Search results for "Polar"
showing 10 items of 3817 documents
Vegetation index retrieval by coupling optical and SAR images
2012
Monitoring spatial and temporal variability of Vegetation Indices (VIs) is important to manage land and water resources, with significant impact on the sustainability of modern agriculture Although algorithms based on optical data give accurate products, cloud cover dramatically reduces the temporal resolution of these outputs. The launch of new Synthetic Aperture Radar (SAR) constellations such as COSMO-Skymed opened new opportunities to develop agro-hydrological applications. Indeed, these satellites may represent a suitable source of data for operational applications due to their high spatial and temporal resolutions (10 m in StripMap PingPong acquisition mode, best revisit time with 4 s…
Investigating the Relationship between X-Band SAR Data from COSMO-SkyMed Satellite and NDVI for LAI Detection
2013
Monitoring spatial and temporal variability of vegetation is important to manage land and water resources, with significant impact on the sustainability of modern agriculture. Cloud cover noticeably reduces the temporal resolution of retrievals based on optical data. COSMO-SkyMed (the new Italian Synthetic Aperture RADAR-SAR) opened new opportunities to develop agro-hydrological applications. Indeed, it represents a valuable source of data for operational use, due to the high spatial and temporal resolutions. Although X-band is not the most suitable to model agricultural and hydrological processes, an assessment of vegetation development can be achieved combing optical vegetation indices (V…
Synthetic aperture microscopy using off-axis illumination and polarization coding
2007
A new method to improve the resolution of optical imaging systems beyond the classical Rayleigh resolution limit is presented. The technique relies on synthetic aperture generation in three stages. The first one (encoding stage) uses an illumination procedure that combines both on-axis and off-axis illumination beams with different polarization states onto the object. After the imaging system, a second stage (decoding stage) allows the recovering of the encoded spatial-frequency object information by means of an interferometric configuration based on the polarization coding carried out in the previous stage. Finally, a third stage (digital post-processing stage) is used to generate a synthe…
Palermo e Santa Lucia siracusana
2014
Nella Sicilia paleocristiana, il culto della martire dioclezianea Loukìa conosce una notevole fortuna nei primi secoli del Cristianesimo, tanto da varcare i confini dell’Isola e da estendersi nel Mediterraneo occidentale e orientale; molto si deve, in questo senso, all’opera pastorale dei pontefici, sin dalla fine del secolo IV. Anche Palermo partecipò della promozione del culto della martire, come attesta la fondazione gregoriana di un cenobio latino dedicato ai santi Agata e Massimo in Lucuscanum; è ben nota, infatti, la connessione tra le due sante Lucia e Agata, testimoniata non solo dai ben noti luoghi dei testi agiografici, ma anche dalle innovazioni nella liturgia introdotte dal papa…
Pion Form Factor at BESIII
2017
Abstract At BESIII, we measured the cross section of e + e − → π + π − in the energy range between 600 and 900 MeV/c2 with a 2.93 fb−1 data set taken at the center-of-mass energy 3.773 GeV. The initial state radiation technique is used, and the total systematic uncertainty is estimated to be 0.9%. The squared form factor | F π | 2 is extracted, and comparisons are made with results from both KLOE and BaBar. The two-pion contribution to the hadronic vacuum polarization contribution to ( g − 2 ) μ is calculated to be a μ π π , LO ( 600 − 900 MeV / c 2 ) = ( 368.2 ± 2.5 s t a t . ± 3.3 s y s t . ) ⋅ 10 − 10 .
Improved tau polarisation measurement
1996
Using 22 pb−1 of data collected at LEP in 1992 on the peak of the Z resonance, the ALEPH collaboration has measured the polarisation of the tau leptons decaying into $$ev\bar v, \mu v\bar v$$ ,πν, ρν and a1 ν from their individual decay product distributions. The measurement of the tau polarisation as a function of the production polar angle yields the two parametersN τ andN e, where, in terms of the axial and vector couplingsg Al andg Vl,N l=2g Vl gAl/(g Vl 2 +g 2 ). This analysis follows to a large extent the methods devised for the 1990 and 1991 data but with improvements which bring a better understanding of the systematic uncertainties. Combining the 1992 measurements with our previous…
Optical pulsations from a transitional millisecond pulsar
2017
Weakly magnetic, millisecond spinning neutron stars attain their very fast rotation through a 1E8-1E9 yr long phase during which they undergo disk-accretion of matter from a low mass companion star. They can be detected as accretion-powered millisecond X-ray pulsars if towards the end of this phase their magnetic field is still strong enough to channel the accreting matter towards the magnetic poles. When mass transfer is much reduced or ceases altogether, pulsed emission generated by particle acceleration in the magnetosphere and powered by the rotation of the neutron star is observed, preferentially in the radio and gamma-ray bands. A few transitional millisecond pulsars that swing betwee…
Thermal potential of ion-exchange membranes and its application to thermoelectric power generation
2016
The low efficiency and high price of thermoelectric semiconductors has generated interest in unconventional forms of thermoelectric materials. In this article, ionic thermoelectricity has been studied with commercial ion-exchange membranes for different aqueous 1:1 electrolytes. The theory of thermal membrane potential has been derived taking into account the ionic heats of transport, the non-isothermal Donnan potentials, the temperature polarization, and the thermally-induced concentration polarization of the electrolyte. Also the generated thermoelectric power has been experimentally studied. The experiments show good agreement with the theory, and suggest ways for systematic improvement …
Non-invasive localization of atrial ectopic beats by using simulated body surface P-wave integral maps
2017
Non-invasive localization of continuous atrial ectopic beats remains a cornerstone for the treatment of atrial arrhythmias. The lack of accurate tools to guide electrophysiologists leads to an increase in the recurrence rate of ablation procedures. Existing approaches are based on the analysis of the P-waves main characteristics and the forward body surface potential maps (BSPMs) or on the inverse estimation of the electric activity of the heart from those BSPMs. These methods have not provided an efficient and systematic tool to localize ectopic triggers. In this work, we propose the use of machine learning techniques to spatially cluster and classify ectopic atrial foci into clearly diffe…
Longitudinal spin-relaxation in nitrogen-vacancy centers in electron irradiated diamond
2015
We present systematic measurements of longitudinal relaxation rates ($1/T_1$) of spin polarization in the ground state of the nitrogen-vacancy (NV$^-$) color center in synthetic diamond as a function of NV$^-$ concentration and magnetic field $B$. NV$^-$ centers were created by irradiating a Type 1b single-crystal diamond along the [100] axis with 200 keV electrons from a transmission electron microscope with varying doses to achieve spots of different NV$^-$ center concentrations. Values of ($1/T_1$) were measured for each spot as a function of $B$.