A validity and reliability study of Conditional Entropy Measures of Pulse Rate Variability

2019

In this work, we present the feasibility to use a simpler methodological approach for the assessment of the short-term complexity of Heart Rate Variability (HRV). Specifically, we propose to exploit Pulse Rate Variability (PRV) recorded through photoplethysmography in place of HRV measured from the ECG, and to compute complexity via a linear Gaussian approximation in place of the standard model-free methods (e.g., nearest neighbor entropy estimates) usually applied to HRV. Linear PRV-based and model-free HRV-based complexity measures were compared via statistical tests, correlation analysis and Bland-Altman plots, demonstrating an overall good agreement. These results support the applicabil…

020205 medical informaticsComputer scienceEntropy0206 medical engineeringValidity02 engineering and technologySettore ING-INF/01 - ElettronicaElectrocardiographyPulse Rate Variability (PRV)Heart RatePhotoplethysmogram0202 electrical engineering electronic engineering information engineeringHumansEntropy (information theory)Heart rate variabilityEntropy (energy dispersal)Time seriesPhotoplethysmographyEntropy (arrow of time)Statistical hypothesis testingConditional entropyEntropy (statistical thermodynamics)Reproducibility of ResultsHeart Rate Variability (HRV)020601 biomedical engineeringSettore ING-INF/06 - Bioingegneria Elettronica E InformaticacomplexityAlgorithmEntropy (order and disorder)2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
researchProduct

Adaptive scheduling of acceleration and gyroscope for motion artifact cancelation in photoplethysmography

2022

Background and objective: Recently, various algorithms have been introduced using wrist-worn photo-plethysmography (PPG) to provide high accuracy of instantaneous heart rate (HR) estimation, including during high-intensity exercise. Most studies focus on using acceleration and/or gyroscope signals for the motion artifact (MA) reference, which attenuates or cancels out noise from the MA-corrupted PPG signals. We aim to open and pave the path to find an appropriate MA reference selection for MA cancelation in PPG.Methods: We investigated how the acceleration and gyroscope reference signals correlate with the MAs of the distorted PPG signals and derived both mathematically and experimentally a…

Adaptive motion artifact reference selectionInstantaneous heart rate (HR)Gyroscope signalAccelerationSignal Processing Computer-AssistedHealth InformaticsSettore ING-INF/01 - ElettronicaComputer Science ApplicationsAcceleration signalMotionHeart RateSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaReflectance-type photoplethysmography (PPG)PhotoplethysmographyArtifactsAlgorithmsSoftwareComputer Methods and Programs in Biomedicine
researchProduct

Optical noninvasive monitoring of skin blood pulsations

2005

Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrh…

AdultMaleAdolescentHeartbeatMaterials Science (miscellaneous)Pulsatile flowArterial Occlusive DiseasesBlood volumeSensitivity and SpecificityIndustrial and Manufacturing EngineeringOpticsData acquisitionArterial occlusionsHeart RatePhotoplethysmogrammedicineAnimalsHumansDiagnosis Computer-AssistedBusiness and International ManagementPhotoplethysmographySkinFrequency filteringbusiness.industryReproducibility of ResultsEquipment DesignEquipment Failure Analysismedicine.anatomical_structurePulsatile FlowVascular resistanceFemalesense organsbusinessAlgorithmsBlood Flow VelocityBiomedical engineeringApplied Optics
researchProduct

Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.

2014

Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…

AdultMalemedicine.medical_specialtyBiomedical EngineeringNormal DistributionHemodynamicsBiomaterialsInternal medicinePhotoplethysmogrammedicineHumansPhotoplethysmographyReactive hyperemiaHemodynamicsBlood flowArteriesmedicine.diseaseArterial occlusionAtomic and Molecular Physics and OpticsHealthy VolunteersElectronic Optical and Magnetic MaterialsFemoral Arterymedicine.anatomical_structureBlood pressureAnesthesiaCardiologyVascular resistanceArterial stiffnessFemaleVascular ResistanceJournal of biomedical optics
researchProduct

Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness

2013

Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…

AdultMalemedicine.medical_specialtyMaterials scienceOptical PhenomenaCoefficient of variationBiomedical EngineeringBlood PressureDerivativePulse Wave AnalysisSignalBiomaterialsYoung AdultVascular StiffnessPhotoplethysmogramPressuremedicineHumansPulse wavePhotoplethysmographyBlood VolumePulse (signal processing)Optical DevicesRepeatabilityAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsSurgeryTransducerFemaleBiomedical engineeringJournal of Biomedical Optics
researchProduct

Information domain analysis of respiratory sinus arrhythmia mechanisms.

2019

Ventilation related heart rate oscillations – respiratory sinus arrhythmia (RSA) – originate in human from several mechanisms. Two most important of them – the central mechanism (direct communication between respiratory and cardiomotor centers), and the peripheral mechanism (ventilation-associated blood pressure changes transferred to heart rate via baroreflex) have been described in previous studies. The major aim of this study was to compare the importance of these mechanisms in the generation of RSA non-invasively during various states by quantifying the strength of the directed interactions between heart rate, systolic blood pressure and respiratory volume signals. Seventy-eight healthy…

AdultMalemedicine.medical_specialtySupine positionAdolescentPhysiologyBlood Pressure030204 cardiovascular system & hematologyBaroreflex03 medical and health sciencesOrthostatic vital signsElectrocardiographyYoung Adult0302 clinical medicineHeart RateInternal medicineHeart ratemedicineHumansInformation measurePhotoplethysmographybusiness.industryHead-up tiltCardio-respiratory couplingCardiorespiratory fitnessGeneral MedicineBaroreflexRespiratory Sinus ArrhythmiaBlood pressureCardiologyBreathingFemalebusiness030217 neurology & neurosurgeryRespiratory minute volumePhysiological research
researchProduct

Feasibility of cuff-free measurement of systolic and diastolic arterial blood pressure

2011

We validated a prototype cuff-free device for noninvasive estimation of blood pressure (BP). The system assumed a linear relation between BP values and the inverse of arterial blood pulse transit time, measured as time interval between the R wave on the electrocardiograph and the onset of the peripheral pulse wave on a finger plethysmogram. Thirty-three healthy subjects were analyzed at rest and during increasing stress exercise. To estimate subject-specific linear model parameters, the system was calibrated ad personam with reference to BP measures obtained by a cuff sphygmomanometer. High correlation values (R2= 0.89 and 0.78 for systolic and diastolic BP, respectively) and differences co…

AdultMalemedicine.medical_specialtySystoleDiastolePulse transit timeSphygmomanometerSensitivity and SpecificityQRS complexDiastoleInternal medicineValidationmedicineHumansDiagnosis Computer-AssistedSystolePhotoplethysmographyAccuracyAgedbusiness.industryReproducibility of ResultsBlood Pressure DeterminationEquipment DesignMiddle AgedSphygmomanometersConfidence intervalSurgeryBlood pressure monitoringEquipment Failure AnalysisBlood pressurePulsatile FlowCuffSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaElectrocardiography AmbulatoryCardiologyNoninvasive measurementFeasibility StudiesArterial bloodFemalebusinessCardiology and Cardiovascular Medicine
researchProduct

Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths

2016

The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…

AdultPathologymedicine.medical_specialtyAdolescentBiomedical EngineeringLinimentHyperemiaCutaneous microcirculation02 engineering and technologyAdministration Cutaneous01 natural sciencesMicrocirculation010309 opticsBiomaterialsYoung AdultPhotoplethysmogram0103 physical sciencesImage Processing Computer-AssistedHumansMedicinePhotoplethysmographySkinbusiness.industryMicrocirculationEquipment DesignLaser Doppler velocimetryHand021001 nanoscience & nanotechnologyArterial occlusionAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials0210 nano-technologybusinessPerfusionPreclinical imagingAnesthesia LocalBiomedical engineeringJournal of Biomedical Optics
researchProduct

Bilateral photoplethysmography studies of the leg arterial stenosis.

2005

A newly developed portable multi-channel photoplethysmography (PPG) device has been used for comparative studies of 20 healthy control subjects and 45 patients with diagnosed arterial stenosis in a leg. The peripheral blood pulsations were detected simultaneously at four body sites-the same fingers and toes of both arms and legs. The PPG pulses recorded at the periphery of the stenotic leg, if compared with those of the healthy leg, were much weaker, with delayed arrival as a consequence of increased pulse wave transit time (PWTT) due to higher vascular resistance. The specific PWTT delays for the occluded legs were in the range of 20-80 ms, while in the case of healthy subjects the leg PPG…

Adultmedicine.medical_specialtyPhysiologyBiomedical EngineeringBiophysicsArterial Occlusive DiseasesBlood PressurePhysiology (medical)PhotoplethysmogramInternal medicineHealthy controlmedicineOscillometryHumansPhotoplethysmographyAgedAged 80 and overPeripheral Vascular DiseasesLegArterial stenosisbusiness.industryHealthy subjectsMiddle Agedmedicine.diseaseSurgerybody regionsStenosisBlood pressuremedicine.anatomical_structureVascular resistanceCardiologybusinessPhysiological measurement
researchProduct

Pulse rate variability measurement with camera-based photoplethysmography

2021

Electrocardiogram (ECG) has been used by doctors and biomedical researchers to measure cardiac parameters such as Heart Rate (HR) and Heart Rate Variability (HRV). HR is a medical index for health monitoring and the HRV is a sign to reflect the activities of Autonomic Nervous System (ANS) and can be used for emotion recognition applications. Recently, remote photoplethysmography (rPPG) has evolved as a non-contact technique for measuring vital cardiac signs. Compared with ECG, this technique is non-invasive, low-cost, comfortable and possibly utilized in long-term monitoring. It has great potential in remote health assessment and emotion detection. However, the rPPG is a video-based method,…

Cardiac varaibilioty[INFO.INFO-TI] Computer Science [cs]/Image Processing [eess.IV]Photoplethysmographie (PPG)Video content analysis[INFO.INFO-TI]Computer Science [cs]/Image Processing [eess.IV]Variabilité cardiaquePhotoplethysmography (PPG)Analyse de contenu vidéo