Search results for "RESTOR"
showing 10 items of 670 documents
Long-term recovery of stream habitat structure and benthic invertebrate communities from in-stream restoration
2002
Headwater streams channelized for water transport of timber in Finland are being restored to their pre-channelization state. The primary motivation is the enhancement of sport fisheries, but restoration probably has profound impacts also on other stream organisms. We assessed how such ‘‘single-goal’’ restorations affect benthic macroinvertebrate communities. We revisited the streams sampled by Laasonen et al. [Aquatic Conservation: Marine and Freshwater Ecosystems 8 (1998)] in the early 1990s when the streams had been recently restored. In 1997, the recovery period of these streams ranged from 4 to 8 years. Habitat structure among the stream types represented a distinct recovery gradient, w…
Reducing effects of aberration in 3D fluorescence imaging using wavefront coding with a radially symmetric phase mask.
2016
In this work, a wavefront encoded (WFE) imaging system built using a squared cubic phase mask, designed to reduce the sensitivity of the imaging system to spherical aberration, is investigated. The proposed system allows the use of a space-invariant image restoration algorithm, which uses a single PSF, to restore intensity distribution in images suffering aberration, such as sample–induced aberration in thick tissue. This provides a computational advantage over depth-variant image restoration algorithms developed previously to address this aberration. Simulated PSFs of the proposed system are shown to change up to 25% compared to the 0 µm depth PSF (quantified by the structural similarity i…
Experimental validation of a customized phase mask designed to enable efficient computational optical sectioning microscopy through wavefront encodin…
2017
In this paper, wavefront-encoded (WFE) computational optical sectioning microscopy (COSM) using a fabricated square cubic (SQUBIC) phase mask, designed to render the system less sensitive to depth-induced aberration, is investigated. The WFE-COSM system is characterized by a point spread function (PSF) that does not vary as rapidly with imaging depth compared to the conventional system. Thus, in WFE-COSM, image restoration from large volumes can be achieved using computationally efficient space-invariant (SI) algorithms, thereby avoiding the use of depth-variant algorithms. The fabricated SQUBIC phase mask was first evaluated and found to have a 75% fidelity compared to the theoretical desi…
Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses. A systematic revie…
2018
OBJECTIVES To evaluate the implant failure, marginal bone loss (MBL), and other biological or technical complications of restorations supported by tilted and straight implants after at least 3 years in function. METHODS Electronic and manual searches were performed in MEDLINE, Embase, Web of Science, and OpenGrey to identify clinical studies published up to December 2017. After duplicate study selection and data extraction, the risk of bias was assessed with the ROBINS-I tool. Random-effects meta-analyses of relative risks (RRs) or mean differences (MD) and their 95% confidence intervals (CIs) were performed, followed by subgroup/sensitivity analyses and application of the GRADE approach. R…
Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis
2019
Background: The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. Materials and methods: This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health …
Deep controls on Foreland Basin System evolution along the Sicily Thrust Belt
2014
The palinspastic restoration of the Sicilian crustal geological cross section (Catalano et al., 2013) points out two subsequent main thrust (MT1 and MT2) active during the Neogene tectonic evolution as well as the decrease of slip and shortening rate estimated for MT2 with respect to MT1 early main thrust. During orogenic building, syn-tectonic deposits are accumulated inside wedge-top-basin that grow on top of thrust sheets. Sedimentary and stratigraphic features of wedge-top basin change trough time following fold and thrust belt evolution. Neogene-Quaternary syn- tectonic successions (terrigenous, evaporitic, hemipelagic and shallow water deposits) extensively crop-out, in more or less w…
Color stability of Bulk-Fill composite restorations
2020
Made available in DSpace on 2022-04-28T19:29:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2020-11-01 Background: The color stability of the composite resin is an important property that influences its clinical longevity, which remains an inherent challenge to the material. Thus, the purpose of this study was to evaluate the color stability of bulk-fill resins when exposed to dye. Material and Methods: Cavities were prepared in 80 bovine incisors, which were randomly assigned into 4 groups (n = 20) according with the resin composite used: P60 (Control Group - Filtek P60, 3M/ESPE), FP (Filtek Bulk-Fill Posterior, 3M/ESPE), SDR (SDR, Dentsply) and FF (Filtek Bulk Fill Flow, 3M/ESPE). A…
Vertical root fracture in endodontically treated teeth: A review of 25 cases
2001
Abstract Objective: We sought to examine the clinical conditions under which 25 endodontically treated teeth underwent vertical root fracture (VRF) and to relate this condition to the time elapsed from endodontic treatment to fracture. Study Design: This was a retrospective study in which we reviewed 25 case histories of patients with postendodontic VRF and studied the effect of various pretreatment and posttreatment factors as they related to VRF. Results And Conclusions: The mean time to VRF was 54 months; this was not significantly influenced by the presence or absence of prior restoration or by the presence or absence of a crown fitting. The use of a prefabricated, cylindrical, cemented…
Image registration for quality assessment of projection displays
2014
International audience; In the full reference metric based image quality assessment of projection displays, it is critical to achieve accurate and fully automatic image registration between the captured projection and its reference image in order to establish a subpixel level mapping. The preservation of geometrical order as well as the intensity and chromaticity relationships between two consecutive pixels must be maximized. The existing camera based image registration methods do not meet this requirement well. In this paper, we propose a markerless and view independent method to use an un-calibrated camera to perform the task. The proposed method including three main components: feature e…
AN APPROACH TO CORRECTING IMAGE DISTORTION BY SELF CALIBRATION STEREOSCOPIC SCENE FROM MULTIPLE VIEWS
2012
International audience; An important step in the analysis and interpretation of video scenes for recognizing scenario is the aberration corrections introduced during the image acquisition in order to provide and correct real image data. This paper presents an approach on distortion correction based on stereoscopic self calibration from images sequences by using a multi-camera system of vision (network cameras). This approach for correcting image distortion brings an elegant and robust technique with good accuracy. Without any knowledge of shooting conditions, the camera's parameters will be estimated. For this, the image key points of interest are extracted from different overlapping views …