Search results for "Prostheses"

showing 10 items of 88 documents

A New Model of Skull Base Reconstruction following Expanded Endonasal or Transoral Approaches – Long-Term Results in Primates

2007

<i>Objective:</i> The direct endonasal or transoral transclival approaches to the skull base permit effective minimally invasive surgery along the clivus region. Developing consistently effective techniques to prevent cerebrospinal fluid (CSF) leaks and their consequences (infections and healing processes with long and complicated recoveries) remains a major challenge. In this study, we tested over a long period a method of bone reconstruction newly developed by us, which makes use of a specially designed elastic silicone plug that can be employed for bone replacement after minimally invasive skull base surgery without risk of postoperative CSF leaks. After acute testing of plug…

Malemedicine.medical_specialtySiliconesPostoperative ComplicationsClivusmedicineAnimalsMinimally Invasive Surgical ProceduresBase (exponentiation)Cerebrospinal FluidSkull BaseCerebrospinal Fluid Leakagebusiness.industryForeign-Body ReactionSilicone plugEndoscopyProstheses and ImplantsLong term resultsPlastic Surgery ProceduresAnti-Bacterial AgentsSurgerySkullmedicine.anatomical_structureModels AnimalSkull base surgeryInvasive surgeryPapio hamadryasSurgerybusinessEuropean Surgical Research
researchProduct

Treatment of Severe Post-Prostatectomy Stress Urinary Incontinence Using Advance Sling

2010

Severe stress urinary incontinence (SUI) is usually treated by the implant of artificial sphincter positioned around bulbar urethra. AdVance sling is a functional, non-obstructive, anti-incontinence device that showed good results especially for mild and moderate SUI. We present our experience with AdVance sling in 7 patients with severe SUI unfit for artificial sphincter. Our results, after a follow-up of more than 6 months, showed a continence rate of 28% and an improvement rate of 43%, while 2 patients did not show any benefit. The success of AdVance sling depends on the integrity of urethral sphincter and can be applied also in selected cases for the treatment of severe post-prostatect…

Malemedicine.medical_specialtyUrinary Incontinence Stressmedicine.medical_treatmentUrologyUrinary incontinenceAdenocarcinomaDiabetes ComplicationsProsthesis ImplantationPostoperative ComplicationsHumansMedicinePost prostatectomyAgedRetrospective StudiesProstatectomybusiness.industryProstatectomyUrethral sphincterProstatic NeoplasmsRetrospective cohort studyProstheses and ImplantsGeneral MedicineMiddle AgedAdvance slingCombined Modality TherapyTreatment OutcomeChemotherapy AdjuvantImprovement rateHypertensionRadiotherapy AdjuvantImplantmedicine.symptombusinessUrologia Journal
researchProduct

Transrectal ultrasound guided implantation of the ProACT adjustable continence therapy system in patients with post-radical prostatectomy stress urin…

2006

Purpose: We evaluate the feasibility and potential advantages of ProACT system implantation using transrectal ultrasound rather than fluoroscopy for guidance. Materials and Methods: The transrectal ultrasound guided procedure was done between June and October 2005 in 7 patients with a mean age of 68.4 years (range 53 to 76) with mild to severe stress urinary incontinence after laparoscopic transperitoneal radical prostatectomy. Results: The ProACT system was successfully implanted in all cases without perioperative complications. Time needed to complete the overall procedure was 15 to 30 minutes. All transrectal ultrasound studies performed during the mean followup of 4.2 months (range 2 to…

Malemedicine.medical_specialtyUrologymedicine.medical_treatmentUrinary Incontinence StressUrinary incontinencePilot ProjectsArtificial urinary sphincterurinary sphincter artificialmedicineFluoroscopyHumansAgedUltrasonographyProstatectomyprostatemedicine.diagnostic_testbusiness.industryProstatectomyUrethral sphincterUltrasoundRectumPerioperativeProstheses and ImplantsMiddle AgedSurgeryTransrectal ultrasonographyFeasibility Studiesmedicine.symptombusiness
researchProduct

Enhanced angiogenesis in the 3D dynamic responsive implant for inguinal hernia repair ProFlor

2021

Biologic response to hernia prostheses represents a continuous source of debate. Conventional hernia meshes, in their typical static, passive configuration have been used for decades to reinforce the herniated abdominal wall. These flat implants, mainly fixated with sutures or tacks, induce poor quality fibrotic ingrowth that shrinks the mesh. In groin hernia repair, flat meshes are applied in the delicate inguinal surrounding where uncontrolled development of a scar plate can impair movement and may incorporate the sensitive nerves crossing this area. Complications deriving from mesh fixation and nerve entrapment are frequent and unpleasant for patients. To remedy these problems, a multila…

Malemedicine.medical_specialtymedicine.medical_treatment0206 medical engineeringBiomedical EngineeringNeovascularization PhysiologicMedicine (miscellaneous)Connective tissueHernia InguinalBioengineering02 engineering and technologytissue regeneration030204 cardiovascular system & hematologyPolypropylenesProsthesis DesignProsthesis ImplantationBiomaterialsAbdominal wallarteries03 medical and health sciencesangiogenesis0302 clinical medicineregenerative scaffoldsBiopsyHumansMedicineHerniaHerniorrhaphymedicine.diagnostic_testGroinbusiness.industryGeneral MedicineveinsHernia repairmedicine.disease020601 biomedical engineeringSurgeryInguinal herniamedicine.anatomical_structureinguinal herniaFemaleImplantbusinessprostheses
researchProduct

Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.

2005

To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…

Malemedicine.medical_specialtymedicine.medical_treatmentEye diseaseLens Capsule CrystallineCapsular tension ringMethylmethacrylateProsthesis ImplantationPostoperative ComplicationsLens Implantation IntraocularOphthalmologyMedicineHumansPolymethyl MethacrylateProspective StudiesIntraoperative ComplicationsCapsulorhexisShrinkageAgedPhacoemulsificationbusiness.industryAxial lengthProstheses and ImplantsCataract surgerymedicine.diseaseSensory SystemsOphthalmologyCapsular bagMethacrylatesSurgeryFemalebusinessJournal of cataract and refractive surgery
researchProduct

Response of human endothelial cells to oxidative stress on Ti6Al4V alloy.

2007

Titanium and its alloys are amongst the most frequently used materials in bone and dental implantology. The good biocompatibility of titanium(-alloys) is attributed to the formation of a titanium oxide layer on the implant surface. However, implant failures do occur and this appears to be due to titanium corrosion. Thus, cells participating in the wound healing processes around an implanted material, among them endothelial cells, might be subjected to reactive oxygen species (ROS) formed by electrochemical processes during titanium corrosion. Therefore, we studied the response of endothelial cells grown on Ti6Al4V alloy to H(2)O(2) and compared this with the response of endothelial cells gr…

Materials scienceBiophysicsCell Culture Techniqueschemistry.chemical_elementBioengineeringInflammationmedicine.disease_causeAntioxidantsBiomaterialsSuperoxide dismutasechemistry.chemical_compoundCoated Materials BiocompatibleMaterials TestingmedicineAlloysHumansCells Culturedchemistry.chemical_classificationInflammationTitaniumReactive oxygen speciesbiologySuperoxide DismutaseMetallurgytechnology industry and agricultureEndothelial CellsGlutathioneHydrogen PeroxideProstheses and Implantsequipment and suppliesGlutathioneOxidative StresschemistryMechanics of MaterialsCell cultureCeramics and Compositesbiology.proteinBiophysicsmedicine.symptomWound healingReactive Oxygen SpeciesOxidative stressTitaniumBiomaterials
researchProduct

Implantable Sensors Based on Gold Nanoparticles for Continuous Long-Term Concentration Monitoring in the Body.

2021

Implantable sensors continuously transmit information on vital values or biomarker concentrations in bodily fluids, enabling physicians to survey disease progression and monitor therapeutic success. However, currently available technologies still face difficulties with long-term operation and transferability to different analytes. We show the potential of a generalizable platform based on gold nanoparticles embedded in a hydrogel for long-term implanted biosensing. Using optical imaging and an intelligent sensor/reference-design, we assess the tissue concentration of kanamycin in anesthetized rats by interrogating our implanted sensor noninvasively through the skin. Combining a tissue-integ…

Materials scienceMechanical EngineeringAptamerDisease progressionTransferabilityMetal NanoparticlesBioengineeringNanotechnologyHydrogels02 engineering and technologyGeneral ChemistryBiosensing TechniquesProstheses and Implants021001 nanoscience & nanotechnologyCondensed Matter PhysicsRatsOptical imagingIntelligent sensorColloidal goldStill faceAnimalsGeneral Materials ScienceGold0210 nano-technologyBiosensorNano letters
researchProduct

Cell and tissue response to nanotextured Ti6Al4V and Zr implants using high-speed femtosecond laser-induced periodic surface structures

2019

In this paper, the effect of femtosecond laser nanotexturing of surfaces of Ti6Al4V and Zr implants on their biological compatibility is presented and discussed. Highly regular and homogeneous nanostructures with sub-micrometer period were imprinted on implant surfaces. Surfaces were morphologically and chemically investigated by SEM and XPS. HDFa cell lines were used for toxicity and cell viability tests, and subcutaneous implantation was applied to characterize tissue response. HDFa proliferation and in vivo experiments evidenced the strong influence of the surface topography compared to the effect of the surface elemental composition (metal or alloy). The effect of protein adsorption fro…

Materials scienceNanostructureSurface PropertiesBiomedical EngineeringPharmaceutical ScienceMedicine (miscellaneous)chemistry.chemical_elementBioengineering02 engineering and technologyOsseointegrationCell proliferation; Femtosecond laser; Fluorescence; HR-LIPSS; Nanotexturing; Cell Differentiation; Humans; Lasers; Nanostructures; Osseointegration; Osteoblasts; Osteogenesis; Surface Properties; Titanium; Zirconium; Prostheses and ImplantsFluorescencelaw.invention03 medical and health sciencesX-ray photoelectron spectroscopylawOsseointegrationOsteogenesisAlloysHumansGeneral Materials ScienceCell proliferation030304 developmental biologyTitanium0303 health sciencesOsteoblastsLasersTitanium alloyCell DifferentiationProstheses and Implants021001 nanoscience & nanotechnologyLaserNanotexturingNanostructuresFemtosecond laserchemistryFemtosecondBiophysicsMolecular MedicineHR-LIPSSZirconiumNanotexturingCell proliferationFluorescenceHR-LIPSSFemtosecond laser0210 nano-technologyTitaniumProtein adsorption
researchProduct

High-density polyethylene facial implants show surface oxidation in SEM and EDX examination: a pilot study.

2009

Previous histopathological studies on explanted Medpor high-density polyethylene (HDPE) facial implants indicated signs of material destruction and claimed to observe phagocytized HDPE particles within the tissue samples beside the usual type IV reaction with severe fibrosis. We examined new and explanted Medpor material with scanning electron microscopy (SEM) and energy-dispersive X-ray analysis (EDX). The implant surface of three patient-derived specimens showed significantly higher oxygenation in EDX analysis and morphological changes in SEM compared to the new unused material directly after opening of the package and after 1 year of exposure to air. Our preliminary findings indicate a p…

Materials scienceScanning electron microscopeSurface PropertiesBiomedical EngineeringPilot ProjectsSurgical implantsSevere fibrosisBiochemistryChemistry Techniques AnalyticalBiomaterialschemistry.chemical_compoundUsual typeSurface oxidationComposite materialMolecular BiologyX-RaysGeneral MedicineProstheses and ImplantsPolyethylenechemistryPolyethyleneMicroscopy Electron ScanningHigh-density polyethyleneImplantOxidation-ReductionBiotechnologyActa biomaterialia
researchProduct

Additive Manufacturing of Multi‐Scale Porous Soft Tissue Implants That Encourage Vascularization and Tissue Ingrowth

2021

Medical devices, such as silicone-based prostheses designed for soft tissue implantation, often induce a suboptimal foreign-body response which results in a hardened avascular fibrotic capsule around the device, often leading to patient discomfort or implant failure. Here, it is proposed that additive manufacturing techniques can be used to deposit durable coatings with multiscale porosity on soft tissue implant surfaces to promote optimal tissue integration. Specifically, the “liquid rope coil effect”, is exploited via direct ink writing, to create a controlled macro open-pore architecture, including over highly curved surfaces, while adapting atomizing spray deposition of a silicone ink t…

Materials scienceSwinesoft tissue implantsmedical grade siliconeSiliconesBiomedical EngineeringTissue integrationPharmaceutical Science02 engineering and technology010402 general chemistry01 natural sciencesBiomaterialsMedical grade siliconechemistry.chemical_compoundSiliconeSettore BIO/10 - BiochimicaMaterials TestingAnimalsHumansPorosityImplant failureSoft tissueProstheses and Implantsmedical device coatings021001 nanoscience & nanotechnology0104 chemical scienceschemistrydevice-tissue interactionImplant0210 nano-technologyadditive manufacturingPorosityTissue ingrowthBiomedical engineeringAdvanced Healthcare Materials
researchProduct