Search results for "Pupil"

showing 10 items of 181 documents

Aimer ou non l'école. Ce que déclarent les élèves de l'école élémentaire et pourquoi

2004

This article focuses on the relations of primary school pupils with school.This research work based on a 2,500-strong sample of ten-year olds first analyses the content and polarity of the answers they give to justify why they like school or not. Then we tried to find correlations between their statements and their school or socio-demographic background. Finally the influence of school itself is examined : the class (more than the school environment) and the peer group play a more significant role in pupils' relations to school than methodological issues.

Primary schoolEcole élémentaire[SHS.SOCIO]Humanities and Social Sciences/SociologySchool context[SHS.SOCIO] Humanities and Social Sciences/Sociology[SHS.EDU]Humanities and Social Sciences/Education[SHS.EDU] Humanities and Social Sciences/Education[ SHS.EDU ] Humanities and Social Sciences/EducationPupil[ SHS.SOCIO ] Humanities and Social Sciences/SociologyContexte scolaireRelation école-élève
researchProduct

The effect of fractal contact lenses on peripheral refraction in myopic model eyes.

2014

Purpose: To test multizone contact lenses in model eyes: Fractal Contact Lenses (FCLs), designed to induce myopic peripheral refractive error (PRE). Methods: Zemax ray-tracing software was employed to simulate myopic and accommodation-dependent model eyes fitted with FCLs. PRE, defined in terms of mean sphere M and 90–180 astigmatism J180, was computed at different peripheral positions, ranging from 0 to 35 in steps of 5, and for different pupil diameters (PDs). Simulated visual performance and changes in the PRE were also analyzed for contact lens decentration and model eye accommodation. For comparison purposes, the same simulations were performed with another commercially available conta…

Refractive errorMaterials scienceAstigmatismProsthesis DesignRefraction OcularModels BiologicalPupilMyopia progressionCellular and Molecular NeuroscienceFractalOpticsmedicineMyopiaHumansContact lensesZemaxbusiness.industryModel eyesPeripheral refractionAccommodation Ocularmedicine.diseaseContact Lenses HydrophilicRefractionSensory SystemsContact lensOphthalmologyFractalsFISICA APLICADAVisual FieldsbusinessAccommodationCurrent eye research
researchProduct

Short-Term Changes in Light Distortion in Orthokeratology Subjects

2015

Purpose. Quantifying adaptation to light distortion of subjects undergoing orthokeratology (OK) for myopia during the first month of treatment. Methods. Twenty-nine healthy volunteers (age: 22.34 ± 8.08 years) with mean spherical equivalent refractive error −2.10 ± 0.93D were evaluated at baseline and days 1, 7, 15, and 30 of OK treatment. Light distortion was determined using an experimental prototype. Corneal aberrations were derived from corneal topography for different pupil sizes. Contrast sensitivity function (CSF) was analyzed for frequencies of 1.50, 2.12, 3.00, 4.24, 6.00, 8.49, 12.00, 16.97, and 24.00 cpd under photopic conditions. Results. Average monocular values of all light di…

Refractive errormedicine.medical_specialtyArticle Subjectgenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentLentes de contactolcsh:Medicine01 natural sciencesGeneral Biochemistry Genetics and Molecular BiologyPupil010309 optics03 medical and health sciences0302 clinical medicineDistortionCorneaOphthalmology0103 physical sciencesMedicineContrast (vision)media_commonÓpticaScience & TechnologyGeneral Immunology and Microbiologymedicine.diagnostic_testbusiness.industrylcsh:ROrthokeratologyGeneral Medicinemedicine.diseaseCorneal topographyeye diseasesmedicine.anatomical_structure030221 ophthalmology & optometrysense organsbusinessPhotopic visionResearch ArticleBioMed Research International
researchProduct

Corneal Aberrations, Contrast Sensitivity, and Light Distortion in Orthokeratology Patients: 1-Year Results.

2016

Purpose. To evaluate the corneal higher-order aberrations (HOA), contrast sensitivity function (CSF), and light distortion (LD) in patients undergoing orthokeratology (OK). Methods. Twenty healthy subjects (mean age: 21.40 ± 8 years) with mean spherical equivalent refractive error M = −2.19 ± 0.97 D were evaluated at 1 day, 1 month, and 1 year after starting OK treatment. Monocular LD, photopic monocular CSF, and corneal HOA for 6 mm pupil size were measured. Results. LD showed an increase after the first night (𝑝 0.05). Spherical-like, coma-like, and secondary astigmatism HOA RMS increased significantly (𝑝 ≤ 0.022) from baseline to 1-month visit, remaining unchanged over the follow-up. C…

Refractive errormedicine.medical_specialtyArticle Subjectgenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectSpherical equivalent01 natural sciences010309 optics03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOphthalmology0103 physical sciencesmedicineContrast (vision)In patientmedia_commonScience & Technologybusiness.industryOrthokeratologyPupil sizeHealthy subjectsmedicine.diseaseOphthalmologylcsh:RE1-994030221 ophthalmology & optometryOptometrybusinessPhotopic visionResearch ArticleJournal of ophthalmology
researchProduct

Surgical management of acute angle-closure glaucoma after toric implantable contact lens implantation

2006

A case of pupillary block after implantation of an implantable contact lens (ICL) is reported, and surgical management and prevention are discussed. In a myopic patient, the best corrected visual acuity in the right eye was 20/50 with -15.50 -3.00 x 175. After uneventful implantation of an ICL, painful acute glaucoma developed with an intraocular pressure beyond measurable values. Apparent anterior vaulting of the ICL suggested a sizing problem. In a situation of a mid-wide dilated pupil, immediate explantation of the ICL was performed. Then, using a preoperative iris photography as guidance, an anterior chamber iris-claw toric phakic intraocular lens was implanted. On postoperative examina…

Reoperationmedicine.medical_specialtyIntraocular pressuregenetic structuresContact LensesVisual AcuityPhakic intraocular lensPupilLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIris (anatomy)Device RemovalIntraocular PressurePupillary blockbusiness.industryeye diseasesSensory SystemsSurgeryOphthalmologymedicine.anatomical_structureIris DiseasesAcute angle-closure glaucomaImplantable Contact LensLens (anatomy)Acute DiseaseSurgerysense organsGlaucoma Angle-ClosurebusinessJournal of Cataract and Refractive Surgery
researchProduct

Los nuevos retos de las investigaciones sobre los manuales escolares de historia: entre textos y contextos.

2003

INDICE Presentación Contexto urbano y educación en el estudio de la ciudad de Mérida Aranguren R., Carmen; Antúnez P., Ángel Z.; Rivas A., Marleny; Suárez, Francisco; León , Nury; Lara, Luis E. Los nuevos retos de las investigaciones sobre los manuales escolares de historia: entre textos y contextos Valls Montés, Rafael Las concepciones del docente de Geografía sobre la globalización Santiago Rivera, José Armando La escritura en la formación docente Peña González, Josefina Educación y ciudadanía. Algunas disertaciones Vilera G., Aliria Enseñanza y cultura escolar Pérez Luna, Enrique El estudio y la enseñanza de la historia en escuelas y liceos de Chile en la segunda mitad del siglo XIX Mich…

RevistasRevista de Teoria y Didáctica de las Ciencias SocialesContexteText-booksTeacherAlumnoDidacticsContextPupilDidácticaDocenteDidactiqueContextoLibros de TextoGrupo de Investigación Teoría y Didáctica de las Ciencias SocialesManuelsÉlèveEscuela de EducaciónEnseignementFacultad de Humanidades y Educación
researchProduct

A Performance-Based Test for Assessing Students’ Online Inquiry Competences in Schools

2018

In this paper, we introduce a performance-based test for measuring adolescents’ competences in online inquiry. The test covers four competence dimensions: (1) searching and selecting relevant sources, (2) identifying the main ideas presented in the sources, (3) evaluating the credibility of the sources, and (4) synthesizing information across the sources. We implement a technological solution called NEURONE to carry out this routine. The scoring of the test data is demonstrated by presenting preliminary results of a case study. Finally, we discuss the strengths and limitations of the test.

SchoolsComputer scienceInformation literacy05 social sciences050301 educationPupilsMedia- ja viestintätieteet - Media and communicationsCredibilityMathematics educationPerformance-based testsOnline inquiry competencesInformation literacies0509 other social sciences050904 information & library sciences0503 educationCompetence (human resources)Test data
researchProduct

Assessment of student engagement among junior high school students and associations with self-esteem, burnout, and academic achievement

2016

Journal for educational research online 8 (2016) 2, S. 136-157

SelbstwertgefühlLower secondary educationAffektives LernenUmfrageErziehung Schul- und BildungswesenErhebungsinstrumenteducationMail surveyscognitive engagementLower secondaryVerhalten370 Erziehung Schul- und BildungswesenSchool successCognitive learningSuccess at schoolEducationSecondary education lower levelddc:370Teacher burnoutEmpirische BildungsforschungReliabilitätFinlandSekundarstufe Istudent-engagement-instrumentEngagementSchülerleistungbehavioral engagementEmpirische UntersuchungBurnout-SyndromPupilKognitives LernenPädagogische PsychologieReliabilityValiditätPupilsEmpirical studyFinnlandStudent achievementaffective engagementLower level secondary educationSchülerInvolvement370 EducationPsychometriePsychometrySchulerfolgPupil achievement
researchProduct

Bright Pupil Detection in an Embedded, Real-Time Drowsiness Monitoring System

2010

Driver’s drowsiness is stated as an important cause of road and highway accidents. Therefore, the development of a system for monitoring the driver’s level of fatigue is desirable in order to prevent accidents. The paper presents the design and the implementation of a system able to find and evidence the drowsiness level of a driver in an ordinary motor vehicle, in order to prevent car accidents. The system, made up of a car installed infrared video camera connected to the Celoxica RC203E FPGA based board, is able to perform a real time video stream processing. The system exploits the “bright pupil” phenomenon produced by the retina, that reflects the 90% of the incident light when a radiat…

Settore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniRetinaComputer sciencebusiness.industrymedia_common.quotation_subjectFrame (networking)ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONProcess (computing)Video cameraMonitoring systemPupillaw.inventionStream processingReal-time Systems Drowsiness Monitoringmedicine.anatomical_structurelawmedicineComputer visionArtificial intelligenceFunction (engineering)businessmedia_common2010 24th IEEE International Conference on Advanced Information Networking and Applications
researchProduct

dilatazione pupillare farmacologica come test predittivo del rischio di IFIS.

2013

Settore MED/30 - Malattie Apparato Visivofloppy iris syndromepredittività rischio IFIS dilatazione pupillare
researchProduct