Search results for "Reference Standards"
showing 10 items of 156 documents
Determination of microcystins in biological samples by matrix solid-phase dispersion and liquid chromatography–mass spectrometry
2005
A method for the detection and quantification of the microcystins (MCs)-MC-LR, MC-RR and MC-YR-in biological samples by matrix solid-phase dispersion (MSPD) has been developed. The optimum extraction conditions were 500 mg of liver or kidney, C18 bonded silica as dispersant, and a mixture methanol-water (70:30) as eluent. The MCs were determined by liquid chromatography electrospray mass spectrometry (LC/ES/MS). Recoveries of biological extracts at three different spiked levels (1-10 mg kg(-1)) ranged from 40.5 to 87.0% in liver, and from 52.5 to 74.5 in kidney. R.S.D.s were < 15.6% and < 10.6%, respectively. The detection and quantification limits were 0.05 and 0.5 mg kg(-1), for all MCs. …
Hepatocytes cultured in alginate microspheres: an optimized technique to study enzyme induction.
2004
An important application of hepatocyte cultures is identification of drugs acting as inducers of biotransformation enzymes that alter metabolic clearance of other therapeutic agents. In the present study we optimized an in vitro system with hepatocytes cultured in alginate microspheres that allow studies of enzyme induction with excellent sensitivity. Induction factors obtained with standard inducers, such as 3-methylcholanthrene or phenobarbital, were higher compared to those with conventional hepatocyte co-cultures on collagen coated dishes. This is illustrated by activities of 7-ethoxyresorufin-O-deethylase (EROD) after incubation with 5 microM 3-methylcholanthrene (3-MC), a standard ind…
Accuracy of CT and MRI to assess resection margins in primary malignant bone tumours having histology as the reference standard.
2018
AIM To evaluate the accuracy of magnetic resonance imaging (MRI) and computed tomography (CT) in assessing the resection margins of primary malignant bone tumours. MATERIALS AND METHODS Resected primary malignant bone tumour specimens removed from 46 patients (27 male; mean age: 48±22 years) were imaged using MRI (fat-saturated proton density-weighted and three-dimensional fat-suppressed T1-weighted gradient-recalled-echo) and CT immediately after surgery. A radiologist and an orthopaedist evaluated bone and soft-tissue margins of the specimens on both examinations. Histological evaluation was performed by a senior orthopaedic oncology pathologist. Margins were classified as R0 (safe margin…
Rapid mycotoxin analysis in human urine: A pilot study
2011
A simple and rapid method effective for quantitative determination of deoxynivalenol (DON), T-2 toxin (T-2), HT-2 toxin (HT-2), zearalenone (ZEN), ochratoxin A (OTA), aflatoxins (AFs) B(1), B(2), G(1) and G(2) and fumonisins FB(1) and FB(2) in urine was developed. The urine was diluted with phosphate buffer solution (PBS) and thoroughly mixed. For clean-up and extraction, the mixture was loaded on a MYCO 6in1 IAC. Hybrid triple quadrupole-linear ion trap mass spectrometer (QTrap) was used for the detection. Extra tools for confirmation of selected mycotoxins in positive samples, Information Dependent Acquisition (IDA) experiments, were also developed. The use of immunoaffinity columns follo…
Mid-sagittal plane detection for advanced physiological measurements in brain scans
2019
Objective The process of diagnosing many neurodegenerative diseases, such as Parkinson's and progressive supranuclear palsy, involves the study of brain magnetic resonance imaging (MRI) scans in order to identify and locate morphological markers that can highlight the health status of the subject. A fundamental step in the pre-processing and analysis of MRI scans is the identification of the mid-sagittal plane, which corresponds to the mid-brain and allows a coordinate reference system for the whole MRI scan set. Approach To improve the identification of the mid-sagittal plane we have developed an algorithm in Matlab® based on the k-means clustering function. The results have been compared …
Cell line DNA typing in forensic genetics—the necessity of reliable standards
2003
The incorporation of reference DNA is crucial to the validation of any DNA typing protocol. This paper aims to provide a panel of reference DNAs for actual forensic profiling strategies, i.e. autosomal and gonosomal STR typing as well as mtDNA sequencing. We have characterised three human lymphoid cell lines, GM9947, GM9948 and GM3657, and considered 58 autosomal and gonosomal microsatellites as well as the mitochondrial control region sequence. Well-established markers and STRs recently developed for forensic use were involved. K562 DNA samples which we purchased from two different suppliers were also analysed. They revealed conflicting results with regard to the ChrX STR marker genotype. …
Normal Reference Ranges for Echocardiography: Rationale, study design, and methodology (NORRE Study)
2013
International audience; BACKGROUND: Availability of normative reference values for cardiac chamber dimensions, volumes, mass, and function is a prerequisite for the accurate application of echocardiography for both clinical and research purposes. However, due to the lack of consistency in current echocardiographic 'reference values', their use for clinical decision-making remains questionable. AIMS: The aim of the 'Normal Reference Ranges for Echocardiography Study (NORRE Study)' is to obtain a set of 'normal values' for cardiac chamber geometry and function in a large cohort of healthy Caucasian individuals aged over a wide range of ages (25-75 years) using both conventional and advanced e…
Dabigatran after Short Heparin Anticoagulation for Acute Intermediate-Risk Pulmonary Embolism: Rationale and Design of the Single-Arm PEITHO-2 Study
2017
AbstractPatients with intermediate-risk pulmonary embolism (PE) may, depending on the method and cut-off values used for definition, account for up to 60% of all patients with PE and have an 8% or higher risk of short-term adverse outcome. Although four non-vitamin K-dependent direct oral anticoagulants (NOACs) have been approved for the treatment of venous thromboembolism, their safety and efficacy as well as the optimal anticoagulation regimen using these drugs have not been systematically investigated in intermediate-risk PE. Moreover, it remains unknown how many patients with intermediate-high-risk and intermediate-low-risk PE were included in most of the phase III NOAC trials. The ongo…
Evaluation of prostate segmentation algorithms for MRI: The PROMISE12 challenge
2014
Contains fulltext : 137969.pdf (Publisher’s version ) (Open Access) Prostate MRI image segmentation has been an area of intense research due to the increased use of MRI as a modality for the clinical workup of prostate cancer. Segmentation is useful for various tasks, e.g. to accurately localize prostate boundaries for radiotherapy or to initialize multi-modal registration algorithms. In the past, it has been difficult for research groups to evaluate prostate segmentation algorithms on multi-center, multi-vendor and multi-protocol data. Especially because we are dealing with MR images, image appearance, resolution and the presence of artifacts are affected by differences in scanners and/or …
Development and validation of a radioimmunoassay for serum melatonin.
1989
A radioimmunoassay using N-[3-(4-hydroxy-3-[4-hydroxy-3- [125I]iodophenylpropionyl)]-5-methoxytryptamine as tracer for determination of melatonin in the serum of different species is described. Melatonin antisera were raised in rabbits by immunization with a bovine serum albumin conjugate of N-[3-(2-aminoethyl)-5-methoxy indole] hemisuccinamide. A single high affinity, specific antiserum was obtained. In contrast to previous studies, the tracer was synthesised in one step in the absence of water, giving an excellent yield of highly pure product. No chromatographic purification step was needed. Polyethylene glycol in combination with goat antirabbit immunoglobulins was used to separate bound…