obtained. An efficiency for in-flight capture as high as 70% was achieved. The method provides very high sensitivity since typically only 10 to 100 ions are stored in the trap. We intend to perform laser spectroscopy on trapped Na clusters as a first application of the trap technique.
Dawning of the N=32 shell closure seen through precision mass measurements of neutron-rich titanium isotopes
2018
A precision mass investigation of the neutron-rich titanium isotopes 51 − 55 Ti was performed at TRIUMF’s Ion Trap for Atomic and Nuclear science (TITAN). The range of the measurements covers the N = 32 shell closure, and the overall uncertainties of the 52 − 55 Ti mass values were significantly reduced. Our results conclusively establish the existence of the weak shell effect at N = 32 , narrowing down the abrupt onset of this shell closure. Our data were compared with state-of-the-art ab initio shell model calculations which, despite very successfully describing where the N = 32 shell gap is strong, overpredict its strength and extent in titanium and heavier isotones. These measurements a…
Investigation of ISIS and Brookhaven National Laboratory ion source electrodes after extended operation.
2012
Linac4 accelerator of Centre Européen de Recherches Nucléaires is under construction and a RFdriven H− ion source is being developed. The beam current requirement for Linac4 is very challenging: 80 mA must be provided. Cesiated plasma discharge ion sources such as Penning or magnetron sources are also potential candidates. Accelerator ion sources must achieve typical reliability figures of 95% and above. Investigating and understanding the underlying mechanisms involved with source failure or ageing is critical when selecting the ion source technology. Plasma discharge driven surface ion sources rely on molybdenum cathodes. Deformation of the cathode surfaces is visible after extended opera…