Search results for "Polar"
showing 10 items of 3817 documents
Determination of limiting current density and current efficiency in electrodialysis units
2018
Abstract A crucial parameter for the design and operation of electrodialysis (ED) units is the limiting current density (LCD). This is often identified with the diffusion-limited current density, which corresponds to the complete solute depletion in the layer adjacent to the membrane. Current-voltage curves obtained from measurements with electrodes in contact with the solution (i.e. without membranes) are consistent with this interpretation and exhibit a horizontal plateau identifying LCD. However, real ED systems show more complex behaviours, with a reduced-slope tract instead of a plateau and a third region in which the current increases more markedly (overlimiting current). The phenomen…
Membrane distillation heat transfer enhancement by CFD analysis of internal module geometry
2011
Module geometry optimisation can be a crucial matter in all separation processes using selective or hydrophobic membranes, e.g. reverse osmosis (RO) and membrane distillation (MD). In fact the choice of suitable channel shape and size can dramatically affect the performance of the process. With reference to the membrane distillation process, temperature polarization phenomena and pres¬sure drops along the channels largely affect the process efficiency (i.e. the efficient use of temperature driving force for the passage of vapour through the membrane) as well as pressure distribution, module mechanical resistance and pumping costs. Several works have been presented so far in literature on th…
The Wide Field Imager of the International X-ray Observatory
2010
The International X-ray Observatory (IXO) will be a joint X-ray observatory mission by ESA, NASA and JAXA. It will have a large effective area (3 m 2 at 1.25 keV) grazing incidence mirror system with good angular resolution (5 arcsec at 0.1–10 keV) and will feature a comprehensive suite of scientific instruments: an X-ray Microcalorimeter Spectrometer, a High Time Resolution Spectrometer, an X-ray Polarimeter, an X-ray Grating Spectrometer, a Hard X-ray Imager and a Wide-Field Imager. The Wide Field Imager (WFI) has a field-of-view of 18 ft � 18 ft. It will be sensitive between 0.1 and 15 keV, offer the full angular resolution of the mirrors and good energy resolution. The WFI will be imple…
XIPE: the x-ray imaging polarimetry explorer
2016
XIPE, the X-ray Imaging Polarimetry Explorer, is a mission dedicated to X-ray Astronomy. At the time of writing XIPE is in a competitive phase A as fourth medium size mission of ESA (M4). It promises to reopen the polarimetry window in high energy Astrophysics after more than 4 decades thanks to a detector that efficiently exploits the photoelectric effect and to X-ray optics with large effective area. XIPE uniqueness is time-spectrally-spatially- resolved X-ray polarimetry as a breakthrough in high energy astrophysics and fundamental physics. Indeed the payload consists of three Gas Pixel Detectors at the focus of three X-ray optics with a total effective area larger than one XMM mirror bu…
X-ray Absorption under Operating Conditions for Solid-Oxide Fuel Cells Electrocatalysts: The Case of LSCF/YSZ
2019
We describe a novel electrochemical cell for X-ray absorption spectroscopy (XAS) experiments during electrical polarization suitable for high-temperature materials such as those used in solid oxide fuel cells. A half-cell LSCF/YSZ was then investigated under cathodic and anodic conditions (850 °
The polarization dependence of x‐ray photoelectron yield of a Au photocathode
1994
We report a measurement of the total photoelectron yield of gold as a function of the incident x‐ray polarization. Polarized x rays with energies of 2.5, 2.7, and 4.0 keV were used to excite a gold photocathode at a glancing incidence angle between 5° and 50°. Contrary to a previous report, we found no measurable polarization dependence for all three x‐ray energies. We conclude that the modulation factor, i.e., the fractional change of the total yield when the polarization state is varied, is less than 4%.
Time-dependent current-voltage characteristics of Al/p-CdTe/Pt x-ray detectors
2012
Current-voltage (I-V) characteristics of Schottky Al/p-CdTe/Pt detectors were investigated in dark and at different temperatures. CdTe detectors with Al rectifying contacts, very appealing for high resolution x-ray and gamma ray spectroscopy, suffer from bias-induced polarization phenomena which cause current increasing with the time and severe worsening of the spectroscopic performance. In this work, we studied the time-dependence of the I-V characteristics of the detectors, both in reverse and forward bias, taking into account the polarization effects. The I-V measurements, performed at different time intervals between the application of the bias voltage and the measurement of the current…
Electrophysiological and morphological properties of Cajal–Retzius cells with different ontogenetic origins
2010
International audience; The different origins of Cajal-Retzius cells (CRc) as well as their diverse molecular profile suggest that this cell type may represent different neuronal subpopulations. In order to investigate whether CRc from different origins show distinct functional or morphological characteristics we used transgenic Dbx1(cre);ROSA26(YFP) mice in which two subpopulations of CRc, originating from the septum and ventral pallium (VP) at the pallial-subpallial border (PSB), were permanently labeled by yellow fluorescent protein (YFP) expression. Electrophysiological properties of YFP(+) and YFP(-) CRc were investigated by whole-cell patch-clamp recordings, while a thorough somatoden…
Polar accumulation of the metabolic sensory histidine kinases DcuS and CitA in Escherichia coli
2008
Signal transduction in prokaryotes is frequently accomplished by two-component regulatory systems in which a histidine protein kinase is the sensory component. Many of these sensory kinases control metabolic processes that do not show an obvious requirement for inhomogeneous distribution within bacterial cells. Here, the sensory kinases DcuS and CitA, two histidine kinases of Escherichia coli, were investigated. Both are membrane-integral and involved in the regulation of carboxylate metabolism. The two-component sensors were fused with yellow fluorescent protein (YFP) and live images of immobilized cells were obtained by confocal laser fluorescence microscopy. The fluorescence of the fusio…
All polarization-maintaining passively modelocked ytterbium-doped fiber lasers, behavior under two different cavity configurations
2020
Fil: Cuadrado-Laborde, Christian. Universidad de Valencia. Departamento de Física Aplicada; España Fil: Cuadrado-Laborde, Christian. Consejo Nacional de Investigaciones Científicas. Instituto de Física Rosario; Argentina Fil: Cuadrado-Laborde, Christian. Pontificia Universidad Católica Argentina. Facultad de Química e Ingeniería del Rosario; Argentina Fil: Carrascosa, Antonio. Universidad de Valencia. Departamento de Física Aplicada; España Fil: Diez, Antonio. Universidad de Valencia. Departamento de Física Aplicada; España Fil: Cruz, J. L. Universidad de Valencia. Departamento de Física Aplicada; España Fil: Andrés, M. V. Universidad de Valencia. Departamento de Física Aplicada; España Abs…