Search results for "Power engineering"
showing 10 items of 126 documents
Robust synchronization and fault detection of uncertain master-slave systems with mixed time-varying delays and nonlinear perturbations
2011
Publiahed version of an article in the journal: International Journal of Control, Automation and Systems. Also available from the publisher on SpringerLink: http://dx.doi.org/10.1007/s12555-011-0408-8 In this paper, the problem of robust synchronization and fault detection for a class of master-slave systems subjected to some nonlinear perturbations and mixed neutral and discrete time-varying delays is investigated based on an H ∞ performance condition. By introducing a descriptor technique, using Lyapunov-Krasovskii functional and a suitable change of variables, new required sufficient conditions are established in terms of delay-dependent linear matrix inequalities to synthesize the resid…
Data-Driven Adaptive Observer for Fault Diagnosis
2012
Published version of an article from the journal: Mathematical Problems in Engineering. Also available from the publisher:http://dx.doi.org/10.1155/2012/832836 This paper presents an approach for data-driven design of fault diagnosis system. The proposed fault diagnosis scheme consists of an adaptive residual generator and a bank of isolation observers, whose parameters are directly identified from the process data without identification of complete process model. To deal with normal variations in the process, the parameters of residual generator are online updated by standard adaptive technique to achieve reliable fault detection performance. After a fault is successfully detected, the iso…
Fault-Reconstruction-Based Cascaded Sliding Mode Observers for Descriptor Linear Systems
2012
Published version of an article from the journal: Mathematical Problems in Engineering. Also available from the publisher:http://dx.doi.org/10.1155/2012/623426 This paper develops a cascaded sliding mode observer method to reconstruct actuator faults for a class of descriptor linear systems. Based on a new canonical form, a novel design method is presented to discuss the existence conditions of the sliding mode observer. Furthermore, the proposed method is extended to general descriptor linear systems with actuator faults. Finally, the effectiveness of the proposed technique is illustrated by a simulation example.
Potential for Usage of Thermoelectric Generators on Ships
2010
Published version of an article from the journal: Journal of Electronic Materials. he original publication is available at Springerlink. http://dx.doi.org/10.1007/s11664-010-1189-1 The useful waste heat potential for a bulk carrier has been evaluated as a preliminary step towards developing a thermoelectric generator (TEG) waste heat recovery system for ships. A medium-sized bulk carrier produces 6.2 MW of waste heat, and the most promising usable sources for the TEG are shown herein to be the exhausts from the main engine and the sludge oil incinerator.
Mixed l-/l1 fault detection observer design for positive switched systems with time-varying delay via delta operator approach
2014
Published version of an article in the journal: International Journal of Control, Automation and Systems. Also available from the publisher at: http://dx.doi.org/10.1007/s12555-013-0466-1 This paper investigates the problem of fault detection observer design for positive switched systems with time-varying delay via delta operator approach. A new fault sensitivity measure, called l-index, is proposed. The l- fault detection observer design and multi-objective l -/l1 fault detection observer design problems are addressed. Based on the average dwell time approach and the piecewise copositive type Lyapunov-Krasovskii functional method in delta domain, sufficient conditions for the existence of …
Run-Time Reconfiguration for Emulating Transient Faults in VLSI Systems
2006
Advances in circuitry integration increase the probability of occurrence of transient faults in VLSI systems. A confident use of these systems requires the study of their behaviour in the presence of such faults. This study can be conducted using model-based fault injection techniques. In that context, field-programmable gate arrays (FPGAs) offer a great promise by enabling those techniques to execute models faster. This paper focuses on how run-time reconfiguration techniques can be used for emulating the occurrence of transient faults in VLSI models. Although the use of FPGAs for that purpose has been restricted so far to the well-known bit-flip fault model, recent studies in fault repres…
Cluster matching in time resolved imaging for VLSI analysis
2014
International audience; If scaling has the benefit of enabling manufacturers to design tomorrow's integrated circuits, from the failure analyst point of view it also has the drawback of making devices more complex. The test sequence for modern VLSI can be quite long, with thousands of vector. Dynamic photon emission databases can contain millions of photons representing thousands of state changes in the region of interest. Finding a candidate location where to perform physical analysis is quite challenging, especially if the fault occurs on a single vector. In this paper, we suggest a new methodology to find single vector fault in dynamic photon emission database. The process is applied at …
Current characterisation for ultra low power wireless body area networks
2010
The emerging area of body area networks (BAN) imposes challenging requirements on hardware and software to achieve the desired lifetimes for certain devices such as long term medical implants. In this paper, we propose a novel approach to the measurement and characterisation of the energy consumption of BAN devices. The approach uses a low cost energy auditing circuit and addresses the problem of accurately measuring low-level current consumption. This new technique will allow precise and analytical measurements of systems and components in terms of energy. This will help circuit designers minimise power consumption in BAN devices. Software engineers might use this approach to validate and …
On the de-energization of over-head low-voltage lines under high-impedance fault conditions
2018
Downed distribution conductors in overhead distribution systems, may not be a concern for equipment, but greatly challenge the safety of persons, as well as the integrity of properties. Upstream overcurrent protective devices may not be able to detect the magnitudes of fault currents resulting from these high-impedance faults. Even though protective devices capable to detect such faults have been available on the market, not all the utilities have equipped their stations with these products, likely due to the costs. In this paper, the authors formalize the problem, and propose a possible cost-effective solution for the low-voltage over-head lines with neutral wire. Such solution includes a …
Role of Foreseeability in Imposition of Civil Liability
2021
The purpose of this article is to offer an insight into the role of foreseeability in imposition of civil liability. The article contains analysis of the principle of foreseeability from various points of view, for example, by analysing it from the perspective of the general (fault-based) model of liability as well of the strict liability. Likewise, the article analysis the role of foreseeability during determination of preconditions to civil liability, for example, by introducing it into the concepts of “fault” and “causation”. The aspects referred to in this article are predominantly analysed from the theoretical perspective. The article references various legal sources from different co…