Search results for "Pipette"

showing 4 items of 4 documents

Intracellular fluoride influences TASK mediated currents in human T cells.

2019

The expression of Kv1.3 and KCa channels in human T cells is essential for maintaining cell activation, proliferation and migration during an inflammatory response. Recently, an additional residual current, sensitive to anandamide and A293, compounds specifically inhibiting currents mediated by TASK channels, was observed after complete pharmacological blockade of Kv1.3 and KCa channels. This finding was not consistently observed throughout different studies and, an in-depth review of the different recording conditions used for the electrophysiological analysis of K+ currents in T cells revealed fluoride as major anionic component of the pipette intracellular solutions in the initial studie…

0301 basic medicinePatch-Clamp TechniquesTime FactorsPotassium CompoundsT-LymphocytesImmunologyMagnesium ChlorideMembrane Potentials03 medical and health scienceschemistry.chemical_compoundFluorides0302 clinical medicinePotassium Channels Tandem Pore DomainPotassium Channel BlockersImmunology and AllergyHumansCells CulturedKv1.3 Potassium ChannelActivator (genetics)ChemistryPipetteAnandamideElectrophysiology030104 developmental biologyMembraneBiophysicsCell activationFluorideIntracellular030215 immunologyJournal of immunological methods
researchProduct

Single mechano-gated channels activated by mechanical deformation of acutely isolated cardiac fibroblasts from rats

2010

Aim Mechanosensitive conductances were reported in cardiac fibroblasts, but the properties of single channels mediating their mechanosensitivity remain uncharacterized. The aim of this work was to investigate single mechano-gated channels (MGCs) activated by mechanical deformations of cardiac fibroblasts. Methods Currents through single MGCs and mechanosensitive whole-cell currents were recorded from isolated rat atrial fibroblasts using the cell-attached and whole-cell patch-clamp configurations respectively. Defined mechanical stress was applied via the patch pipette used for the whole-cell recordings. Results Under resting conditions occasional short openings of two types of single MGCs …

MaleCytochalasin DPatch-Clamp TechniquesPhysiologyCell SeparationIon Channelschemistry.chemical_compoundPressureAnimalsMyocyteMyocytes CardiacHeart AtriaPatch clampReversal potentialCell ShapeNucleic Acid Synthesis InhibitorsCytochalasin DPipetteAnatomyFibroblastsElectric StimulationRatsElectrophysiologySolutionsCoupling (electronics)ElectrophysiologychemistryBiophysicsMechanosensitive channelsColchicineIon Channel GatingActa Physiologica
researchProduct

User-oriented evaluation of mechanical single-channel axial pipettes.

2013

Hand tools should be designed so that they are comfortable to use, fit the hand and are user-oriented. Six different manual, single-channel axial pipettes were evaluated for such objective outcomes as muscular activity, wrist postures and efficiency, as well as for subjective outcomes concerning self-assessed features of pipette usability and musculoskeletal strain. Ten experienced laboratory employees volunteered for the study. The results showed that light and short pipettes with better tool comfort resulted in reduced muscular activity and perceived musculoskeletal strain when they were compared with a long and heavy pipette. There were no differences in the efficiency between the differ…

Wrist JointEngineeringCumulative Trauma DisordersSurface PropertiesPhysical Therapy Sports Therapy and RehabilitationHuman Factors and ErgonomicsEfficiencyPersonal SatisfactionHand toolFingersIsometric ContractionTask Performance and AnalysisHumansUser orientedSafety Risk Reliability and QualityEngineering (miscellaneous)Man-Machine SystemsSimulationArthrometry Articularbusiness.industryClinical Laboratory TechniquesElectromyographyWork (physics)PipetteHand InjuriesUsabilityta3142Equipment DesignHandCumulative trauma disorderOccupational DiseasesForearmLaboratory PersonnelCross-Sectional StudiesAttitudeNew product developmentFemaleErgonomicsbusinessCommunication channelApplied ergonomics
researchProduct

Comparison of Two Solid-Phase Extraction (SPE) Methods for the Identification and Quantification of Porcine Retinal Protein Markers by LC-MS/MS

2018

Proper sample preparation protocols represent a critical step for liquid chromatography-mass spectrometry (LC-MS)-based proteomic study designs and influence the speed, performance and automation of high-throughput data acquisition. The main objective of this study was to compare two commercial solid-phase extraction (SPE)-based sample preparation protocols (comprising SOLA&micro

0301 basic medicineSwineGeneral Mathematicssample clean-upProteomicsMass spectrometry01 natural sciencesCatalysisRetinaArticlelcsh:ChemistryInorganic Chemistry03 medical and health scienceschemistry.chemical_compoundglaucoma animal modelZIPTIP® C18 pipette tipsTandem Mass SpectrometryLiquid chromatography–mass spectrometryTrifluoroacetic acidAnimalsSample preparationSolid phase extractionPhysical and Theoretical ChemistryEye Proteinslcsh:QH301-705.5Molecular BiologySpectroscopymass spectrometryZIPTIP<sup>®</sup> C18 pipette tipsReproducibilityChromatographyChemistryApplied Mathematics010401 analytical chemistryOrganic ChemistrySolid Phase ExtractionExtraction (chemistry)PipettebiomarkersGlaucomaGeneral Medicine0104 chemical sciencesComputer Science Applications030104 developmental biologylcsh:Biology (General)lcsh:QD1-999SOLAμTM HRP SPE spin platesPeptidesChromatography LiquidInternational Journal of Molecular Sciences
researchProduct