Search results for "Prosthesis"

showing 10 items of 719 documents

Incidence of thromboembolic complications in patients with atrial fibrillation or mechanical heart valves with a subtherapeutic international normali…

2012

Subtherapeutic international normalized ratio (INR) is frequently encountered in clinical practice, and patients with high-risk atrial fibrillation (AF) and with mechanical heart valve (MHV) with inadequate anticoagulation may be exposed to an increased risk of thromboembolic events (TE). However, there are no prospective data evaluating this risk. Consecutive patients with a history of stable anticoagulation, but with a subtherapeutic INR, were prospectively included. Data on use and dose of low-molecular weight heparin (LMWH) bridging therapy were collected. The incidence of objectively confirmed TE and of major bleeding events within 90 days after the index INR was assessed. Five hundred…

MaleRiskmedicine.medical_specialtyPopulationvenous thromboembolismHemorrhageComorbidityThrombophiliaFollow-Up StudiePostoperative ComplicationsInternal medicineThromboembolismAtrial FibrillationmedicineHumansThrombophiliaProspective StudiesInternational Normalized RatioeducationProspective cohort studyAgedAged 80 and overHeart Valve Prosthesis Implantationeducation.field_of_studybusiness.industryIncidence (epidemiology)IncidenceMedicine (all)WarfarinAnticoagulantAnticoagulantsAtrial fibrillationHematologyHeparin Low-Molecular-WeightMiddle Agedmedicine.diseaseConfidence intervalSurgeryProspective StudieHeart Valve ProsthesiHeart Valve ProsthesisFemalePostoperative ComplicationWarfarinbusinessCohort studymedicine.drugFollow-Up StudiesHuman
researchProduct

Intraperitoneal coated polypropylene hernia meshes: the dark side of the moon.

2014

To date, the use of meshes in repairing abdominal wall defects has brought many advantages, especially in terms of recurrence prevention, but it is not exempt from complications, such as chronic pain, entero-cutaneous fistulas and intestinal obstruction. Here we report a case of intestinal obstruction in a patient with a large umbilical hernia treated laparoscopically by means of a composite polypropylene mesh, six year before.A 49-year-old man came to our care with a 3-day history of central and right lower abdominal quadrant pain and a clinical picture of intestinal obstruction. Six years before the patient underwent a laparoscopic intervention to repair his umbilical hernia, with the pos…

MaleSettore MED/18 - Chirurgia Generalehernia complications polypropylene coated hernia mesh small bowel obstruction small bowel resection umbilical herniaHumansLaparoscopyJejunal DiseasesMiddle AgedSurgical MeshPolypropylenesProsthesis DesignHernia UmbilicalHerniorrhaphyIntestinal ObstructionAnnali italiani di chirurgia
researchProduct

Five-Year Results of the Bioflow-III Registry:Real-World Experience with a Biodegradable Polymer Sirolimus-Eluting Stent

2018

Abstract Purpose We aimed to assess long-term safety and performance of the Orsiro sirolimus-eluting coronary stent with biodegradable polymer in a large unselected population and in pre-specified subgroups. Methods BIOFLOW-III is a prospective, multicenter, international, observational registry with follow-up visits scheduled at 6 and 12 months, and at 3 and 5 years ( NCT01553526 ). Results 1356 patients with 1738 lesions were enrolled. Of those, 392 (28.9%) declined to participate in the study extension from 18 months to 5 years, 37 (2.7%) withdrew consent, and 89 (6.6%) were lost to follow-up. At 5-years, Kaplan-Meier estimates of target lesion failure, defined as a composite of cardiac …

MaleTarget lesionTime Factorsmedicine.medical_treatmentMyocardial InfarctionCoronary Artery Disease030204 cardiovascular system & hematology0302 clinical medicineRecurrenceRisk FactorsAbsorbable ImplantsBiodegradable polymerProspective StudiesRegistries030212 general & internal medicineMyocardial infarctionAngioplasty Balloon Coronaryeducation.field_of_studyDiabetesDrug-Eluting StentsGeneral MedicineCoronary artery stenosisMiddle AgedTreatment OutcomeDrug-eluting stentFemaleCardiology and Cardiovascular Medicinemedicine.medical_specialtyPolyestersPopulationHybrid stentProsthesis Design03 medical and health sciencesDiabetes mellitusCoronary stentmedicineHumanseducationAgedSirolimusbusiness.industryCoronary ThrombosisStentCardiovascular Agentsmedicine.diseaseConfidence intervalSurgeryCoronary OcclusionChronic DiseaseDrug-eluting stentbusiness
researchProduct

Effects of combined therapy of clopidogrel and aspirin in preventing thrombus formation on mechanical heart valves in an ex vivo rabbit model.

2002

Abstract Background: The aim of our study was to investigate the efficacy of the combination of clopidogrel and aspirin in the prevention of thrombus formation on artificial heart valves in an experimental rabbit model as compared to anticoagulation with warfarin. Methods: Studies were performed after oral administration of clopidogrel and aspirin in group I (n=9) for 5 days, after 5±2 days treatment with warfarin in group II (n=9) and without medication in group III (n=9). Leaflets from Sulzer Carbomedics bileaflet valves were placed in a flow chamber. The flow chamber was filled with blood in a continuous circulation between the carotid artery and the jugular vein. Results: In group III, …

MaleTiclopidineArtificial heart valveDrug Evaluation PreclinicalIn Vitro Techniquesmedicine.disease_causeJugular veinmedicineAnimalscardiovascular diseasesHeart valveThrombusAspirinAspirinbusiness.industryWarfarinThrombosisHematologymedicine.diseaseClopidogrelThrombosisClopidogrelMicroscopy Electronmedicine.anatomical_structureAnesthesiaHeart Valve Prosthesiscardiovascular systemDrug Therapy CombinationRabbitsWarfarinbusinessmedicine.drugThrombosis research
researchProduct

Valve prosthesis-patient mismatch: hemodynamic, echocardiographic and clinical consequences

2011

OBJECTIVES: The purpose is to evaluate in vivo at rest and under stress conditions hemodynamic performance of the small size St. Jude Medical Regent (SJMR) prosthetic valve in patients with a body surface area (BSA) of 1.8 ± 0.11 m(2) and to define the role of valve prosthesis- patient mismatch on left ventricular mass regression following aortic valve replacement. METHODS: We evaluated 25 cases (12 males and 13 females, mean age 65.2 ± 8 years) of aortic valve replacement (17 mm SJMR in three cases and 19 mm SJMR in 22 cases). All the patients underwent at rest Doppler echocardiography before and after surgery and both basal and dobutamine stress echocardiography (DSE) at follow-up. The me…

MaleTime FactorsBody Surface Areamedicine.medical_treatmentLeft ventricular maHemodynamicsDoppler echocardiographyVentricular Function LeftValve replacementAortic valve replacementDobutamineCardiac skeletonBody surface areaHeart Valve Prosthesis ImplantationEjection fractionmedicine.diagnostic_testVentricular RemodelingMiddle AgedEchocardiography DopplerTreatment OutcomeAortic ValveHeart Valve ProsthesisCardiologyFemaleHypertrophy Left VentricularCardiology and Cardiovascular MedicineEchocardiography StressPulmonary and Respiratory Medicinemedicine.medical_specialtyProsthesis DesignPreoperative carePredictive Value of TestsInternal medicineProsthesis-patient mismatch; Left ventricular mass; Effective orifice area; DobutaminemedicineHumansAgedRetrospective StudiesChi-Square Distributionbusiness.industryHemodynamicsProsthesis-patient mismatchStroke VolumeSettore MED/23 - Chirurgia CardiacaAortic Valve StenosisRecovery of Functionmedicine.diseaseEffective orifice areaSurgerybusiness
researchProduct

A multicenter 12-month experience with a new iliac side-branched device for revascularization of hypogastric arteries.

2016

Abstract Objective The aim of this study was to investigate the 1-year safety and efficacy of a new iliac side-branched device (IBD) for revascularization of the hypogastric arteries. Methods Patients receiving the E-liac (Jotec GmbH, Hechingen, Germany) side-branched device at six German vascular centers either as a stand-alone procedure or in combination with abdominal aortic aneurysm exclusion were included in a prospectively created data bank. Collected data were analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) patency. Results Between January 2012 and January 2015, a total of…

MaleTime FactorsDatabases FactualEndoleakComputed Tomography Angiographymedicine.medical_treatmentBlood Loss Surgical030204 cardiovascular system & hematologyEndovascular aneurysm repair030218 nuclear medicine & medical imaging0302 clinical medicineRisk FactorsGermanyMedicineHospital MortalityAged 80 and overEndovascular ProceduresGraft Occlusion VascularArteriesMiddle AgedCommon iliac arteryInternal iliac arteryAbdominal aortic aneurysmTreatment OutcomeIliac AneurysmFemaleStentsRadiologyCardiology and Cardiovascular Medicinemedicine.medical_specialtyRevascularizationProsthesis DesignPelvis03 medical and health sciencesBlood Vessel Prosthesis ImplantationAneurysmBlood vessel prosthesismedicine.arteryHumansVascular PatencyAgedRetrospective Studiesbusiness.industryExternal iliac arteryAngiography Digital Subtractionmedicine.diseaseSurgeryBlood Vessel ProsthesisFeasibility StudiesSurgerybusinessJournal of vascular surgery
researchProduct

A 15-Year Single-Center Experience of Endovascular Repair for Elective and Ruptured Abdominal Aortic Aneurysms

2016

Purpose: To evaluate the differences in technical outcomes and secondary interventions between elective endovascular aneurysm repair (el-EVAR) procedures and those for ruptured aneurysms (r-EVAR). Methods: Of the 906 patients treated with primary EVAR from September 1998 until July 2012, 43 cases were excluded owing to the use of first-generation stent-grafts. Among the remaining 863 patients, 773 (89.6%) patients (mean age 72 years; 697 men) with asymptomatic or symptomatic abdominal aortic aneurysms (AAAs) were assigned to the el-EVAR group; 90 (10.4%) patients (mean age 73 years; 73 men) were assigned to the r-EVAR group based on blood outside the aortic wall on preoperative imaging. Th…

MaleTime FactorsDatabases Factualmedicine.medical_treatmentKaplan-Meier Estimate030204 cardiovascular system & hematologySingle CenterEndovascular aneurysm repairendovascular aneurysm repairPostoperative Complications0302 clinical medicineRisk Factors030212 general & internal medicineNetherlandsAged 80 and overmedicine.diagnostic_testruptured aneurysmEndovascular ProceduresMiddle AgedAbdominal aortic aneurysmTreatment OutcomeElective Surgical ProceduresreinterventionsFemaleStentsmedicine.symptomCardiology and Cardiovascular Medicinemedicine.medical_specialtyAortographycomplicationsAortic RuptureendoleakProsthesis DesignAortographyAsymptomaticDisease-Free SurvivalBlood Vessel Prosthesis Implantation03 medical and health sciencesabdominal aortic aneurysmBlood vessel prosthesismedicineHumansRadiology Nuclear Medicine and imagingAortic ruptureAgedRetrospective Studiesstent-graftbusiness.industryRetrospective cohort studymedicine.diseaseBlood Vessel ProsthesisSurgerySurgeryEmergenciesbusinessAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case-control study.

2016

Aim To describe the long-term experience of a simplified frozen elephant trunk technique (sFETT) used in complicated acute type A aortic dissection (AAAD) treatment. Methods and results Between January 2001 and December 2012, 34 patients (mean age 59.9 ± 11.0 years) with complicated AAAD (DeBakey I) underwent an emergency surgery including sFETT. sFETT consisted in gluing the dissected aortic arch wall layers with gelatine-resorcinol adhesive and video-assisted antegrade open arch aortic stent-graft deployment in the arch or proximal descending aorta. In addition to sFETT, the aortic root was addressed with standard techniques. A 30-day mortality was 14.7% (five patients) due to bleeding (1…

MaleTime FactorsElephant trunksComputed Tomography AngiographyVideo-Assisted SurgeryKaplan-Meier Estimate030204 cardiovascular system & hematologyComplicated acute type A aortic dissectionSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicinePostoperative ComplicationsRisk Factorsfrozen elephant trunkComputed tomography angiographyAortic dissectionAged 80 and overmedicine.diagnostic_testMedicine (all)Endovascular ProceduresGeneral MedicineMiddle AgedAortic AneurysmTreatment OutcomeAcute typeAcute DiseaseFemaleStentsCardiology and Cardiovascular MedicineAdultReoperationmedicine.medical_specialtyAortographyProsthesis DesignAortography03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicineHumansRadiology Nuclear Medicine and imagingAgedRetrospective StudiesComplicated acute type A aortic dissection; frozen elephant trunk; Surgery; Medicine (all); Radiology Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicinebusiness.industryLong term resultsmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic Dissection030228 respiratory systemSurgeryTissue AdhesivesEmergenciesbusinessVascular
researchProduct

Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients

2017

Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…

MaleTime FactorsEndoleakComputed Tomography Angiographymedicine.medical_treatmentMid term resultsKaplan-Meier Estimate030204 cardiovascular system & hematologySettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsOcclusionMedicine030212 general & internal medicineAortic arch aneurysm; Chimney graft/technique; Endoleak; Endovascular aneurysm repair; Parallel graft; Periscope graft; Surgery; Cardiology and Cardiovascular MedicineAged 80 and overeducation.field_of_studyHigh risk patients10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Aged2746 SurgeryTreatment Outcomecardiovascular systemFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyPopulation610 Medicine & healthProsthesis DesignAortographyRisk AssessmentDisease-Free Survival2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationEndovascular aneurysm repair03 medical and health sciencesAneurysmmedicine.arteryHumanseducationAgedRetrospective StudiesAortaAortic Aneurysm ThoracicParallel graftAortic arch aneurysmbusiness.industryPatient SelectionChimney graft/techniquemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac SurgerySurgeryPeriscope graftSurgerybusinessEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Hybrid Endograft Solution for Complex Iliac Anatomy

2010

The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…

MaleTime FactorsOCCLUSIONmedicine.medical_treatmentSettore MED/22 - Chirurgia VascolareEndovascular aneurysm repairendovascular aneurysm repairAortic aneurysmOcclusionEVARAged 80 and overOUTCOMESmedicine.diagnostic_testGeneral MedicineAnatomyAbdominal aortic aneurysmTreatment OutcomeElective Surgical ProceduresFemaleRadiologyCardiology and Cardiovascular MedicineElective Surgical Proceduremedicine.medical_specialtyAortographyProsthesis DesignAortographyIliac ArteryBlood Vessel Prosthesis Implantationabdominal aortic aneurysm endovascular aneurysm repair Excluder limbs hybrid graft iliac tortuosityabdominal aortic aneurysmBlood vessel prosthesismedicineHumansExcluder limbsRadiology Nuclear Medicine and imagingAgedRetrospective Studiesbusiness.industryENDOVASCULAR REPAIRAORTIC-ANEURYSM REPAIRmedicine.diseaseSurgeryBlood Vessel Prosthesisiliac tortuosityFeasibility StudiesSurgeryhybrid graftSTENT-GRAFTSbusinessTomography X-Ray ComputedAbdominal surgeryAortic Aneurysm AbdominalVascular
researchProduct