Search results for "Prosthesis"
showing 10 items of 719 documents
Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multi…
2020
Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-rel…
Modes of periacetabular load transfer to cortical and cancellous bone after cemented versus uncemented total hip arthroplasty: A prospective study us…
2008
Stress-shielding and periprosthetic bone loss after total hip arthroplasty (THA) may be clinically relevant for high-demand patients. Analysis of cortical and cancellous bone density (BD) changes in vivo after THA is of interest to basic science researchers and joint reconstruction surgeons. An insufficient periprosthetic bone stock may predispose to migration, early mechanical failure, and major problems in revision surgery. We used computed tomography (CT)-assisted osteodensitometry in two prospectively analyzed cohorts after cemented (n = 21) versus noncemented (n = 23) cup fixation. Periacetabular BD (mgCaHa/mL) was determined in five CT scans cranial and five CT scans at the level of t…
Patients with bicuspid aortic valve are likely to receive an aortic valve prosthesis during prophylactic resection of their ascending aortic aneurysm.
2015
This study aims to evaluate whether thepresence or discovery of a BAV under ATAA repair would impactthe decision-making of the surgical procedure choice.
Decellularized tracheal prelamination implant: A proposed bilateral double organ technique
2021
Introduction In tracheal replacement transplantation, prelamination is a critical stage. Nowadays, the most widely used prelamination technique is the prethoracic fascia flap with lateral thoracic artery. We propose a flap based on the internal thoracic artery, which allows a relatively non-aggressive double organ implant, and we have tested its efficacy in decellularized tracheas. Material and methods Tracheas of albino New Zealand rabbits were decellularized following a protocol that uses detergents and cryogenization, sterilized with 1kGy gamma radiation and tutorized with a stent. Bilateral pedicled flaps made of pectoral fascia and a muscular component were harvested through a longitud…
Pathogenesis and prophylaxis of circulatory reactions during total hip replacement
1993
Circulatory reactions such as a drop in blood pressure, bradycardia, cardiac arrest, and even intraoperative death after insertion of the stem are well known events during total hip replacement. The present paper reports bone marrow intravasation after rise of intramedullary pressure in the femoral cavity during insertion of hip prostheses, demonstrated by intraoperative transesophageal echocardiography. In an animal study, the ultrasound echoes were identified as "mixed emboli" consisting of a core of bone marrow surrounded by thrombus. These results suggested the use of an intramedullary plug to restrict the intravasation of bone marrow. A trial was undertaken in 60 total hip replacement …
Tumor Marker Carbohydrate Antigen 125 Predicts Adverse Outcome After Transcatheter Aortic Valve Implantation
2013
ObjectivesThis study sought to predict the value of tumor marker carbohydrate antigen 125 (CA125) before and after transcatheter aortic valve implantation (TAVI) for all-cause death and a composite endpoint of death, admission for heart failure, myocardial infarction, and stroke (major adverse cardiac events [MACE]).BackgroundRisk stratification after TAVI remains challenging. The use of biomarkers in this setting represents an unmet need.MethodsCA125 was measured in 228 patients before and after TAVI. The association with outcomes was assessed using parametric Cox regression and joint modeling for baseline and longitudinal analyses, respectively. CA125 was evaluated as logarithm transforma…
Cardiopulmonary Hemodynamic Profile Predicts Mortality After Transcatheter Tricuspid Valve Repair in Chronic Heart Failure.
2020
This study was designed to assess hemodynamic changes in response to transcatheter tricuspid valve edge-to-edge repair (TTVR) and to identify hemodynamic predictors associated with mortality.Severe tricuspid regurgitation (TR) is associated with high mortality. TTVR effectively alleviates heart failure symptoms, but comprehensive hemodynamic characterization of patients undergoing TTVR is currently lacking.This international, multicenter study included 236 patients undergoing TTVR. Data from clinical assessment, echocardiography, intraprocedural right heart catheterization, and noninvasive cardiac output measurement were analyzed. Hemodynamic predictors for mortality were identified using l…
Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
2013
Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…
Transcatheter Mitral Valve Repair: Single Stage Combo Approach
2019
Initial Experience in the Treatment of Extensive Iliac Artery Aneurysms With the Nellix Aneurysm Sealing System.
2016
Purpose: To assess the feasibility and effectiveness of the Nellix prosthesis in the treatment of common iliac artery aneurysms. Methods: Between May 2013 and June 2015, 230 patients underwent implantation of the Nellix device at 2 institutions. Fifty of these patients (mean age 76 years; 35 men) were identified as having 60 common iliac artery aneurysms (CIAAs) with a median diameter of 4 cm (range 3.5–7). The majority of patients had aortoiliac aneurysms (5, 70%), 10 (20%) had isolated CIAAs, and 5 (10%) had iliac anastomotic aneurysms after aortoiliac bypass. In 20 patients, the iliac aneurysm was the indication for the intervention; in the other 30 patients, the endovascular iliac repa…