Search results for "Precision"

showing 10 items of 448 documents

3D reconstruction of hot metallic surfaces for industrial part characterization

2009

During industrial forging of big hot metallic shells, it is necessary to regularly measure the dimensions of the parts, especially the inner and outer diameters and the thickness of the walls, in order to decide when to stop the forging process. The inner and outer diameters of the shells range from 4 to 6 meters and to measure them a large ruler is placed horizontally at the end of the shell. Two blacksmiths standing on each side of the ruler at about ten meters from it visually reads the graduations on the ruler in order to determine the inner and outer diameters from which the thickness of the wall is determined. This operation is carried out several times during a forging process and it…

Accuracy and precisionTime of flightMaterials scienceOpticsDimensional Measurement Accuracy[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]business.industrySystem of measurementDimensional metrologyShell (structure)Point cloudbusinessForging
researchProduct

Objective Amplitude of Accommodation Computed from Optical Quality Metrics Applied to Wavefront Outcomes

2009

Purpose: We studied the accuracy and precision of 32 objective wavefront methods for finding the amplitude of accommodation obtained in 180 eyes. Methods: Ocular accommodation was stimulated with 0.5 D steps in target vergence spanning the full range of accommodation for each subject. Subjective monocular amplitude of accommodation was measured using two clinical methods, using negative lenses and with a custom Badal optometer. Results: Both subjective methods gave similar results. Results obtained from the Badal optometer where used to test the accuracy of the objective methods. All objective methods showed lower amplitude of accommodation that the subjective ones by an amount that varied …

Accuracy and precisionamplitude of accommodationgenetic structuresComputer scienceAcousticssubjective methods050105 experimental psychology03 medical and health sciencesimage quality metricsobjective methods0302 clinical medicinelcsh:Ophthalmologymedicineamplitud de acomodaciónlcsh:QC350-4670501 psychology and cognitive sciencesmétodos subjetivosSimulationWavefrontmétricas de calidad de imagenmétodos objetivos05 social sciencespresbiciaPresbyopiamedicine.diseaseOptical qualityAmplitude of accommodationlcsh:RE1-994030221 ophthalmology & optometrypresbyopiaOriginal Articlelcsh:Optics. LightOptometryJournal of Optometry
researchProduct

230Th/U-dating of a late Holocene low uranium speleothem from Cuba

2010

We present 22 U-series ages for a stalagmite from north-western Cuba based on multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS) and thermal ionisation mass spectrometry (TIMS). Our results reveal that the stalagmite continuously grew within the last ~1400a. Low uranium content of the sample and thus, extremely low 230Th concentrations limit the precision and accuracy of 230Th/U-dating by TIMS. Samples measured by MC-ICPMS show a high variability of 232Th content along the growth axis with some sections significantly affected by initial 230Th from a detrital phase. An a-priori bulk earth ratio for (238U/232Th) cannot be used to accurately account for this initial 230Th.…

Accuracy and precisiongeographygeography.geographical_feature_categoryMineralogyThermal ionizationSpeleothemchemistry.chemical_elementStalagmiteUraniumMass spectrometrychemistryInductively coupled plasma mass spectrometryGeologyHoloceneIOP Conference Series: Earth and Environmental Science
researchProduct

Non-destructive automatic determination of aspect ratio and cross-sectional properties of fibres

2015

A novel method for computerised estimation of the aspect ratio distribution and various cross-sectional geometrical properties of fibres in short-fibre reinforced composites is proposed. The method, based on X-ray micro-computed tomography, is non-destructive and does not require user intervention. Based on results on specially fabricated model material, the accuracy and precision of the method seems adequate. The method is applied in analysing a manufacturing process of wood fibre reinforced thermoplastic composite. The results indicate a significant decrease of the aspect ratio of fibres during the processing steps. Finally, the feasibility of the method is assessed by estimating paramete…

Accuracy and precisionx-ray tomographykuidutMaterials scienceAspect ratiota114business.industrynon-destructive testingMicromechanical modelfibresMechanics of MaterialsNon destructiveNondestructive testingUltimate tensile strengthrikkomaton aineenkoetusCeramics and CompositesTomographyComposite materialstatistical propertiesbusinessWood fibreX-ray tomography
researchProduct

Automatic detection and classification of retinal vascular landmarks

2014

The main contribution of this paper is introducing a method to distinguish between different landmarks of the retina: bifurcations and crossings. The methodology may help in differentiating between arteries and veins and is useful in identifying diseases and other special pathologies, too. The method does not need any special skills, thus it can be assimilated to an automatic way for pinpointing landmarks; moreover it gives good responses for very small vessels. A skeletonized representation, taken out from the segmented binary image (obtained through a preprocessing step), is used to identify pixels with three or more neighbors. Then, the junction points are classified into bifurcations or…

Acoustics and UltrasonicsComputer scienceMaterials Science (miscellaneous)General MathematicsPreprocessorRadiology Nuclear Medicine and imagingComputer visionretinal vessel landmark points retinal vessel structure classificationRepresentation (mathematics)Instrumentationlcsh:R5-920PixelSettore INF/01 - Informaticabusiness.industryBinary imagelcsh:Mathematicslcsh:QA1-939retinal vessel structure classificationSignal ProcessingComputer Vision and Pattern RecognitionArtificial intelligencebusinessPrecision and recallretinal vessel landmark pointslcsh:Medicine (General)Biotechnology
researchProduct

Pooled analysis of prospective European studies assessing the impact of using the 21-gene Recurrence Score assay on clinical decision making in women…

2016

PURPOSE: The 21-gene Recurrence Score assay (Oncotype DX) provides prognostic/predictive information in oestrogen receptor positive (ER+) early breast cancer, but access/reimbursement has been limited in most European countries in the absence of prospective outcome data. Recently, two large prospective studies and a real-life 5-year outcome study have been reported. We performed a pooled analysis of prospective European impact studies to generate robust data on impact of use in different clinical subgroups. METHODS: The analysis included four studies (French, German, Spanish, and British) in ER+ human epidermal growth factor receptor 2-negative breast cancer patients (n = 527). Node-positiv…

Adult0301 basic medicineOncologyCancer Researchmedicine.medical_specialtyReceptor ErbB-2medicine.medical_treatmentClinical Decision-MakingBreast NeoplasmsMama -- Càncer -- TractamentRisk AssessmentSeverity of Illness Index03 medical and health sciencesBreast cancer0302 clinical medicineBreast cancerInternal medicineQuimioteràpiaHumansMedicineProspective StudiesOestrogen receptorPrecision MedicineStage (cooking)Prospective cohort studyReimbursementAgedAged 80 and overGynecologyChemotherapyIndividualised medicinemedicine.diagnostic_testbusiness.industryGene Expression ProfilingMiddle Agedmedicine.diseaseTumor BurdenAdjuvant chemotherapyEurope030104 developmental biologyReceptors EstrogenOncology030220 oncology & carcinogenesisHormonal therapyFemaleNeoplasm Recurrence LocalbusinessOncotype DXClinical decision makingEuropean Journal of Cancer
researchProduct

Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM)

1996

The objective of this article was to analyze the accuracy and precision with which the quantitative distribution of articular cartilage can be determined in the knee joint using MRI. A three-dimensional (3D) technique that accounts for the out-of-plane deviation of the interface normal in strongly curved joint surfaces (3D MR-CCM) has been developed for cartilage thickness measurements. Eight cadaveric knee-joint specimens and six volunteers were imaged using a fat-suppressed gradient-echo sequence at a resolution of 2 x 0.31 x 0.31 mm3. Cartilage volumes and topographical thickness maps were obtained and compared with those derived from anatomical sections by image analysis. The deviation …

AdultCartilage ArticularMalemusculoskeletal diseasesAccuracy and precisionMaterials scienceKnee JointCoefficient of variationKnee JointmedicineHumansRadiology Nuclear Medicine and imagingJoint (geology)AgedAged 80 and overObserver Variationmedicine.diagnostic_testCartilageReproducibility of ResultsMagnetic resonance imagingAnatomyMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structureFemalePatellaCadaveric spasmBiomedical engineeringMagnetic Resonance in Medicine
researchProduct

The Randomized Shortened Dental Arch Study

2012

The scientific evidence concerning prosthodontic care for the shortened dental arch (SDA) is sparse. This randomized multicenter study aimed to compare two common treatment options: removable partial dental prostheses (RPDPs) for molar replacement vs. no replacement (SDA). One of the hypotheses was that the follow-up treatment differs between patients with RPDPs and patients with SDAs during the 5-year follow-up period. Two hundred and fifteen patients with complete molar loss in one jaw were included in the study. Molars were either replaced by RPDPs or not replaced according to the SDA concept. A mean number of 4.2 (RPDP) and 2.8 (SDA) treatments for biological or technical reasons occur…

AdultChange over timeMolarmedicine.medical_treatmentDentistryDental Abutmentslaw.inventionTooth LossDental ArchRandomized controlled triallawmedicineDenture Precision AttachmentHumansBicuspidProspective StudiesDenture DesignGeneral DentistryObservation timebusiness.industryJaw Edentulous PartiallyTreatment optionsDenture RetentionMolarDental archTreatment Outcomemedicine.anatomical_structureMulticenter studyDenture Partial RemovableProsthodonticsbusinessFollow-Up StudiesJournal of Dental Research
researchProduct

Developmental and Early Life Origins of Cardiometabolic Risk Factors

2021

The intent of this review is to critically consider the data that support the concept of programming and its implications. Birth weight and growth trajectories during childhood are associated with cardiometabolic disease in adult life. Both extremes, low and high birth weight coupled with postnatal growth increase the early presence of cardiometabolic risk factors and vascular imprinting, crucial elements of this framework. Data coming from epigenetics, proteomics, metabolomics, and microbiota added relevant information and contribute to better understanding of mechanisms as well as development of biomarkers helping to move forward to take actions. Research has reached a stage in which suff…

AdultEpigenomicsMaleProteomicsGerontologyAgingAdolescentBirth weightGestational Age030204 cardiovascular system & hematologyCardiovascular SystemEpigenesis Genetic03 medical and health sciences0302 clinical medicineMetabolic DiseasesAdverse Childhood ExperiencesPregnancyRisk FactorsInternal MedicineBirth WeightHumansMetabolomics030212 general & internal medicinePrecision MedicinePostnatal growthChildImprinting (organizational theory)High birth weightCardiometabolic riskMicrobiotaInfant NewbornInfantInfant Low Birth WeightMiddle AgedEarly lifeAdult lifeCardiovascular DiseasesChild PreschoolPrenatal Exposure Delayed EffectsFemalePsychologyRelevant informationInfant PrematureForecastingHypertension
researchProduct

Determination of somatic oncogenic mutations linked to target-based therapies using MassARRAY technology

2016

Somatic mutation analysis represents a useful tool in selecting personalized therapy. The aim of our study was to determine the presence of common genetic events affecting actionable oncogenes using a MassARRAY technology in patients with advanced solid tumors who were potential candidates for target-based therapies. The analysis of 238 mutations across 19 oncogenes was performed in 197 formalin-fixed paraffin-embedded samples of different tumors using the OncoCarta Panel v1.0 (Sequenom Hamburg, Germany). Of the 197 specimens, 97 (49.2%) presented at least one mutation. Forty-nine different oncogenic mutations in 16 genes were detected. Mutations in KRAS and PIK3CA were detected in 40/97 (4…

AdultMale0301 basic medicineOncologymedicine.medical_specialtyColorectal cancersomatic oncogene mutationsDNA Mutational Analysismedicine.disease_cause03 medical and health sciences0302 clinical medicineGermline mutationNeoplasmsInternal medicineHumansMedicineoncocartaPrecision MedicineGeneAgedAged 80 and overGeneticsMutationbusiness.industryHigh-Throughput Nucleotide Sequencingpersonalized medicineMiddle AgedPrecision medicinemedicine.diseaseClinical trial030104 developmental biologyOncologySpectrometry Mass Matrix-Assisted Laser Desorption-Ionization030220 oncology & carcinogenesisFemalePersonalized medicineKRASbusinessResearch PaperOncotarget
researchProduct