Search results for "Prosthesis"

showing 10 items of 719 documents

Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts

2020

Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…

medicine.medical_specialtyOriginal Scientific Report030204 cardiovascular system & hematologyProsthesis DesignSettore MED/22 - Chirurgia VascolareInfrarenal acute aortic syndromeunibody stent-graftBlood Vessel Prosthesis Implantation03 medical and health sciencesAortic aneurysm0302 clinical medicineintramural hematoma.Blood vessel prosthesismedicine.arterymedicineHumansaortic dissection penetrating aortic ulcercardiovascular diseasesAorta Abdominal030212 general & internal medicineRetrospective StudiesAcute aortic syndromebusiness.industryEndovascular ProceduresAbdominal aortaVascular surgerymedicine.diseaseBlood Vessel ProsthesisSurgeryStenosissurgical procedures operativeTreatment OutcomeCardiothoracic surgeryendovascularStentsSurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryWorld Journal of Surgery
researchProduct

Ergebnisse zementfreier Endoprothesen bei der nichttraumatischen Hüftkopfnekrose

2001

AIM OF THE STUDY The results from 56 patients with osteonecrosis of the femoral head who underwent 66 uncemented total hip replacements were analyzed and compared with current reports in the literature on cemented endoprosthesis. METHODS In the retrospective study in 30 of those cases the Zweymuller and in 25 cases the HA-coated ABG prosthesis were used. In addition the results of 11 patients with a polyethylene Endler cup in combination with a Zweymuller stem are presented. The mean age at surgery was 48 years, the mean follow-up was 5.9 years. Clinical examination, registration of the Merle d'Aubigne score and a radiological examination were performed. RESULTS The clinical results did not…

medicine.medical_specialtyOsteolysismedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentRadiographyRetrospective cohort studyPhysical examinationAvascular necrosismedicine.diseaseProsthesisSurgeryFemoral headmedicine.anatomical_structureOrthopedic surgerymedicineOrthopedics and Sports MedicineSurgerybusinessZeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Jugular pacing lead extraction with laser sheath: a case report.

2010

Over the past 20 years, the number of patients with pacemakers (PM) or implantable cardioverter defibrillators has risen markedly; consequently, an increasing number of lead-removal procedures have become necessary. A 64-year-old woman presenting with an infected device pocket and positive bacterial cultures ( Staphylococcus aureus ) was admitted to our department for lead removal; in 1991, she underwent VVI PM implantation for atrioventricular II degree Mobitz 1 block, and a unipolar lead was introduced via the left jugular vein. The procedure was performed in our Electrophysiology Lab with a cardiac surgeon on standby, using an excimer laser system emitting the energy at the tip of a flex…

medicine.medical_specialtyPacemaker ArtificialProsthesis-Related Infectionslaw.inventionlawPhysiology (medical)Jugular veinlead extracion laser sheatMedicineHumansLead (electronics)Device RemovalEndocarditisbusiness.industryLasersCardiac Pacing ArtificialMiddle AgedStaphylococcal InfectionsLaserSettore MED/11 - Malattie Dell'Apparato CardiovascolareSurgeryCardiothoracic surgeryFluoroscopyFemaleJugular VeinsCardiology and Cardiovascular MedicinebusinessLead extractionEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
researchProduct

Drug eluting and bare metal stents in people with and without diabetes: Collaborative network meta-analysis

2008

Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence fr…

medicine.medical_specialtyPaclitaxelmedicine.medical_treatment030204 cardiovascular system & hematologyCoronary Restenosis03 medical and health scienceschemistry.chemical_compound0302 clinical medicineBlood vessel prosthesisInternal medicinemedicineHumans030212 general & internal medicinecardiovascular diseasesGeneral Environmental ScienceRandomized Controlled Trials as TopicSirolimusbusiness.industryResearchHazard ratioGeneral EngineeringDrug-Eluting StentsGeneral Medicineequipment and supplies3. Good healthSurgeryBlood Vessel ProsthesisProsthesis FailureClinical trialsurgical procedures operativePaclitaxelchemistryDrug-eluting stentMeta-analysisSirolimusGeneral Earth and Planetary SciencesPlatelet aggregation inhibitorStentsbusinessDiabetic AngiopathiesPlatelet Aggregation Inhibitorsmedicine.drug
researchProduct

Biodegradable polymer-coated thin strut sirolimus- -eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population.

2021

Background: The number of patients with diabetes mellitus (DM) presenting with coronary artery disease is increasing and accounts for more than 30% of patients undergoing percutaneous coronary interventions (PCI). The biodegradable polymer drug-eluting stents were developed to improve vascular healing. It was sought herein, to determine 1-year clinical follow-up in patients with DM treated with the thin strut biodegradable polymer-coated sirolimus-eluting stent (BP-SES) versus durable coating everolimus-eluting stent (DP-EES). Methods: Patients were retrospectively analyzed with DM were treated with either a BP-SES (ALEX™, Balton, Poland, n = 670) or a DP-EES (XIENCE™, Abbott, USA, n = 884)…

medicine.medical_specialtyPercutaneousPolymersmedicine.medical_treatmentPopulation030204 cardiovascular system & hematologyProsthesis DesignCoronary artery disease03 medical and health sciences0302 clinical medicinePercutaneous Coronary InterventionInternal medicineAbsorbable ImplantsDiabetes MellitusMedicineHumansMyocardial infarctionEverolimuseducationRetrospective StudiesSirolimuseducation.field_of_studybusiness.industryStentPercutaneous coronary interventionCardiovascular AgentsDrug-Eluting StentsGeneral Medicinemedicine.diseaseInterventional CardiologySurgeryTreatment OutcomeSirolimusConventional PCICardiologyPolandCardiology and Cardiovascular Medicinebusinessmedicine.drugCardiology journal
researchProduct

Patient selection, echocardiographic screening and treatment strategies for interventional tricuspid repair using the edge-to-edge repair technique

2018

Severe tricuspid regurgitation (TR) has long been neglected despite its well-known association with mortality. While surgical mortality rates remain high in isolated tricuspid valve surgery, interventional TR repair is rapidly evolving as an alternative to cardiac surgery in selected patients at high surgical risk. Currently, interventional edge-to-edge repair is the most frequently applied technique for TR repair even though a device has not been developed for this particular indication. Due to the inherent differences in tricuspid and mitral valve anatomy and pathology, percutaneous repair of the tricuspid valve is challenging due to a variety of factors including the complexity and varia…

medicine.medical_specialtyPercutaneousProcedural approach610 Medicine & healthRegurgitation (circulation)030204 cardiovascular system & hematology2705 Cardiology and Cardiovascular Medicine03 medical and health sciences0302 clinical medicineMitral valveHumansMedicinecardiovascular diseases030212 general & internal medicineTRICUSPID VALVE REPAIRHeart Valve Prosthesis ImplantationTricuspid valvebusiness.industryPatient SelectionMitral Valve InsufficiencyTricuspid Valve InsufficiencyCardiac surgery10020 Clinic for Cardiac SurgeryTreatment Outcomemedicine.anatomical_structureEchocardiographycardiovascular systemTreatment strategyTricuspid ValveRadiologyCardiology and Cardiovascular Medicinebusiness
researchProduct

Fully Percutaneous Transaxillary Aortic Valve Replacement With Effective Bailout Plan for Vascular Complications.

2020

medicine.medical_specialtyPercutaneousbusiness.industryAortic Valve StenosisTAVRsubclavian approachtransaxillary TAVRmedicine.diseaseSurgeryTAVITranscatheter Aortic Valve ReplacementPostoperative ComplicationsTreatment Outcometransaxillary TAVIAortic valve replacementRisk FactorsAortic ValveHeart Valve ProsthesismedicineHumansCardiology and Cardiovascular MedicinebusinessBailoutJACC. Cardiovascular interventions
researchProduct

Perkutane Implantation einer endovaskulären Gianturco-Prothese bei V.-subclavia-Verschluß

1989

Observation d'une femme de 72 ans, hemodialysee, avec œdeme croissant du bras portant le shunt. L'obliteration de la veine sous-claviere a ete traitee par fibrinolyse locale, dilatation et prothese de Gianturco

medicine.medical_specialtyPercutaneousbusiness.industrymedicine.medical_treatmentRadiographyProsthesisSurgeryConstrictionBlood vessel prosthesisAngioplastymedicineRadiology Nuclear Medicine and imagingbusinessSubclavian veinRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Quantitative and Qualitative Platelet Derangements in Cardiac Surgery and Extracorporeal Life Support

2021

Thrombocytopenia and impaired platelet function are known as intrinsic drawbacks of cardiac surgery and extracorporeal life supports (ECLS). A number of different factors influence platelet count and function including the inflammatory response to a cardiopulmonary bypass (CPB) or to ECLS, hemodilution, hypothermia, mechanical damage and preoperative treatment with platelet-inhibiting agents. Moreover, although underestimated, heparin-induced thrombocytopenia is still a hiccup in the perioperative management of cardiac surgical and, above all, ECLS patients. Moreover, recent investigations have highlighted how platelet disorders also affect patients undergoing biological prosthesis implanta…

medicine.medical_specialtyPlatelet disorderbiological prosthesisRESPIRATORY-FAILUREProsthesis Implantationlcsh:MedicinethrombocytopeniaReview030204 cardiovascular system & hematologyextracorporeal life supportExtracorporeallaw.invention03 medical and health sciences0302 clinical medicinelawInternal medicineCardiopulmonary bypassmedicinePlatelet030304 developmental biologyplateletUNFRACTIONATED HEPARIN0303 health sciencesCARDIOPULMONARY BYPASSbusiness.industrylcsh:RMEMBRANE-OXYGENATIONACTIVATED PLATELETSGeneral MedicineHypothermiaENDOTHELIAL-CELLSANTIBODY-FORMATIONCardiac surgeryinflammationCORONARY-ARTERY-BYPASSLife supportAORTIC-VALVE-REPLACEMENTCardiologyHEPARIN-INDUCED THROMBOCYTOPENIAmedicine.symptombusinesscardiac surgeryJournal of Clinical Medicine
researchProduct

Comparison of One-Year Outcomes Between the ihtDEStiny BD Stent and the Durable-Polymer Everolimus- and Zotarolimus-Eluting Stents: A Propensity-Scor…

2021

Abstract Objectives We sought to evaluate clinical outcomes in patients treated with the drug-eluting stent ihtDEStiny BD. Background The ihtDEStiny BD stent is a metallic sirolimus eluting stent with a biodegradable polymer with both drug and polymer coating the abluminal surface of the stent and balloon. Methods In this study, the clinical outcomes of a multicenter prospective registry of patients treated with this stent (DEStiny group) were analyzed and compared with those of a control group of patients treated with durable polymer everolimus or zotarolimus eluting stents (CONTROL group) paired by propensity score matching . Primary outcome was the target vessel failure (TVF) at 12 month…

medicine.medical_specialtyPolymersmedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignCoronary artery disease03 medical and health sciences0302 clinical medicinePercutaneous Coronary InterventionAbsorbable ImplantsmedicineClinical endpointHumansZotarolimus030212 general & internal medicineMyocardial infarctionEverolimusPropensity ScoreSirolimusEverolimusbusiness.industryStentDrug-Eluting StentsGeneral Medicinemedicine.diseaseSurgeryTreatment OutcomeDrug-eluting stentPropensity score matchingCardiology and Cardiovascular Medicinebusinessmedicine.drugCardiovascular revascularization medicine : including molecular interventions
researchProduct