Search results for "REAGENT"
showing 10 items of 699 documents
Effectiveness of microwave based digestion procedures for the demineralization of human milk and infant formulas prior to fluorometric determination …
1996
The use of two types of microwave oven, one domestic (A) and the other specially designed for laboratory (B) for microwave-based digestion, to destroy the organic matter in milk and infant formulas prior to fluorometric determination of selenium is studied in order to check their applicability and reliability. In both systems the best results were obtained using the acid mixture HNO3—H2O2, and additional treatment with perchloric acid (60%) in a Thermoblock. The application of two different microwave-based digestion procedures to infant formulas was free of interferences. In the case of human milk, it was necessary to use the standard addition method. Values obtained for detection and quant…
Chromo-Fluorogenic Detection of Nerve-Agent Mimics Using Triggered Cyclization Reactions in Push-Pull Dyes
2010
A family of azo and stilbene derivatives (1-9) are synthesized, and their chromo-fluorogenic behavior in the presence of nerve-agent simulants, diethylchlorophosphate (DCP), diisopropylfluorophosphate (DFP), and diethylcyanophosphate (DCNP) in acetonitrile and mixed solution of water/acetonitrile (3:1 v/v) buffered at pH 5.6 with MES, is investigated. The prepared compounds contain 2-(2-N,N-dimethylaminophenyl)ethanol or 2-[(2-N,N-dimethylamino)phenoxy]ethanol reactive groups, which are part of the conjugated pi-system of the dyes and are able to give acylation reactions with phosphonate substrates followed by a rapid intramolecular N-alkylation. The nerve-agent mimic-triggered cyclization …
Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextra…
2017
Abstract An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid–liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography–ultraviolet/visible (LC–UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sampl…
Characterization of particle morphology of biochanin A molecularly imprinted polymers and their properties as a potential sorbent for solid-phase ext…
2014
Abstract Molecularly imprinted polymers (MIPs) with biochanin A as a template were obtained using a bulk polymerization with non-covalent imprinting approach. The polymers were prepared in acetonitrile as porogen, using ethylene glycol dimethacrylate (EDMA) as cross-linking agent. The synthesis, with an application of 1′,1′-azobis(cyclohexanecarbonitrile) (ACHN) as an initiator, has been performed thermally. During the synthesis process the effect of different functional monomers such as methacrylic acid (MAA), acrylamide (AA) and 4-vinylpyridine (4-VP) was investigated. The application of nitrogen sorption porosimetry, scanning electron microscopy (SEM), and Fourier transform infrared spec…
Ferrocenylbis(ylene) phosphoranes
1997
The ferrocenylbis(methylene)phosphorane Fc-P(=CTms 2 ) 2 ( 1 ) (Fc = −C 5 H 4 FeC 5 H 5 ) can be synthesized starting from ferrocenyldichlorophosphane FcPCl 2 or ferrocenyldilithiophosphane FcPLl 2 . The X-ray structure of ( 1 ) shows some unusual structural features, which indicate considerable electronic interaction of the ferrocenyl group and the σ 3 λ 5 -phosphorane unit. As a consequence of this interaction, the rotational barrier of the methylene bonds is extraordinary low. Therefore, in contrast to other bis(methylene)phosphoranes, the endo - and exo -Tms groups are indistinguishable on the NMR time scale even at −100°C. The analogous ferrocenylbis(imino)phosphorane Fc-P(=NTms) 2 ( 9…
Immunochemical faecal occult blood tests are superior to guaiac-based tests for the detection of colorectal neoplasms
2008
The aim of this study was to compare the performance of a guaiac-based faecal occult blood test (G-FOBT) with that of an immunochemical faecal occult blood test (I-FOBT). A total of 17,215 average risk individuals aged 50 to 74 enrolled in a population-based organised screening programme and performed a 3-day G-FOBT and a 2-day I-FOBT simultaneously. Among participants, 3.1% were found positive for the G-FOBT and 6.9% for the I-FOBT (p<10(-4)). Among the 1205 participants who tested positive and underwent a colonoscopy, the number of detected cancers and advanced adenomas was respectively 2.6 times higher and 3.5 times higher with the I-FOBT than with the G-FOBT. The positive predictive val…
Interpretive search of optimal isocratic and gradient separations in micellar liquid chromatography in extended organic solvent domains
2020
Abstract Micellar liquid chromatography (MLC) is a reversed-phase mode with mobile phases containing an organic solvent and a micellised surfactant. Most procedures developed in MLC are implemented in the isocratic mode, since the general elution problem in chromatography is less troublesome. However, gradient elution may be still useful in MLC to analyse mixtures of compounds within a wide range of polarities, in shorter times. MLC using gradients is attractive to determine by direct injection moderate to low polar compounds in physiological samples. In these analyses, the use of initial micellar conditions (isocratic or gradient) with a fixed amount of surfactant above the critical micell…
Confined But-2-ene catalytic isomerization inside H-ZSM-5 models: A DFT study
2015
The isomerization of cis-but-2-ene to trans-but-2-ene within a 22T H-ZSM-5 zeolite model, also in the presence of two adsorbed Pd atoms, has been studied by DFT calculations. The results obtained allow us to state that the cis/trans but-2-ene isomerization can easily proceed inside unsupported zeolite cavities. In this case, differently than in the gas phase reaction, the trans-but-2-ene is less stable than the cis-but-2-ene, when adsorbed on the zeolite inner surface. Excluding the adsorption-desorption steps, the isomerization process involves two intermediates and three transition states, whose energy content is always very low with respect to that of reagents and intermediate species. T…
Biocompatibility of various collagen membranes in cultures of human PDL fibroblasts and human osteoblast-like cells
2004
The aim of the present study was to evaluate the biocompatibility of differently cross-linked collagen membranes in cultures of human PDL fibroblasts and human osteoblast-like cells. Four collagen membranes [BioGide (BG), BioMend (BM), Ossix (OS) and TutoDent (TD)] were tested. Cells plated on culture dishes (CD) served as positive controls. Six specimens of each membrane were incubated with (1) human PDL fibroblasts [2 x 10(4) cells] (n=24), and (2) human osteoblast-like cells (SaOs-2) [2 x 10(4) cells] (n=24) under standardized conditions. After 7 days, adherent cells were stained with hematoxylin and counted using a reflected light microscope and the cell density per square millimeter wa…
New spectrophotometric procedure for determining cefotaxime based on derivatization with 1,2-naphthoquinone-4-sulphonate into solid-phase extraction …
1998
Cefotaxime was derivatised with 1,2-naphthoquinone-4-sulphonate (NQS), extracted into solid-phase cartridges (C18) and detected using a UV-visible detection system. Optimum conditions for this new procedure were: hydrogencarbonate-carbonate buffer, pH 10.5, 5-min reaction time at 25 degrees C and an NQS concentration of 7.1x10(-3) mol l(-1). The accuracy and the precision of the liquid-solid procedure were tested. The procedure was used to measure cefotaxime in pharmaceutical and urine samples. The results obtained were contrasted with those reported for a HPLC method for urine samples. The generalized H-point standard additions method was used to measure cefotaxime in urine samples.