Search results for "Prosthesis"

showing 10 items of 719 documents

Portraying infective endocarditis

2019

Infective endocarditis is a growing problem with many shifts due to ever-increasing comorbid illnesses, invasive procedures, and increase in the elderly. We performed this multinational study to depict definite infective endocarditis. Adult patients with definite endocarditis hospitalized between January 1, 2015, and October 1, 2018, were included from 41 hospitals in 13 countries. We included microbiological features, types and severity of the disease, complications, but excluded therapeutic parameters. A total of 867 patients were included. A total of 631 (72.8%) patients had native valve endocarditis (NVE), 214 (24.7%) patients had prosthetic valve endocarditis (PVE), 21 (2.4%) patients …

MaleInternationalityAucunInfective endocarditimedicine.disease_causeMedical microbiology80 and overBlood cultureHospital MortalityAged 80 and overmedicine.diagnostic_testbiologyEndocarditisSBacterialGeneral MedicineSciences bio-médicales et agricolesMiddle AgedStaphylococcal InfectionsSciences du Vivant [q-bio]/Microbiologie et ParasitologieViridans StreptococciCatheterInfectious Diseases[SDV.MP]Life Sciences [q-bio]/Microbiology and ParasitologyStaphylococcus aureusInfective endocarditisAortic ValveMitral ValveFemaleMicrobiology (medical)Adultmedicine.medical_specialtyProsthesis-Related InfectionsAdolescentaureusBlood cultureYoung AdultInternal medicinemedicineEndocarditisHumansresults of multinational ID-IRI study- EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES cilt.38 ss.1753-1763 2019 [Erdem H. Puca E. Ruch Y. Santos L. Ghanem-Zoubi N. Argemi X. Hansmann Y. Guner R. Tonziello G. Mazzucotelli J. et al. -Portraying infective endocarditis]ProstheticAgedNative Valve EndocarditisBacteriabusiness.industryEndocarditis Bacterialmedicine.diseasebiology.organism_classificationS. aureusViridans streptococciInfective endocarditisbusinessNative
researchProduct

A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma

2014

Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…

MaleIntraocular pressureVisual acuityMinimally invasive glaucoma surgerymedicine.medical_treatmentVisual AcuityGlaucomalaw.inventionRandomized controlled trialLens Implantation Intraocularlaw80 and overMedicineSingle-Blind MethodProspective StudiesProspective cohort studyGlaucoma Drainage ImplantsAged 80 and overIntraocularMedicine (all)Adult; Aged; Aged 80 and over; Antihypertensive Agents; Female; Follow-Up Studies; Glaucoma Open-Angle; Humans; Intraocular Pressure; Lens Implantation Intraocular; Limbus Corneae; Male; Middle Aged; Prospective Studies; Prosthesis Implantation; Single-Blind Method; Tonometry Ocular; Visual Acuity; Visual Fields; Young Adult; Glaucoma Drainage Implants; Phacoemulsification; Stents; Ophthalmology; Medicine (all)Middle AgedOpen-AngleFemaleStentsmedicine.symptomLens ImplantationGlaucoma Open-AngleAdultmedicine.medical_specialtyLimbus CorneaeTonometryProsthesis ImplantationTonometry OcularYoung AdultOphthalmologyOcularHumansAntihypertensive AgentsIntraocular PressureAgedPhacoemulsificationbusiness.industryGlaucomaPhacoemulsificationCataract surgerymedicine.diseaseOphthalmologyVisual FieldsbusinessFollow-Up Studies
researchProduct

Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.

2020

OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…

MaleKeratoconusmedicine.medical_specialtyVisual acuitygenetic structuresContact LensesProsthesis Designlaw.inventionCorneal Diseases03 medical and health sciences0302 clinical medicineScleral lenslawOphthalmologyProsthesis FittingmedicineHumansbusiness.industryDaily wearmedicine.diseaseeye diseasesLens (optics)Ophthalmology030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessOcular surface030217 neurology & neurosurgeryScleraEyecontact lens
researchProduct

Comparison of 2 Zero-Profile Implants in the Treatment of Single-Level Cervical Spondylotic Myelopathy: A Preliminary Clinical Study of Cervical Disc…

2016

Objectives Cervical disc arthroplasty (CDA) with Discover prosthesis or anterior cervical discectomy and fusion (ACDF) with Zero-P cage has been widely used in the treatment of cervical spondylotic myelopathy (CSM). However, little is known about the comparison of the 2 zero-profile implants in the treatment of single-level CSM. The aim was to compare the clinical outcomes and radiographic parameters of CDA with Discover prosthesis and ACDF with Zero-P cage for the treatment of single-level CSM. Methods A total of 128 consecutive patients who underwent 1-level CDA with Discover prosthesis or ACDF with Zero-P cage for single-level CSM between September 2009 and December 2012 were included in…

MaleKinematicsPhysiologymedicine.medical_treatmentlcsh:MedicineAnterior cervical discectomy and fusionOssificationProsthesisLaryngology0302 clinical medicineMedicine and Health SciencesMedicine030212 general & internal medicineRange of Motion Articularlcsh:ScienceIntervertebral DiscProstheticsMultidisciplinaryPhysicsClassical MechanicsDysphagiaProstheses and ImplantsMiddle Agedmedicine.anatomical_structureTreatment OutcomeConnective TissueSpinal fusionPhysical SciencesCervical VertebraeFemaleBone RemodelingAnatomyRange of motionCervical vertebraeResearch ArticleBiotechnologyDiskectomyAdultmedicine.medical_specialtySurgical and Invasive Medical ProceduresSpinal Cord DiseasesArthroplasty03 medical and health sciencesMusculoskeletal System ProceduresFunctional spinal unitHumansArthroplasty ReplacementLigamentsbusiness.industrylcsh:RBiology and Life SciencesIntervertebral discArthroplastySurgeryBiological TissueSpinal FusionOtorhinolaryngologylcsh:QMedical Devices and EquipmentSpondylosisbusinessPhysiological Processes030217 neurology & neurosurgeryPLoS ONE
researchProduct

Long-Term Results After Repair of Type A Acute Aortic Dissection According to False Lumen Patency

2009

Background Late survival and freedom from retreatment on the descending aorta was evaluated after ascending aortic repair for type A acute aortic dissection (TAAAD). Methods Between March 1992 and January 2006, 189 TAAAD patients (mean age, 52 ± 11; range, 17 to 83 years) were included; of these, 58 had a patent false lumen, and 49 had Marfan syndrome. The descending aorta was evaluated postoperatively with computed tomography (CT). Late outcomes were assessed by Cox regression analysis and actuarial survival and freedom from retreatment by the Kaplan-Meier method. Mean follow-up was 88 ± 44 months. Results There were 38 (20%) late deaths. At 10 years, survival was 89.8% ± 2.1% for patients…

MaleMarfan syndromeTime FactorsThoracicAortic aneurysm80 and overHospital MortalityTomographyAged 80 and overAortic dissectionMiddle AgedhumanitiesAcute Disease; Adolescent; Aged; Aged 80 and over; Aneurysm Dissecting; Aortic Aneurysm Thoracic; Blood Vessel Prosthesis Implantation; Female; Follow-Up Studies; Hospital Mortality; Humans; Italy; Male; Middle Aged; Retrospective Studies; Survival Rate; Time Factors; Tomography X-Ray Computed; Treatment Outcome; Young AdultAortic AneurysmX-Ray ComputedSurvival RateTreatment OutcomeItalyCardiothoracic surgeryDescending aortaAcute DiseaseCirculatory systemCardiologyFemaleCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialtyAdolescentBlood Vessel Prosthesis ImplantationYoung AdultAneurysmmedicine.arteryInternal medicinemedicineHumansAgedRetrospective StudiesAortaAortic Aneurysm Thoracicbusiness.industrynutritional and metabolic diseasesSettore MED/23 - Chirurgia Cardiacamedicine.diseaseAneurysmSurgeryAortic DissectionSurgeryTomography X-Ray ComputedbusinessDissectingFollow-Up StudiesThe Annals of Thoracic Surgery
researchProduct

Reliability of Two Color Selection Devices in Matching and Measuring Tooth Color

2011

ABSTRACT Objective The objective of this study was to investigate the intra and interdevice reliability of two tooth color measurement devices: EasyShade (ES) and SpectroShade Micro (SSM). Materials and methods Tooth color was measured in six maxillary and mandibular. L*, a* and b* values and shade matches to VITA Classical and Vitapan 3D-Master shade guide systems were determined for all teeth. ÄE was assessed. Paired t-test and correlation coefficient (ICC) were used. Results Intradevices no significant differences (p &gt; 0.05) were found between L*, a*, b*. Interdevice L* and b* were significantly higher for ES (p &lt; 0.05), while a* was significantly higher for SSM (p &lt; 0.05). ÄE s…

MaleMatching (statistics)Correlation coefficientProsthesis Coloringbusiness.industryColorReproducibility of ResultsYoung AdultSpectrophotometryStatisticsHumansTooth colorMedicineFemaleLaboratory researchbusinessToothGeneral DentistryReliability (statistics)The Journal of Contemporary Dental Practice
researchProduct

Pharmacokinetics of methylmethacrylate monomer during total hip replacement in man.

1988

The concentration of methylmethacrylate monomer (MMA) in the blood stream after implantation of the components of 15 total hip prostheses using bone cement was determined in the pulmonary artery, the radial artery, and the superior vena cava after cement application, and correlated with the observed drop in blood pressure and the increase in the pulmonary arterial pressure. In all samples MMA was found. The values ranged from 0.02 micrograms/ml to 59 micrograms/ml. The mean maximum value after implantation of the stem was measured to be 7.8 micrograms/ml in the pulmonary artery, 4.6 micrograms/ml in the radial artery, and 1.75 micrograms/ml in the superior vena cava. After implantation of t…

MaleMean arterial pressureChromatography GasVena Cava SuperiorBlood PressurePulmonary ArteryPharmacokineticsSuperior vena cavamedicine.arterymedicineHumansMethylmethacrylatesOrthopedics and Sports MedicineRadial arteryAgedAged 80 and overbusiness.industryGeneral MedicineMiddle AgedBone cementBlood pressureAnesthesiaCirculatory systemPulmonary arterySurgeryFemaleHip ProsthesisNuclear medicinebusinessArchives of orthopaedic and traumatic surgery. Archiv fur orthopadische und Unfall-Chirurgie
researchProduct

Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Pati…

2020

Background and objectives: To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator&reg

MaleMedicine (General)Dental WearDentistryoverdentureODB++ArticlebarCohort StudiesDental Prosthesis Retentionlocator03 medical and health sciencesR5-9200302 clinical medicinePatient satisfactionSurveys and QuestionnairesmedicineHumansDental Restoration FailureProspective StudiesProspective cohort studyAgedMechanical PhenomenaDental ImplantsEdentulismbusiness.industry030206 dentistrymedicine.diseaseDenture Overlayclinical outcomesTreatment OutcomeScrew looseningPatient SatisfactionAutomotive Engineeringdental implants; overdenture; locator; bar; clinical outcomesFemaleDental Prosthesis Implant-SupportedMouth Edentulousbusiness030217 neurology & neurosurgeryImplant supportedCohort studyFollow-Up StudiesMedicina (Kaunas, Lithuania)
researchProduct

A Comparison of 2 Mitral Annuloplasty Rings for Severe Ischemic Mitral Regurgitation: Clinical and Echocardiographic Outcomes.

2016

Controversies regarding the choice of annuloplasty rings for treatment of ischemic mitral regurgitation still exist. Aim of the study is to compare early performance of 2 different rings in terms of rest and exercise echocardiographic parameters (transmitral gradient, systolic pulmonary artery pressure, and mitral valve area), clinical outcomes, and recurrence of mitral regurgitation. From January 2008 till December 2013, prospectively collected data of patients who underwent coronary artery bypass grafting and undersizing mitral valve annuloplasty for severe chronic ischemic mitral regurgitation at our Institution were reviewed. A total of 93 patients were identified; among them 44 had sem…

MaleMitral Valve AnnuloplastyTime FactorsMyocardial IschemiaHemodynamics030204 cardiovascular system & hematologySeverity of Illness IndexVentricular Function Left0302 clinical medicinePostoperative ComplicationsRecurrenceMitral valve annuloplastyMitral valve030212 general & internal medicineHospital MortalityHeart Valve Prosthesis ImplantationExercise ToleranceIschemic mitral regurgitationMitral Valve InsufficiencyGeneral MedicineMiddle Agedmedicine.anatomical_structureTreatment OutcomeItalyHeart Valve ProsthesisCardiologyMitral ValveFemaleCardiology and Cardiovascular MedicineArteryEchocardiography StressPulmonary and Respiratory Medicinemedicine.medical_specialtyProsthesis Design03 medical and health sciencesInternal medicinemedicine.arterymedicineHumansMitral AnnuloplastyAgedRetrospective StudiesMitral regurgitationbusiness.industryRecovery of FunctionSurgeryPulmonary arteryChronic DiseaseExercise TestSurgerybusinessSeminars in thoracic and cardiovascular surgery
researchProduct

Patient-Specific Rehearsal Feasibility Before Endovascular Repair of Ruptured Abdominal Aortic Aneurysm.

2019

Purpose: To evaluate the feasibility of a patient-specific rehearsal (PsR) before emergency endovascular aneurysm repairs (eEVAR) and its influence on the operation. Materials and Methods: From February 2016 to October 2016, 10 consecutive patients (mean age 75 +/- 7.4 years; 9 men) presenting with a ruptured abdominal aortic aneurysm (rAAA) suitable for standard EVAR were enrolled in the study. A 3-dimensional (3D) model of the abdominal aorta was generated on a virtual reality simulator based on the patient's computed tomography (CT) images. Following the patient-specific simulation setup, PsR was conducted during patient admission or in parallel with the preoperative eEVAR workup. Measur…

MaleModels AnatomicPatient-Specific Modelingmedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic RuptureOperative TimeProsthesis DesignSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repairBlood Vessel Prosthesis Implantationabdominal aortic aneurysmAneurysmPostoperative ComplicationsRisk Factorsmedicine.arterymedicineHumansRadiology Nuclear Medicine and imagingpatient-specific rehearsalAgedAged 80 and overruptured aneurysmRuptured abdominal aortic aneurysmbusiness.industryAbdominal aortaEndovascular ProceduresModels CardiovascularPerioperativesimulationmedicine.diseaseAbdominal aortic aneurysmConfidence intervalBlood Vessel ProsthesisTreatment OutcomeSurgery Computer-AssistedPrinting Three-DimensionalFeasibility StudiesSurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicineComplicationbusinessAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct