Search results for "RADIATION"
showing 10 items of 5298 documents
Long-term radiation exposure in patients undergoing EVAR: Reflecting clinical day-to-day practice to assess realistic radiation burden.
2018
Endovascular repair of aortic aneurysms (EVAR) has become an established treatment option currently applied in an increasing numbers of patients with aortic aneurysms. Advantages include reduced surgical trauma, procedural time, intensive care unit and hospital lengths of stay, blood loss as well as morbidity and mortality.The optimal imaging modalities in EVAR follow-up as well as the appropriate intervals between these follow-ups remain subject of controversial discussion. Objective of this study was the evaluation of the realistic radiation exposure and risk estimate postop EVAR treatment.Of the follow-ups required according to the surveillance schedule during the first year post-EVAR, o…
Fatty replacement of bone marrow after radiation therapy for Hodgkin disease: Quantification with chemical shift imaging
1993
The authors studied the long-term fatty replacement of bone marrow in 23 patients who had received radiation therapy for Hodgkin disease, with T1-weighted magnetic resonance imaging and quantitative chemical shift imaging. T1-weighted images revealed a mostly homogeneous high-signal-intensity pattern, in contrast to the hypointense pattern of nonirradiated marrow. The degree of fatty replacement was objectively assessed with chemical shift imaging, comparing patients to age-matched healthy volunteers. The authors found an increase in relative fat signal of 37% in the thoracic spine and 34% in the lumbar spine. The relative fat signal of nonirradiated pelvic and femoral marrow was decreased …
The fate of patients with locally advanced bladder cancer treated conservatively with neoadjuvant chemotherapy, extensive transurethral resection and…
1998
Purpose: We assess the results of bladder preservation for infiltrating bladder cancer. The potential for neoadjuvant chemotherapy followed by extensive transurethral resection and radiotherapy was evaluated in 40 patients with T2-T4a G2-G3 bladder carcinoma. Materials and Methods: From 1983 to 1995, 40 patients with bladder cancer underwent bladder sparing treatment, consisting of neoadjuvant chemotherapy, extensive transurethral resection and radiotherapy. Most patients had T3G3 cancer. A deep transurethral resection biopsy was performed before and after chemotherapy, and an extensive transurethral resection was repeated at the end of radiotherapy. Of the patients 30 received cisplatin an…
Computerized tomography: an unreliable method for accurate staging of bladder tumors in patients who are candidates for radical cystectomy.
1989
A total of 164 patients with bladder tumors underwent preoperative staging by computerized tomography. All patients were previously untreated, or had undergone only transurethral biopsy or resection of the tumor before computerized tomography. The post-cystectomy histological stage was compared to the preoperative computerized tomography stage. Computerized tomography accuracy according to the tumor, nodes and metastasis classification was only 32.3%, whereas overstaging was found in 39.6% and understaging in 28.1% of the cases. In untouched tumors or after transurethral resection computerized tomography accuracy demonstrated no significant difference. Only 2 of 19 true positive lymph nodes…
Stereotactic fractionated irradiation of optic nerve sheath meningioma: a new treatment alternative
2002
Background: Primary optic nerve sheath meningioma (ONSM) is a rare but almost invariably blinding tumour when its natural history is observed in a “wait and see” strategy. Surgery has hitherto only been advocated in case of progressive disease involving intracranial structures, as it leads to iatrogenic blindness in the overwhelming majority of cases. Therefore, treatment options bearing lesser risk of functional deterioration are highly desirable, both in cases of intracranial involvement as well as during earlier phases of the disease which are currently generally left untreated. The authors report the outcome of the largest series of patients to date treated by stereotactic fractionated …
Covariation of spectral and nonlinear EEG measures with alpha biofeedback.
2002
Item does not contain fulltext This study investigated how different spectral and nonlinear EEG measures covaried with alpha power during auditory alpha biofeedback training, performed by 13 healthy subjects. We found a significant positive correlation of alpha power with the largest Lyapunov-exponent, pointing to an increased dynamical instability of the EEG accompanying alpha enhancement. Alpha power amplification, moreover, was significantly correlated with a decrease of spectral entropy within the alpha range. This outcome reflects a sharpening of the alpha peak during biofeedback training. The fact that the sharpening effect clearly preceded the increase of alpha amplitude could be exp…
Prophylaxis of radiogenic sialadenitis and mucositis by coumarin/troxerutine in patients with head and neck cancer--a prospective,randomized, placebo…
2001
To study the efficacy of coumarin/troxerutine for the protection of salivary glands and mucosa during irradiation. Design: Prospective, randomized, placebo-controlled, double-blind trial. Setting: University hospital, Germany. Patients: 48 patients who had radiotherapy to the head and neck. Main outcome measures: Salivary gland scintigraphy and acute side-effects of radiotherapy (Radiation Therapy Oncology Group (RTOG) score). Results: 23 patients (11 experimental, 12 placebo) completed the study. The global efficacy measure combining scintigraphy and RTOG score favoured the experimental arm (P= 0.07). The RTOG score showed significantly fewer acute side-effects of radiation in the experime…
Hippocampal dose during Linac-based stereotactic radiotherapy for brain metastases: An observational study
2017
Abstract Introduction Aim of the present study is to evaluate homolateral and contralateral hippocampus (H-H, C-H, respectively) dose during Fractionated Stereotactic Radiotherapy (FSRT) or Radiosurgery (SRS) for brain metastases (BM). Materials & methods Patients with BM 3 months, were considered for SRS/FSRT (total dose 15–30 Gy, 1–5 fractions). For each BM, a Flattening Filter Free (FFF) Volumetric Modulated Arc Therapy (VMAT) plan was generated with one or two arcs. Hippocampi were not considered during optimizations phase and were contoured and evaluated retrospectively in terms of dose: the Dmedian, Dmean, D0.1cc and the V1Gy, V2Gy, V5Gy and V10Gy were analyzed. Results From April 2…
Spectral transmission of the pig lens: Effect of ultraviolet A+B radiation
2014
Summary Objective To determine the spectral transmission curve of the crystalline lens of the pig. To analyse how this curve changes when the crystalline lens is irradiated with ultraviolet A + B radiation similar to that of the sun. To compare these results with literature data from the human crystalline lens. Procedures We used crystalline lenses of the common pig from a slaughterhouse, i.e. genetically similar pigs, fed with the same diet, and slaughtered at six months old. Spectral transmission was measured with a Perkin-Elmer Lambda 35 UV/VIS spectrometer. The lenses were irradiated using an Asahi Spectra Lax-C100 ultraviolet source, which made it possible to select the spectral emissi…
Light scattering in artificial fog and simulated with light scattering filter.
2009
Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a…