Search results for "RDW"
showing 10 items of 1401 documents
Experimental study of low-voltage surge protection device response in realistic systems
2008
Experimental results on low-voltage surge protection under fast pulses in realistic wiring systems are presented. A fast voltage pulse generator is designed to provide fast voltage pulses with short steep fronts. The effective residual voltage of protected equipment is then investigated and compared with simulation results.
Radio measurements on a customized software defined radio module: A case study of energy detection spectrum sensing
2017
In this paper, we developed a software defined radio (SDR) system for implementing energy detection spectrum sensing. The SDR module can be used for a wide range of applications. The use of the SDR module is motivated by its high interoperability, availability for relatively cheaper prices and being software independent. Energy detection for cognitive radios is chosen for its simplicity and popularity. However, it is chosen as a representative for a very wide range of measurements and algorithms that can be implemented in the SDR. We have used probabilities of detection and false alarm with the receiver operating characteristics (ROC) curves as performance metrics for the implemented energy…
New solutions for prefabricated secondary substations in the view of sustainability
2016
The secondary substations will assume an important role as “smart nodes” of the smart grid. So in few years there will be a widespread dissemination on the territory of this apparatus. Consequently, great care have to be taken not only on safety issues, but also on the constructive methodology, in order to determine low environmental impact and decommissioning cost. This paper focuses on innovative solutions for the realization of prefabricated secondary substations, in the direction of sustainability. Innovative layout and enclosure topologies have been here taken into account. In particular, by considering that the substation concrete box is, at the same time, uneconomical and with strong…
Charging Electric Vehicles Using Opportunistic Stopovers
2017
The diffusion of electric vehicles asks for efficient energy replenishment, which requires geographical and temporal coordination of shared charging resources. We introduce a novel charging methodology that exploits users’ opportunistic mobility. This paper focuses on vehicle stopovers detecting potential charg- ing opportunities. Our mobility-assisted methodology protects users privacy and permits a hybrid centralized/distributed ap- proach avoiding clashes with other potential users. A preliminary analysis on our charging system, obtained with mobility data from the field, shows that among the available charging stations, some are more relevant and have a key role in serving electric vehi…
Using the Microcontroller and the PLC in a RPP Robot Control
2012
This paper presents some aspects regarding the possibility of combining microcontroller and programmable logic controller (PLC) for robot control. The RPP robot is designed and manufactured within the Faculty of Engineering from “Lucian Blaga” University of Sibiu, as a patent: BRAŢ TELESCOPIC, Nr. 112418 B1, Int.CI.6 B 25 J 18/02, from 17.02.1997. Classical systems for programming and control of industrial robot are based on numerical control equipment, developed around a PC. Programmable Logic Controllers (PLC) haves proven to be viable alternatives to driving machine tools, industrial systems and Robots. Microcontrollers as computers offer advantage due to programmable inputs and outputs …
An optimization location scheme for electric charging stations
2013
International audience; Due to environmental issues, electric mobility is one of the mobility alternatives that are receiving a huge attention nowadays. In fact, in the last few years electric vehicles have entered the world's car market. This revolutionary technology requires a fast deployment of electric charging stations since the key issue in this system is recharging the batteries. In this work, we propose an optimized algorithm to locate electric-vehicles charging stations. Different factors and limitations are considered and a real case study is given as an application. We first determine the appropriate strict constraints and cost of charging stations' location; and then we propose …
Control of solid-state fault current limiter for DG-integrated distribution systems
2017
Fault current limier (FCL) is a device that limits the system current under fault conditions without disconnecting the system and affecting the power system protection components such as circuit breakers. Many types of FCLs have been proposed to limit the magnitude of the fault current. Solid-state fault current limiters (SSFCLs) can limit the peak value of the fault current by applying several methods, such as controlling the system impedance or controlling the voltage that appears across the fault. In this paper, a new control scheme for the SSFCL circuit is presented. The control method is based on controlling the duty cycle of solid state switches to control the rms value of the system …
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
Exploring FPGA‐Based Lock‐In Techniques for Brain Monitoring Applications
2017
Functional near‐infrared spectroscopy (fNIRS) systems for e‐health applications usually suffer from poor signal detection, mainly due to a low end‐to‐end signal‐to‐noise ratio of the electronics chain. Lock‐in amplifiers (LIA) historically represent a powerful technique helping to improve performance in such circumstances. In this work a digital LIA system, based on a Zynq® field programmable gate array (FPGA) has been designed and implemented, in an attempt to explore if this technique might improve fNIRS system performance. More broadly, FPGA‐based solution flexibility has been investigated, with particular emphasis applied to digital filter parameters, needed in the digital LIA, and its …
A Technique for Power Supply Harmonic Impedance Estimation Using a Controlled Voltage Disturbance
2002
A method for power system impedance estimation is presented. The method employs a power converter to inject a voltage transient onto the supply system. As the technique employs controlled power electronic devices it may be used as a stand alone piece of a portable measurement equipment, or it may be embedded into the functions of an active shunt filter for improved harmonic control. The impedance is estimated through correlation of the measured voltage and current transients. Simulations and experimental results demonstrate the measurement technique is highly accurate and effective.