Search results for "Photoplethysmogram"
showing 10 items of 84 documents
Analysis of multi-spectral photoplethysmograph biosensors
2013
Multi-spectral photoplethysmograph biosensor intended for analysis of peripheral blood volume pulsations at different vascular depths has been experimentally tested. Light emitting diodes with four different wavelengths were used as the light emitters. A single photodiode with multi-channel signal output processing was used as the light detector. This study analyzed rising time difference between wavelengths at systole maximum, wavelengths relations between systole and diastole peak difference. The proposed methodology is discussed.
Clinical measurements analysis of multi-spectral photoplethysmograph biosensors
2014
The developed portable multi-spectral photoplethysmograph (MS-PPG) optical biosensor device, intended for analysis of peripheral blood volume pulsations at different vascular depths, has been clinically verified. Multi-spectral monitoring was performed by means of a four – wavelengths (454 nm, 519 nm, 632 nm and 888 nm) light emitted diodes and photodiode with multi-channel signal output processing. Two such sensors can be operated in parallel and imposed on the patient’s skin. The clinical measurements confirmed ability to detect PPG signals at four wavelengths simultaneously and to record temporal differences in the signal shapes (corresponding to different penetration depths) in normal a…
Clinical measurements with multi-spectral photoplethysmography sensors
2012
A portable multi-spectral photoplethysmography device has been used for studies of 40 subjects. Multi-spectral monitoring was performed by means of a four - wavelengths (465 nm, 530 nm, 630 nm and 870 nm) light emitted diodes (LED) and a single photodiode with multi-channel signal output processing. The proposed methodology and potential clinical applications are discussed.
Novel laser technologies for human skin in-vivo assessment
2007
Two experimental methodologies for human skin optical non-invasive in-vivo assessment have been developed and clinically tested - imaging of the laser-excited autofluorescence fading rate, and simultaneous recording of the reflectance photoplethysmography signals at several laser wavelengths with different skin penetration depths. Details of both equipments are described along with some measurement results illustrating feasibility of the novel technologies.
Challenges in automated estimation of capillary refill time in dogs
2018
Capillary refill time (CRT) is a part of the cardiorespiratory examination in dogs. Changes in CRT can reflect pathological conditions like shock or anemia. Visual CRT estimation has low repeatability; therefore, optical systems for automated estimation have recently appeared. Since existing systems are unsuitable for use in dogs, we designed a simple, small and portable device, which could be easily used at veterinary clinic. The device was preliminarily tested on several measurement sites in two dogs. Not all measurement sites were suitable for CRT measurements due to underlying tissue optical and mechanical properties. The CRT measurements were possible on the labial mucosa, above the st…
Real-time analysis of skin capillary-refill processes using blue LED
2010
A method for analysis of skin capillary-refill processes in real time by means of reflection photoplethysmography (PPG) contact probe operating in the blue (438nm ± 30 nm) and infrared (938 nm ± 20 nm) regions of spectrum is proposed. The corresponding prototype hardware and software for measurements have been developed and tested in laboratory. Realtime measurements of finger capillary refill kinetics by this technology have been taken and analyzed. Results demonstrated that both AC and DC components of the blue PPG biosignal are sensitive to capillary occlusion and refill.
<title>Optical sensing for early cardiovascular diagnostics</title>
2000
A sensor device for noninvasive detection and analysis of the pulsating blood flow waveforms by means of the reflective single-period photoplethysmorgraphy (SPPPG) technique has been designed and clinically tested. The sensor is operated jointly with any standard PC, by connecting the sensor head to the AD-card and using a separate hard disc with the signal processing software; all circuits are fed by the PC power supply. After processing, normalized shape of the mean SPPPG signal and its parameters are calculated and displayed; the measurement/processing time does not exceed 2 minutes. The clinically detected SPPPG signal shapes and corresponding parameters are presented and discussed. The…
Portable two-channel PPG cardiovascular sensor device
2003
A portable sensor device for simultaneous detection and processing of skin-remitted optical signals from any two sites of the body has been developed and tested. The photoplethysmography (PPG) principle was applied to follow the dilatation and contraction of skin blood vessels during the cardiac cycle. The newly developed two-channel approach allows to estimate the vascular blood flow resistance by analysis of time shifts between the PPG pulses detected at different body sites. Potential of the sensor device for express-assessment of human cardio-vascular condition and for body fitness tests has been demonstrated.
Multi-spectral photoplethysmography biosensor
2011
A photoplethysmography (PPG) signal can provide very useful information about a subject's hemodynamic status in a hospital or home environment. A newly developed portable multi-spectral photoplethysmography device has been used for studies of 11 healthy subjects. The developed optical fiber biosensor comprises one multi-wavelength laser diode (405nm, 660nm and 780nm) and a single photodiode with multi-channel signal output processing and built in Li-ion accumulator; special software was created for visualization and measuring of the MS-PPG signals. ARM7TDMI-S LPC2148, NXP (founded by Philips) 32 bit processor with clock frequency of 60 MHz performs measurement and analysis of the signal.
Remote photoplethysmography for skin perfusion monitoring using narrowband illumination
2019
The purpose of this study was to determine potential of remote photoplethysmography for skin perfusion monitoring, using 540 nm narrowband and 530 nm broadband illuminations. The alterations of cutaneous circulation were produced by topical skin heating protocol. The setup comprises of 530 nm LED light source and two identical cameras operated simultaneously: one equipped with narrowband optical filter (CWL=540nm), and another without filter. Results demonstrate the typical heating test response curve- comprising first peak, nadir and plato phase, which were significantly different in narrowband and broadband illumination. It was concluded that selection of optimal light source parameters i…