Search results for "Radiometry"

showing 10 items of 170 documents

Power saturation of ESR signal in ammonium tartrate exposed to 60Co gamma-ray photons, electrons and protons.

2006

Abstract Marrale, M., Brai, M., Triolo, A., Bartolotta, A. and D'Oca, M. C. Power Saturation of ESR Signal in Ammonium Tartrate Exposed to 60Co γ-Ray Photons, Electrons and Protons. Radiat. Res. 166, 802–809 (2006). In this paper we present an investigation of the electron spin resonance (ESR) line shape of ammonium tartrate (AT) dosimeters exposed to radiation with different linear energy transfer (LET). We exposed our dosimeters to γ-ray photons (60Co), 7 MeV and 14 MeV initial energy electrons, and 19.3 MeV initial energy protons. The differences in the power saturation behavior of ESR spectra of AT irradiated with photons, electrons and protons could be correlated to the effective LET o…

PhotonBiophysicsLinear energy transferElectronsElectronRadiationRadiation DosageSensitivity and Specificitylaw.inventionlawRadiology Nuclear Medicine and imagingLinear Energy TransferIrradiationCobalt RadioisotopesElectron paramagnetic resonanceRadiometrySaturation (magnetic)TartratesPhotonsRadiationDosimeterChemistryElectron Spin Resonance SpectroscopyReproducibility of ResultsDose-Response Relationship RadiationAmmonium Tartrate 60Co -Ray Photons Electrons and Protons.Gamma RaysAtomic physicsProtonsAlgorithmsRadiation research
researchProduct

Sensitivity of alanine dosimeters with gadolinium exposed to 6 MV photons at clinical doses.

2011

In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on …

PhotonESR dosimetryGadoliniumMonte Carlo methodAccelerationBiophysicschemistry.chemical_elementGadoliniumLinear particle acceleratorRadiology Nuclear Medicine and imagingIrradiationRadiometryMonte Carlo simulationAlaninePhotonsRadiationDosimeterAlanineChemistryX-RaysRadiochemistryElectron Spin Resonance SpectroscopyDose-Response Relationship RadiationSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Alanine dosimeters gadoliniumLinear ModelsSensitivity (electronics)Monte Carlo MethodRadiation research
researchProduct

Characterization of PTW-31015 PinPoint ionization chambers in photon and proton beams

2018

The increased use of complex forms of radiotherapy using small-field photon and proton beams has invoked a growing interest in the use of micro-ionization chambers. In this study, 48 PTW-TM31015 PinPoint-type micro-ionization chambers that are used in the commissioning and patient specific QA of a proton pencil beam scanning (PBS) delivery system have been characterized in proton and high-energy photon beams. In both beam modalities, the entire set of PinPoint chambers was characterized by imaging them, by evaluating their stability using check source measurements, by experimentally determining the ion recombination, polarity effect and by cross calibrating them in terms of absorbed dose to…

PhotonProton030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticscross-calibrationIonizationProton TherapyCalibrationHumansDosimetryRadiology Nuclear Medicine and imagingCobalt RadioisotopesRadiometryPencil-beam scanningpolarity effectPinPoint ionization chamberPhysicsPhotonsion recombinationRadiological and Ultrasound Technologybusiness.industryphoton030220 oncology & carcinogenesisCalibrationPhysics::Accelerator PhysicsProtonLaser beam qualityProtonsbusinessRelative Biological EffectivenessBeam (structure)Physics in Medicine & Biology
researchProduct

The FiR 1 photon beam model adjustment according to in-air spectrum measurements with the Mg(Ar) ionization chamber.

2014

Abstract The mixed neutron–photon beam of FiR 1 reactor is used for boron–neutron capture therapy (BNCT) in Finland. A beam model has been defined for patient treatment planning and dosimetric calculations. The neutron beam model has been validated with an activation foil measurements. The photon beam model has not been thoroughly validated against measurements, due to the fact that the beam photon dose rate is low, at most only 2% of the total weighted patient dose at FiR 1. However, improvement of the photon dose detection accuracy is worthwhile, since the beam photon dose is of concern in the beam dosimetry. In this study, we have performed ionization chamber measurements with multiple b…

PhotonQuantitative Biology::Tissues and OrgansPhysics::Medical PhysicsMonte Carlo methodAnalytical chemistryBoron Neutron Capture TherapySensitivity and SpecificityOpticsNuclear ReactorsDosimetryPenelopeIonization ChamberDosimetryComputer SimulationPhoton beamRadiometryMonte CarloPhysicsPhotonsRadiationModels Statisticalbusiness.industryAirRadiotherapy Planning Computer-AssistedReproducibility of ResultsEquipment DesignNeutron radiationEquipment Failure AnalysisIonization chamberBNCTPhysics::Accelerator PhysicsComputer-Aided DesignDose ratebusinessMCNP5Beam (structure)Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Phantom size in brachytherapy source dosimetric studies

2004

An important point to consider in a brachytherapy dosimetry study is the phantom size involved in calculations or experimental measurements. As pointed out by Williamson [Med. Phys. 18, 776-786 (1991)] this topic has a relevant influence on final dosimetric results. Presently, one-dimensional (1-D) algorithms and newly-developed 3-D correction algorithms are based on physics data that are obtained under full scatter conditions, i.e., assumed infinite phantom size. One can then assume that reference dose distributions in source dosimetry for photon brachytherapy should use an unbounded phantom size rather than phantom-like dimensions. Our aim in this paper is to study the effect of phantom s…

Photonmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyModels BiologicalSensitivity and SpecificityImaging phantomRelative biological effectivenessmedicineHumansScattering RadiationDosimetryComputer SimulationPoint (geometry)RadiometryRadioisotopesPhysicsPhantoms Imagingbusiness.industryRadiotherapy Planning Computer-AssistedReproducibility of ResultsRadiotherapy DosageGeneral MedicineRadiusComputational physicsOrgan SpecificityBody BurdenRadiopharmaceuticalsNuclear medicinebusinessMonte Carlo MethodAlgorithmsRelative Biological EffectivenessMedical Physics
researchProduct

Collision-kerma conversion between dose-to-tissue and dose-to-water by photon energy-fluence corrections in low-energy brachytherapy

2016

The AAPM TG-43 brachytherapy dosimetry formalism, introduced in 1995, has become a standard for brachytherapy dosimetry worldwide; it implicitly assumes that charged-particle equilibrium (CPE) exists for the determination of absorbed dose to water at different locations, except in the vicinity of the source capsule. Subsequent dosimetry developments, based on Monte Carlo calculations or analytical solutions of transport equations, do not rely on the CPE assumption and determine directly the dose to different tissues. At the time of relating dose to tissue and dose to water, or vice versa, it is usually assumed that the photon fluence in water and in tissues are practically identical, so tha…

Photonmedicine.medical_treatmentBrachytherapyMonte Carlo methodBrachytherapyPhoton energyRadiation DosageFluence030218 nuclear medicine & medical imaging03 medical and health sciencesKerma0302 clinical medicinemedicineHumansDosimetryRadiology Nuclear Medicine and imagingRadiometryPhysicsPhotonsRadiological and Ultrasound Technologybusiness.industryWaterRadiotherapy DosageComputational physics030220 oncology & carcinogenesisAbsorbed doseNuclear medicinebusinessMonte Carlo MethodPhysics in Medicine and Biology
researchProduct

Determination of sea surface temperature at large observation angles using an angular and emissivity-dependent split-window equation

2007

Abstract This paper proposes an angular and emissivity-dependent split-window equation that permits the determination of the sea surface temperature (SST) to a reasonable level of accuracy for any observation angle, including large viewing angles at the image edges of satellite sensors with wide swaths. This is the case of the MODIS radiometer both on EOS Terra/Aqua platforms, with observation angles of up to 65° at the surface, for which the split-window equation has been developed in this study. The algorithm takes into account the angular dependence of both the atmospheric correction (due to the increase of the atmospheric optical path with angle) and the emissivity correction (since sea…

PhysicsBrightnessRadiometerAtmospheric correctionSoil ScienceGeologyPhysics::GeophysicsSea surface temperatureEmissivityRadiometrySatelliteBlack-body radiationComputers in Earth SciencesPhysics::Atmospheric and Oceanic PhysicsRemote sensingRemote Sensing of Environment
researchProduct

Monte Carlo calculation of beam quality correction factors for PTW cylindrical ionization chambers in photon beams.

2020

The beam quality correction factor k Q for megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in water and the absorbed dose to the active air volume of the chambers for photon beams in the range 4 to 24 MV. Of the nine ionization chambers analysed, only five are included in the current version of…

PhysicsPhotonsPhotonRadiological and Ultrasound TechnologyMonte Carlo methodUncertaintyWater030218 nuclear medicine & medical imagingNuclear physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisIonizationAbsorbed doseIonization chamberRelative biological effectivenessDosimetryRadiology Nuclear Medicine and imagingLaser beam qualityRadiometryMonte Carlo MethodRelative Biological EffectivenessPhysics in medicine and biology
researchProduct

Monte Carlo study of microdosimetric diamond detectors

2015

Ion-beam therapy provides a high dose conformity and increased radiobiological effectiveness with respect to conventional radiation-therapy. Strict constraints on the maximum uncertainty on the biological weighted dose and consequently on the biological weighting factor require the determination of the radiation quality, defined as the types and energy spectra of the radiation at a specific point. However the experimental determination of radiation quality, in particular for an internal target, is not simple and the features of ion interactions and treatment delivery require dedicated and optimized detectors. Recently chemical vapor deposition (CVD) diamond detectors have been suggested as …

PhysicsPhotonsWork (thermodynamics)PhotonRadiological and Ultrasound Technologybusiness.industryDetectorMonte Carlo methodUncertaintyDiamondRadiationengineering.materialIonOpticsengineeringRadiometryRadiology Nuclear Medicine and imagingDiamondProtonsRadiometrybusinessMonte Carlo MethodPhysics in Medicine and Biology
researchProduct

Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type137Cs sources

2001

Basic dosimetric data for the Walstam CDC.K-type low dose rate 137Cs sources in water have been calculated using Monte Carlo techniques. These sources, CDC.K1 -K3 and CDC.K4, are widely used in a range of applicators and moulds for the treatment of intracavitary and superficial cancers. Our purpose is to improve existing data about these sources using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water have been calculated around these sources and are presented as conventional 2D Cartesian look-up tables. Also the AAPM Task Group 43 formalism for dose calculation has been applied. The calculated dose rate constant for the CDC.K1-K3 source is A = 1.106 +/- 0.001…

PhysicsPolynomial regressionModels StatisticalRadiological and Ultrasound TechnologyRadiotherapy Planning Computer-AssistedMonte Carlo methodSievert integrallaw.inventionComputational physicsCesium RadioisotopeslawAnisotropyHumansDosimetryRadiology Nuclear Medicine and imagingCartesian coordinate systemStatistical physicsLow dose rateRadiometryDose rateAnisotropyMonte Carlo MethodAlgorithmsSoftwarePhysics in Medicine and Biology
researchProduct