Search results for "Radiation"
showing 10 items of 5298 documents
The wolf in sheep’s clothing: microtomographic aspects of clinically incipient radiation-related caries
2015
Background: Radiation-related caries (RRC) can cause rapid progression, with a high potential for dental destruction affecting mainly cervical and incisal areas. Unlike the injuries that occur in the conventional caries, incipient RRC present in unusual surfaces have difficult diagnosis and classification stages of cavitation. Material and Methods: Evaluate the radiographic patterns of demineralization of RRC by using micro-CT. Ten teeth with incipient RRC and 10 teeth with incipient conventional caries (control group) matched by anatomic teeth group and caries affected surfaces were evaluated by X-ray microtomography (micro-CT) Skyscan 1174V2 (50Kv, 1.3 megapixel, Kontich, Belgium). Teeth …
The nature of radiohaloes in biotite: Experimental studies and modeling
2001
Several micro-techniques (confocal laser-Raman microprobe, optical absorption micro-spectroscopy, high-resolution transmission electron microscopy, electron microprobe analysis) were employed in the detailed characterization of radiohaloes in biotites from two Variscan rocks from Germany. The studied biotites are intermediate members of the phlogopite-annite series with Mg/Fe 2+ ratios in the range 1.6–1.0. Radiohaloes in biotite resulted from the impact of 4 He cores (α-particles) emitted from actinide-bearing inclusions. Monte Carlo simulations yielded α ( 238 U, 235 U, and 232 Th series) penetration ranges in biotite between 12.5 and 37.3 μm, which are in reasonable agreement with the ob…
Management of painful bone metastases.
2007
PURPOSE OF REVIEW: This review examines recent data on the pathophysiology and mechanisms of bone pain; it highlights the use of multiple and interdisciplinary treatments rather than sole use of traditional analgesics. RECENT FINDINGS: Bone pain has been shown to have a unique pathophysiology. Recent experimental (animal) models have revealed that, parallel to increased bone destruction, ipsilateral spinal cord segments that receive primary input from the cancerous femur exhibit several notable neurochemical changes. These mandate the use of opioid doses sufficient to inhibit the observed nociceptive behaviours; these doses are greater than those required to alleviate pain behaviours of com…
A new method for radiochemical separation of arsenic from irradiated germanium oxide.
2005
Abstract Radioarsenic labelled radiopharmaceuticals could be a valuable asset to Positron Emission Tomography (PET). In particular, the long half-lives of 72 As ( T 1/2 =26 h) and 74 As ( T 1/2 =17.8 d) allow to investigate slow physiological or metabolical processes, like the enrichment and distribution of antibodies in tumor tissue. This work describes the direct production of no-carrier-added (nca) arsenic isotopes *As, with *=71, 72, 73, 74 or 77, the reaction to [*As]AsI 3 and its radiochemical separation from the irradiated solid germanium oxide via polystyrene-based solid-phase extraction. The germanium oxide target, irradiated at a cyclotron or a nuclear reactor, is dissolved in con…
Post-elution processing of 44Ti/44Sc generator-derived 44Sc for clinical application
2009
The (44)Ti/(44)Sc (T(1/2)(44)Ti=60a) generator provides cyclotron-independent access to positron-emitting (44)Sc (T(1/2)=3.97d) for PET imaging. This work aims to post-elution processing of initial (44)Sc generator eluates in order to reduce its volume, HCl concentration and remove the oxalate anions. The on-line adsorption of (44)Sc on cationic resin AG 50W-X8 (200-400 mesh, H(+)-form) is achieved with >98% efficacy. Subsequently, the purified (44)Sc is desorbed by using 3ml of 0.25M ammonium acetate (pH=4.0). The post-processing takes 10min. The overall yield of the post-processing reached 90%, which is referred to the (44)Sc obtained from the (44)Ti/(44)Sc generator. In addition to the c…
Monte Carlo dosimetric study of the BEBIG Co-60 HDR source
2005
Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there are no dosimetric data available in the literature. The Monte Carlo code GEANT4 has been used to obtain the TG43 parameters and the 2D dose rate table in Cartesian coordinates of the BEBIG Co-60 HDR source. The dose rate constant, radial dose function and anisotropy function have been calculated and are presented in a tabular form as w…
End-to-end tests using alanine dosimetry in scanned proton beams
2018
This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…
Determination of CsI(Tl) scintillation time constants and intensities by direct fitting of digitized waveforms in the CHIMERA 4π multidetector
2012
The design of modern multi-detector arrays for Intermediate Energy Nuclear Physics experiments has to face the problem of the improvement of the Charge and Mass Identification of Heavy and Light Charged Products. Most of the detector arrays developed for the identification of mass and atomic number of the emitted fragments, use detection units composed by thin silicon detectors and by thick scintillator crystals read-out by photodiodes. The light output of the CsI(TI) crystal can be modeled - at least in a given energy range - with a combination of two exponential functions with different time constants. The possibility of storing the digitized waveforms allows performing further off-line a…
Inter/intramolecular Cherenkov radiation energy transfer (CRET) from a fluorophore with a built-in radionuclide.
2014
The Cherenkov radiation (CR) from [(18)F]-FDG, [(177)Lu]-LuCl3 and [(90)Y]-YCl3 was detected and CR energy transfer (CRET) to several fluorophores was examined. Subsequent fluorescence emission was found to be a function of the position of absorption bands with respect to the CR peak, energy of emitted particles, radionuclide/fluorophore loading, and fluorophore brightness. A variant of the best fluorophore with a built-in radionuclide was synthesized to achieve inter- and intra-molecular CRET.
Assessment of Gamma Dose Rate at Mine Waste Dump
2013
Abstract Exploitation of coal deposits in Upper Silesia is associated with production of large quantities of waste deposited at dumps. The tested samples from five dumps showed different radioactivity from each other. Radioactivity measurements made it possible to analyze the degree of risk with the factors specified by UNSCEAR such as radium equivalent activity Raeq, internal Ein and external Eex occupancy factor. There is a raised level of radiation in dumps as compared with outside dump areas. In the study area, however, there is no risk associated with elevated levels of radiation in relation to standards established by the Council of Ministers of the ionizing radiation dose limits.