Search results for "Pressure"
showing 10 items of 4493 documents
Modelling and Simulation of the Longterm Behaviour of Arterial Pressure Regulation with the Aid of a Block — Diagrammed Interactive Simulation System
1983
The possibility of developing a managable closed nonlinear mathematical model of the renovascular system for longterm blood pressure regulation is outlined. The developed model is a parametric one. Its structure contains explicitely the biological parameters.
Organisational responses to regulatory pressure: A case study of a Norwegian Research University’s strategic compliance to GDPR
2020
Master's thesis in Innovative governance and public management (ME523) This thesis study seeks to test Oliver’s (1991) theory for prediction of Strategic Responses to Institutional Processes, against the case of initial responses taken by a Norwegian research university when faced with General Data Protection Regulation (GDPR) of European Union (EU).This thesis explores how different parts of the same organisation respond to and manage institutional pressure. It uses a case study of a Norwegian research university’s response to the European Union’s General Data Protection Regulation (GDPR). An exploratory case study design frame was used to address the research question, and qualitative dat…
A novel technique to follow fast PaO2 variations during experimental CPR
2003
An ultrafast responding fluorescent-quenching PO2 probe allows time-resolved, in vivo measurement of PO2. This study describes several validation experiments of this new device in vitro, and reports its first use during cardiopulmonary resuscitation in an animal model of cardiac arrest.The influence of CO2, temperature and motion artefacts on the signal response of the PO2 probe was analysed in vitro by systematic variation of these values. Thereafter, with approval of the Review Board for the care and use of animals, CPR was performed in four pigs. The PaO2 course was recorded continuously at time resolution of80 ms in the abdominal aorta using an uncoated fluorescence-quenching probe (Fox…
Performance of a high repetition pulse rate laser system for in-gas-jet laser ionization studies with the Leuven laser ion source @ LISOL
2012
The Leuven Isotope Separator On-Line (LISOL) facility at the Cyclotron Research Center (CRC) Louvain-la-Neuve; The laser ionization efficiency of the Leuven gas cell-based laser ion source was investigated under on- and off-line conditions using two distinctly different laser setups: a low-repetition rate dye laser system and a high-repetition rate Ti:sapphire laser system. A systematic study of the ion signal dependence on repetition rate and laser pulse energy was performed in off-line tests using stable cobalt and copper isotopes. These studies also included in-gas-jet laser spectroscopy measurements on the hyperfine structure of 63Cu. A final run under on-line conditions in which the ra…
The FURIOS laser ion source at IGISOL-4
2013
Abstract The FURIOS laser ion source at the Accelerator Laboratory of the University of Jyvaskyla has been moved to a new location as a part of the IGISOL-4 facility. The laser ion source project had a high priority which allowed the transport of laser light to be optimized during the design phase. The laser resonators have been upgraded with a dual etalon configuration leading to greatly reduced laser linewidth. The transport efficiency of the dual-chamber gas cell has been determined using an alpha recoil source, with efficiencies ranging from a few percent in the beam interaction chamber to nearly 20% in the ionization chamber. In addition, we present recent results from the re-commissio…
A compact apparatus for mass selective resonance ionization spectroscopy in a buffer gas cell
1997
Abstract An ultra-sensitive laser spectroscopic method for the investigation of transuranium nuclides has been developed based on resonance ionization in an argon buffer gas cell. This method has been combined with ion-guide extraction and mass selective direct detection of the resonantly ionized atoms. Using argon as a buffer gas, recoils of fusion reactions can be thermalized even at low pressure. The differential pumping system consists of only one roots pump and two turbo molecular pumps. The set-up has been tested with 243 Am evaporated from a filament located inside the optical gas cell. Resonance ionization is performed using a two-step excitation with an excimer-dye-laser combinatio…
Deep ROSAT-HRI observations of the NGC 1399/NGC 1404 region: morphology and structure of the X-ray halo
2001
We present the analysis of a deep (167 ks) ROSAT HRI observation of the cD galaxy NGC 1399 in the Fornax cluster. Using both HRI and, at larger radii, archival PSPC data, we find that the radial behavior of the X-ray surface brightness profile is not consistent with a simple Beta model and suggests instead three distinct components. We use a multi-component bidimensional model to study in detail these three components that we identify respectively with the cooling flow region, the galactic and the cluster halo. From these data we derive a binding mass distribution in agreement with that suggested by optical dynamical indicators, with an inner core dominated by luminous matter and an extende…
Development of a sequential data correction method for isotope ratio analysis by resonance ionization mass spectrometry
2015
A sequential data correction method using several experimental parameters of pulsed resonance ionization mass spectrometry was developed to reduce mass discrimination effects for isotope ratio analysis as well as fluctuations in the ion count rate. This correction method was applied to isotope ratio determination of stable titanium isotopes using a two-step, single color ionization scheme. A significant improvement of the precision of the measured isotopic ratio of stable titanium isotopes was demonstrated after correction with a parameter set consisting of laser power, atmospheric pressure, and laser frequency.
Selective laser ionization of radioactive Ni-isotopes
1997
Abstract A chemically selective laser ion source based on resonance ionization of atoms in a hot cavity has been applied in the study of Ni-isotopes at the CERN-ISOLDE on-line isotope separator. Laser ionization enhanced the yields of long-lived Ni-isotopes almost four orders of magnitude when compared to the yields obtained with the surface ionization mode of the source. As a result, high yields of long-lived Ni-isotopes were obtained. Separation efficiencies of 0.3 and 0.8% were obtained for Ni produced in uranium-carbide, produced from uranium-di-pthalocyanine, and Ta-foil targets, respectively. Ni was found to be released very slowly from the present target and ion source combination.
Ultra Trace Determination Scheme for26Al by High-Resolution Resonance Ionization Mass Spectrometry using a Pulsed Ti:Sapphire Laser
2008
We propose an ultra trace analysis approach for 26Al by high-resolution Resonance Ionization Mass Spectrometry (RIMS) using a pulsed narrow band-width Ti:Sapphire laser. For ensuring efficient ionization and high isotopic selectivity in RIMS of Al, we developed an injection seeded pulsed Ti:Sapphire laser with high repetition rate operation at up to 10 kHz. The laser produced an output power of 2 W and a spectral band-width of ~20 MHz with a repetition rate of 7 kHz. A first demonstration of its performance was done by detecting stable 27Al using RIMS.