Search results for "Prosthesis"
showing 10 items of 719 documents
Effect of large positioning holes on capsule fixation of plate-haptic intraocular lenses
2000
Abstract Purpose To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. Setting Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. Methods In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted under standardized conditions by the same surgeon. The IOL position was documented at the end of surgery and by retroillumination on the first day and 5 months postoperatively. The positioning-hole area was evaluated by ultrasound biomicroscopy (50 MHz) 5 months postoperatively. Results One day postoperatively, no IOL in either group was decentered more than 1.0 mm. Aft…
One-Year Outcomes with New-Generation Multifocal Intraocular Lenses
2007
Purpose: To compare new-generation multifocal intraocular lenses (IOLs) with monofocal IOLs. Design: Randomized prospective clinical trial. Participants: Sixty-two consecutive patients with cataract, seen between January of 2005 and January of 2006 at the Department of Ophthalmology of Palermo University Hospital in Italy, were bilaterally implanted with monofocal (AR 40, Advanced Medical Optics [AMO], Santa Ana, CA; 15 patients), multifocal refractive (Array SA40N, AMO; 16 patients), multifocal refractive (ReZoom, AMO; 15 patients), or multifocal diffractive pupil-independent (Tecnis ZM900, AMO; 16 patients) IOLs. Intervention: Bimanual phacoemulsification. Main Outcome Measures: Primary o…
Surgical conversion with graft salvage as a definitive treatment for persistent type II endoleak causing sacenlargement
2015
Objective The goal of this study was to present open surgical conversion with graft salvage or "semiconversion" as a definitive and safe treatment for untreatable and persistent type II endoleaks causing sac enlargement after endovascular aneurysm repair. Methods Between January 2001 and December 2014, 25 of 1623 endovascular aortic repair (EVAR) patients were selected as candidates for open semiconversion. The indication was persistent type II endoleak in 13 patients (12 of whom received previous attempts of embolization), type I and II endoleak in 2 patients, and sac growth without imaging evidence of endoleak in the other 10. After the infrarenal aorta was prepared (via a retroperitoneal…
Enhanced angiogenesis in the 3D dynamic responsive implant for inguinal hernia repair ProFlor
2021
Biologic response to hernia prostheses represents a continuous source of debate. Conventional hernia meshes, in their typical static, passive configuration have been used for decades to reinforce the herniated abdominal wall. These flat implants, mainly fixated with sutures or tacks, induce poor quality fibrotic ingrowth that shrinks the mesh. In groin hernia repair, flat meshes are applied in the delicate inguinal surrounding where uncontrolled development of a scar plate can impair movement and may incorporate the sensitive nerves crossing this area. Complications deriving from mesh fixation and nerve entrapment are frequent and unpleasant for patients. To remedy these problems, a multila…
Complications of guided surgery and immediate loading in oral implantology: a report of 12 cases.
2011
Objectives: The growing interest in minimally invasive surgery, together with the possibility of fitting prostheses with immediate function, have led to the development of software capable of planning and manufacturing a surgical guide and prosthesis that can be placed upon conclusion of the implant surgery step. The present study evaluates the surgical and prosthetic complications of implant treatment with the guided surgery technique, together with patient comfort during and after treatment. Patients and methods: A retrospective observational study was made of 19 patients with partially or totally edentulous upper and/or lower maxillae, involving the placement of a total of 122 implants. …
Effect of a closed foldable equator ring on capsular bag shrinkage in cataract surgery.
2005
To evaluate the effect of a closed foldable equator ring (CFER) versus a conventional capsular tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.In this prospective study, 70 eyes of 70 patients were randomized to 2 groups using a 1:1 block scheme. After uneventful cataract surgery, a capsular measuring ring was implanted in all eyes to measure the capsular bag diameter in vivo. In Group 1, a CTR was implanted in the capsular bag. In Group 2, a CFER was inserted. Biometric characteristics such as axial length and the horizontal and vertical corneal radii were measured preoperatively. The capsular bag diameter and capsulor…
Sphincter-like motion following machanical dilation of the internal inguinal ring during indirect inguinal hernia procedure
2008
INTRODUCTION: Even today, there is still great speculation as to the underlying pathogenesis of inguinal hernia. As a result, it could be extrapolated that the vast majority of repairs are based upon conjecture. Most current repairs are founded upon the principle of "closing the defect" in the anatomy, either by suturing closed under tension, covering with a mesh or obliterating the defect with a plug. Many variants of each method are refined to achieve better clinical outcomes. Yet few, if any, strive to understand a fundamental question: "What has gone wrong with the normal physiological and anatomical mechanisms that prevent abdominal structures protruding through the abdominal wall?" We…
Deep SSI after mesh-mediated groin hernia repair: Management and outcome in an Emergency Surgery Department
2017
Aim. Mesh-mediated groin hernia repair is considered the goldstandard procedure. It has low recurrence rate. Rarely a deep Surgical Site Infection (SSI) is seen when a synthetic prosthesis is used. Case report. We describe a rare case of bilateral deep SSI after mesh- mediated groin hernia repair. Diagnosis was performed through the physical examination and radiological exams. Microbiological samples identified a methicillin-resistant Staphylococcus aureus responsible of the infection. Target therapy was performed and re-operation performed in order to remove the infected prosthesis and to apply a biological one to create the fibrous scaffold. During follow-up time, right side recurrence wa…
Prospective, randomized, single-center trial comparing 3 different 10F plastic stents in malignant mid and distal bile duct strictures.
2003
Abstract Background: The aim of this study was to determine whether patency rates differ with respect to the material, design, and surface texture of 3 different plastic stents. Methods: A total of 120 patients (median age 70.5 years; interquartile range 62-78 years) with malignant mid or distal bile duct strictures, seen between March 1996 and May 1999, were prospectively randomized to receive a 10F polyurethane stent, a Teflon Tannenbaum stent, or a hydrophilic hydromer-coated polyurethane stent. The primary study outcome measure was the interval between stent insertion and the first episode of clogging (or the presence of jaundice at death without stent exchange). All 3 types of stent we…
[Penile Flexiflate® Surgitek prosthesis explant and simultaneous three-component hydraulic Titan® Alpha 1 prosthesis implantation, with double incisi…
2010
Introduction and Objectives We treated a 45 years old patient, suffering from diabetes mellitus since childhood, with retinal, neurovascular and kidney complications. In 1988, for erectile dysfunction (ED) resistant to medical injective treatment, the patient underwent ligation of the dorsal vein of the penis without any result. In 1989 a Flexiflate® hydraulic prosthesis was implanted with resolution of ED. In 2005 the patient underwent simultaneous kidney and pancreas transplant with a trans-laparotomic approach for end stage renal disease and diabetes mellitus. In 2009, because of the Flexiflate® Surgitek malfunction, the patient underwent explantation of the Flexiflate® prosthesis and si…