Search results for "Refractive"
showing 10 items of 559 documents
Influence of the drawing process on the defect generation in multistep-index germanium-doped optical fibers
2009
International audience; Variation of germanium lone pair center (GLPC) concentration in germanosilicate multistep-index optical fibers and preforms was studied using confocal microscopy luminescence technique. The experimental results provide evidence that in the central core region ([Ge] ~11 wt. % ) of our specific canonical samples the ratio [GLPC]/[Ge] is five times larger in fiber than in preforms. The relative influence of the glass composition and of the drawing process on the generation efficiency of the GLPC defects that drive the glass photosensitivity is discussed. The radial distribution of these defects suggests a possible enhancement of the defect creation related to the intern…
Changes in tear film metrics and ocular signs induced by different types of refractive correction in an aging population
2018
La integridad de la superficie ocular, en otras palabras, su capacidad para responder adecuadamente a los desafíos ambientales, depende de la integración adecuada de la información desde la superficie ocular, la transmisión de la señal creada hacia el cerebro y la generación de una respuesta, que modulará la función secretora así como la inmunidad local de la superficie ocular. Es fácilmente comprensible que cualquier alteración de uno de los tres pasos de este ciclo cerrado pueda desencadenar una respuesta inapropiada y desequilibrar aún más los mecanismos compensatorios que tienen lugar en la superficie ocular. La unidad funcional de la lágrima se puede definir como un conjunto de estruct…
Effects of rapid thermal annealing on the optical properties of low-loss 1.3μm GaInNAs∕GaAs saturable Bragg reflectors
2004
We report studies of the effect of rapid thermal annealing (RTA) on the optical properties of a low-loss 1.3 mum saturable Bragg reflector (SBR), consisting of a GaInNAs/GaAs single quantum well embedded in an AlAs/GaAs Bragg reflector grown monolithically on a GaAs substrate. RTA gives rise to a blueshift of the photoluminescence (PL) peak (and therefore of the excitonic absorption peak) and an enhancement of PL intensity, while the reflectivity properties including peak reflectivity and bandwidth are not degraded. Temperature dependent photoluminescence measurements show that the RTA-induced blueshift of photoluminescence consists of two components: one originating from the increase of op…
Synthesis and characterization of chalcogenide glasses from the system Ga-Ge-Sb-S and preparation of a single-mode fiber at 1.55 μm
2008
International audience; The aim of this work is to study different compositions in the Ga-Ge-Sb-S system for the definition of two compositions compatible with the elaboration of a single-mode fiber at the 1.55 μm telecom wavelength. The variations of the glass transition temperature (Tg), the dilatation coefficient (α) and the refractive index (n) have been studied for two glasses series: GaxGe25−xSb10S65 (series 1), Ga5Ge25−xSb10S60+x (series 2). This study has lead to the choice of the Ga4Ge21Sb10S65 composition as clad glass for the preparation of the single-mode fiber and Ga5Ge20Sb10S65 composition as the core. The discrepancies for the studied parameters between the core and clad comp…
Absolute measurement of quadratic nonlinearities from phase-matched second-harmonic generation in a single KTP crystal cut as a sphere
1997
We determine within an accuracy of ∼10% the absolute magnitude of the quadratic effective coefficients of types I and II phase-matched second-harmonic generation from conversion efficiency measurements in a single nonlinear crystal cut as a sphere. The agreement is good with measurements performed in thin parallelepipedal samples. The material studied is KTiOPO4, for which improved Sellmeier equations are given.
Light-induced transmission nonlinearities in gallium selenide
1999
The intensity of a He–Ne laser (633 nm, 5 mW) transmitted by different GaSe samples is observed to change in correlation with a Nd-yttrium–aluminum–garnet laser pulse (532 nm, 7.8 ns, 3 mJ) which excites them. Such time response has been attributed to a nonlinear optical effect, i.e., a decrease in the refractive index due to the exciton screening by the photogenerated carriers. A calculation of the absorption coefficient and refractive index at different carrier concentrations has led to a reconstruction of transmittance transients which fully agree with the experimental data at different incident intensities and temperatures. Chantal.Ferrer@uv.es ; Jaqueline.Bouvier@uv.es ; Miguel.Andres@…
Synthesis and characterization of bi-functional photorefractive polymers
2001
Abstract A novel bi-functional photorefractive acrylate polymer with pendant carbazolyl groups and azo derivatives as side chains was synthesized, in which azo derivatives as electro-optic chromophores and carbazolyl as photoconductive moiety were covalently linked on the acrylate backbone. Photorefractive experiments showed that a high two-beam coupling gain coefficient of 93 cm −1 , diffraction efficiency of 12% and electro-optic coefficient of 26 pm/V were obtained. With increasing writing beam's intensity, the two-beam coupling enhanced gradually, and then reached saturation. Using the method of four-wave mixing, the photoisomerization grating was observed.
Isobaric Vapor−Liquid Equilibria of the Water + 2-Propanol System at 30, 60, and 100 kPa
1996
Isobaric vapor−liquid equilibria were obtained for the water + 2-propanol system at 30, 60, and 100 kPa. The activity coefficients were found to be thermodynamically consistent by the methods of Van Ness−Byer−Gibbs, Kojima, and Wisniak. The data were correlated with five liquid phase activity coefficient models (Margules, Van Laar, Wilson, NRTL, and UNIQUAC).
Accuracy and accommodation capability of a handheld autorefractor
2000
Purpose: To determine the accuracy of measurement by the Nikon Retinomax handheld autorefractor and its ability to relax accommodation. Setting: Pediatric Section, Department of Ophthalmology, University of Mainz, Germany. Methods: To perform a series of comparative measurements, autorefractor readings were obtained on healthy young adults (students) and on children aged 2 to 12 years. The autorefractor readings were compared with subjective refractions of the young adults and with cycloplegic retinoscopy of the children. Results: In adults, the accuracy of the handheld autorefractor measurements was comparable to that of conventional tabletop autorefractors. In children, the autorefractor …
Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation
2011
PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…