Search results for "RAYS"
showing 10 items of 1136 documents
FUZZY RISK ANALYSIS OF A MODERN γ-RAY INDUSTRIAL IRRADIATOR
2011
Fuzzy fault tree analyses were used to investigate accident scenarios that involve radiological exposure to operators working in industrial γ-ray irradiation facilities. The HEART method, a first generation human reliability analysis method, was used to evaluate the probability of adverse human error in these analyses. This technique was modified on the basis of fuzzy set theory to more directly take into account the uncertainties in the error-promoting factors on which the methodology is based. Moreover, with regard to some identified accident scenarios, fuzzy radiological exposure risk, expressed in terms of potential annual death, was evaluated. The calculated fuzzy risks for the examine…
Can immunohistochemical biomarkers distinguish epithelial dysplasia degrees in actinic cheilitis? A systematic review and meta-analysis
2019
Background Actinic cheilitis (AC) is a poten-tially malignant disorder of the lip, characterized by epithelial and connective tissue alterations caused by chronic exposure to ultraviolet radiation. In the past decades, diverse studies have been conducted in lip carcinogenesis and many biomarkers have been identified in lip lesions, yet there is no scientific evidence that determines its usefulness in the clinical setting or in histopatho-logical routine. Therefore, we conducted the first systematic review in this field to summarize the results of published studies on immunohistochemical bi-omarkers in lip carcinogenesis, to evaluate if there is a marker than can distin-guish the different h…
Kernel image similarity criterion
2011
This paper presents a family of metrics for assessing image similarity. The methods use the Hilbert-Schmidt Independence Criterion (HSIC) to estimate nonlinear statistical dependence between multidimensional images. The proposed methods have very good theoretical and practical properties. We illustrate the performance in evaluating the quality of natural photographic images, hyperspectral images under different noise levels, in synthetic multiresolution problems, and real pansharpening products.
Nanoseconds Timing System Based on IEEE 1588 FPGA Implementation
2019
Clock synchronization procedures are mandatory in most physical experiments where event fragments are readout by spatially dislocated sensors and must be glued together to reconstruct key parameters (e.g. energy, interaction vertex etc.) of the process under investigation. These distributed data readout topologies rely on an accurate time information available at the frontend, where raw data are acquired and tagged with a precise timestamp prior to data buffering and central data collecting. This makes the network complexity and latency, between frontend and backend electronics, negligible within upper bounds imposed by the frontend data buffer capability. The proposed research work describ…
Analysis of DNA single-strand breaks in human venous blood: a technique which does not require isolation of white blood cells.
1997
For DNA strand break analysis in human white blood cells, usually metrizoate-Ficoll centrifugation is used to isolate mononuclear cells. This procedure is time-consuming and requires at least 20 ml of blood per sample. Therefore, we developed a technique which does not require isolation of white blood cells prior to DNA strand break analysis by alkaline elution (direct method). The sensitivity of this new technique was compared to that of the standard method, which includes isolation of mononuclear blood cells. A statistically significant increase in sensitivity was observed using the direct method. After in vitro gamma-irradiation of venous blood, an increase in the elusion rate of 7.7 × 1…
Novel mechanism for the radiation-induced bystander effect: nitric oxide and ethylene determine the response in sponge cells.
2006
Until now the bystander effect had only been described in vertebrates. In the present study the existence of this effect has been demonstrated for the phylogenetically oldest metazoan phylum, the Porifera. We used the demosponge Suberites domuncula for the experiments in the two-chamber-system. The lower dish contained irradiated "donor" cells (single cells) and the upper dish the primmorphs ("recipient" primmorphs). The "donor" cells were treated with UV-B light (40 mJ/cm2) and 100 microM hydrogen peroxide (H2O2), factors that exist also in the natural marine aquatic environment of sponges; these factors caused a high level of DNA strand breaks followed by a reduced viability of the cells.…
Evanescent wave-initiated photopolymerisation as a new way to create monolithic open-tubular capillary columns: use as enzymatic microreactor for on-…
2010
Evanescent wave-initiated photopolymerisation in an optically wave guiding PTFE-coated fused silica capillary using light-emitting diode as a light source, is established here as a way to fabricate monolithic porous layer open-tubular capillary columns with a potential in capillary separation methods; application of the obtained open-tubular columns as enzymatic microreactors for on-line protein digestion is demonstrated.
Light-component spectrum of the primary cosmic rays in the multi-TeV region measured by the ARGO-YBJ experiment
2012
The ARGO-YBJ experiment detects extensive air showers in a wide energy range by means of a full-coverage detector which is in stable data taking in its full configuration since November 2007 at the YBJ International Cosmic Ray Observatory (4300 m a.s.l., Tibet, People's Republic of China). In this paper the measurement of the light-component spectrum of primary cosmic rays in the energy region $(5\textdiv{}200)\text{ }\text{ }\mathrm{TeV}$ is reported. The method exploited to analyze the experimental data is based on a Bayesian procedure. The measured intensities of the light component are consistent with the recent CREAM results and higher than that obtained adding the proton and helium sp…
Measurement of the cosmic ray energy spectrum using hybrid events of the Pierre Auger Observatory
2012
The energy spectrum of ultra-high energy cosmic rays above 10$^{18}$ eV is measured using the hybrid events collected by the Pierre Auger Observatory between November 2005 and September 2010. The large exposure of the Observatory allows the measurement of the main features of the energy spectrum with high statistics. Full Monte Carlo simulations of the extensive air showers (based on the CORSIKA code) and of the hybrid detector response are adopted here as an independent cross check of the standard analysis (Phys. Lett. B 685, 239 (2010)). The dependence on mass composition and other systematic uncertainties are discussed in detail and, in the full Monte Carlo approach, a region of confiden…
Search for ultrarelativistic magnetic monopoles with the Pierre Auger Observatory
2016
We present a search for ultra-relativistic magnetic monopoles with the Pierre Auger Observatory. Such particles, possibly a relic of phase transitions in the early universe, would deposit a large amount of energy along their path through the atmosphere, comparable to that of ultrahigh-energy cosmic rays (UHECRs). The air shower profile of a magnetic monopole can be effectively distinguished by the fluorescence detector from that of standard UHECRs. No candidate was found in the data collected between 2004 and 2012, with an expected background of less than 0.1 event from UHECRs. The corresponding 90% confidence level (C.L.) upper limits on the flux of ultra-relativistic magnetic monopoles ra…