Search results for "Prosthesis"
showing 10 items of 719 documents
Eight-point compass rose underlay technique in 72 consecutive elderly patients with large incisional hernia
2011
Summary Background Repair of incisional hernia (IH) in the elderly is a challenge for the surgeon. Primary closure is preferable but is not always possible because of high recurrence rates of IH repaired without a prosthesis and/or possible respiratory and cardiovascular complications due to extreme tension of the margins. We report our experience with underlay mesh placement in elderly patients with large IH. Methods A total of 72 patients from January 2003 to December 2009 underwent IH repair involving placement of an intraperitoneal Gore® DualMesh® prosthesis. The prosthesis was first anchored at eight points in a compass rose pattern using a Gore® suture passer and then firmly secured t…
Histopathologic Findings in Early Encapsulated Blebs of Young Patients Treated With the Ahmed Glaucoma Valve
2010
Objective/aim Uncontrolled glaucoma presents a challenge for the ophthalmic surgeon especially in children and juvenile patients. For many patients who have undergone failed surgical procedures before, episcleral implants remain the last choice. Encapsulated blebs forming over antiglaucoma devices present a complication leading to malfunctioning or even failure with reincrease in intraocular pressure. We report our histopathologic findings of such blebs developing around the Ahmed glaucoma valve (AGV) after a short time period in young patients. Materials and methods Nine young patients (2 to 17 y of age) with otherwise uncontrollable glaucoma were treated with AGV (models FP-7 and FP-8, si…
Implantation of a custom intraocular lens with a 30-diopter torus for the correction of high astigmatism after penetrating keratoplasty.
2003
Abstract We present a 62-year-old woman who had implantation of an intraocular lens (IOL) with a torus of 30.0 diopters (D) in an eye after penetrating keratoplasty. The patient presented with cataract and a best corrected visual acuity of 20/400. Penetrating keratoplasty was performed in 1975 because of decompensated keratoconus. With a clear but inferiorly decentered corneal graft, visual acuity was limited because of keratoplasty-related high corneal astigmatism of 22.5@156 that could not be successfully treated with spectacles or contact lenses. A custom toric IOL with –30.0 D of cylindrical power was implanted in the capsular bag via a sclerocorneal tunnel incision. Additionally, a sph…
Endovascular Abdominal Aortic Aneurysm Repair Preserving A Right Crossed Unfused Inferior Ectopic Kidney
2020
Assessment of paradoxical anterior translation in a CR total knee prosthesis coupling dynamic RSA and FE techniques
2021
Purpose: The study aims were to assess the kinematic data, Internal-External (IE) rotation, and Antero-Posterior (AP) translation of the contact points between the femoral condyles and polyethylene insert and to develop a combined dynamic RSA-FE (Radiostereometric – Finite Element) model that gives results congruent with the literature. Methods: A cohort of 15 patients who underwent cemented cruciate-retaining highly congruent mobile-bearing total knee arthroplasty were analyzed during a sit-to-stand motor task. The kinematical data from Dynamic RSA were used as input for a patient-specific FE model to calculate condylar contact points between the femoral component and polyethylene insert. …
Narrow-diameter implants: Are they a predictable treatment option? A literature review
2013
Objective: To evaluate the predictability of narrow-diameter implants as a treatment option in routine clinical practice. A literature review was performed of studies reporting clinical results obtained with these implants. Survival rates, peri-implant bone loss and related complications were evaluated. The working hypothesis was that narrow-diameter implants offer clinical results similar to those obtained with implants of greater diameter. Material and Methods: A Medline-PubMed search covering the period between 2002 and 2012 was carried out. Studies published in English and with a follow-up period of at least 12 months were considered for inclusion. A manual search was also conducted in …
Surface Topographies of Glaucoma Drainage Devices and Their Influence on Human Tenon Fibroblast Adhesion
2010
PURPOSE. This study was performed to investigate the surface topography of different glaucoma drainage devices and to determine the effects of surface roughness on cell adhesion of cultured human tenon fibroblasts.METHODS. The surface topography of four widely used devices (Ahmed FP7 and Ahmed S-2; New World Medical, Inc., Rancho Cucamonga, CA; Baerveldt BG101-350; Advanced Medical Optics, Irvine, CA; and Molteno S1; Molteno Ophthalmic Ltd., Dunedin, New Zealand) was investigated by scanning electron microscopy, and roughness was quantified by white-light confocal microscopy. Cells were grown for 72 hours on the surfaces of implants affixed to standard culture dishes. The cells were labeled…
In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung möglicher Anziehung und Erhitzung der Implantate
2000
PURPOSE In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves during MR imaging at 1.5 T. METHODS 17 prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 degrees, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. RESULTS…
Radiologische Veränderungen nach Implantation zweier unterschiedlicher zementfreier Hüftschaftsysteme
1997
PURPOSE: Of the study was to evaluate radiological alterations of the femoral bone after implantation of two different prostheses. METHODS: 81 patients with 87 hips underwent total hip arthroplasty by using the Zweymuller-stem fixating in the medullary canal, and 175 patients with 182 ABG-stems with a proximally fixating, anatomical design were followed up clinically and radiologically. RESULTS: Adaptive bone remodelling in Zweymuller-stems showed in some patients thickening of the cortex of the femur and proximal bone-stock loss; reactive lines were seen in the proximal areas surrounding the prosthesis. Radiographs of patients with ABG-stems showed these lines in the distal, smooth part of…
Neo-nervegenesis in 3D dynamic responsive implant for inguinal hernia repair. Qualitative study.
2020
Abstract Background Prosthetic repair of inguinal hernias is one of the most performed surgical procedures. Nevertheless, high rates of complications affect the surgical treatment. Implant fixation, poor-quality tissue ingrowth and mesh shrinkage seem to be involved in postoperative complications, discomfort and chronic pain following inguinal hernia repair. To address these issues a multilamellar shaped 3D dynamic responsive prosthesis has been developed. This new implant, positioned fixation-free to obliterate the hernia opening, thanks its inherent dynamic compliance during inguinal movements, has demonstrated to induce an enhanced biological response. The ingrowth of newly formed muscle…