Search results for "Relative"

showing 10 items of 1094 documents

The influence of calculation method and relative strength on the load-velocity relationship in bench press exercise

2021

Purpose The objective of this study was: (1) to compare the effect of the calculation method using average (Avalue), and best value (Bvalue) of Mean Propulsive Velocity (MPV) on the Load Velocity Profile (LVprofile) during the barbell bench press exercise in elite handball players. In addition, (2) to analyze the relationship between the individual coefficient of variation (CVind) of an incremental load protocol in the bench press exercise with relative strength (Frel) in professional handball players. Methods Nineteen elite international handball players (age 18 [±1] y; body mass 93 [±14] kg; height 191 [±6] cm) performed an incremental test during the barbell bench press exercise. General…

business.industryResistance trainingStructural engineeringRelative strengthbusinessBench pressSocial Sciences (miscellaneous)MathematicsInternational Journal of Sports Science & Coaching
researchProduct

Heparin versus 0.9% sodium chloride intermittent flushing for prevention of occlusion in central venous catheters in adults

2014

Background Heparin intermittent flushing is a standard practice in the maintenance of patency in central venous catheters. However, we could find no systematic review examining its effectiveness and safety. Objectives To assess the effectiveness of intermittent flushing with heparin versus 0.9% sodium chloride (normal saline) solution in adults with central venous catheters in terms of prevention of occlusion and overall benefits versus harms. Search methods The Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched December 2013) and the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 11). Searches were …

business.industrymedicine.medical_treatmentContext (language use)Confidence intervalClinical trialCatheterRelative riskAnesthesiaMeta-analysisMedicinePharmacology (medical)businessSalineCentral venous catheterRC
researchProduct

Novel nanocrystalline cores for EMI suppression in cables: characterization methodology and performance study

2021

El control de las interferencias electromagnéticas (EMI) en dispositivos electrónicos es un problema cada vez mayor al que se enfrentan los diseñadores para garantizar que los dispositivos cumplan con los requisitos de compatibilidad electromagnética (EMC) para operar simultáneamente sin inferir entre sí. Este hecho se debe a la tendencia hacia una mayor integración de componentes, la reducción del tamaño y grosor de las placas de circuito impreso (PCB) y la miniaturización de las carcasas de los dispositivos. Además, otros factores como el empleo de frecuencias de conmutación más altas en los convertidores de potencia y las velocidades de datos de comunicación en los circuitos digitales. C…

cable filtering:CIENCIAS TECNOLÓGICAS [UNESCO]ceramic materialsinsertion lossimpedancerelative permeabilitynanocrystallinefinite element method simulationUNESCO::CIENCIAS TECNOLÓGICASelectromagnetic compatibilityelectromagnetic interference suppressors
researchProduct

PAMPA—a drug absorption in vitro model

2004

Parallel artificial membrane permeability assay (PAMPA) was used to measure the effective permeability, P(e), as a function of pH from 4 to 10, of 17 fluoroquinolones, including three congeneric series with systematically varied alkyl chain length at the 4'N-position of the piperazine residue. The permeability values spanned over three orders of magnitude. The intrinsic permeability, P(o), and the membrane permeability, P(m), were determined from the pH dependence of the effective permeability. The pK(a) values were determined potentiometrically. The PAMPA method employed stirring, adjusted such that the unstirred water layer (UWL) thickness matched the 30-100 microm range estimated to be i…

chemistry.chemical_classificationAbsorption (pharmacology)ChromatographyMembrane permeabilityAnalytical chemistrySynthetic membranePharmaceutical ScienceIntestinal absorptionPermeability (earth sciences)Piperazinechemistry.chemical_compoundchemistryRelative permeabilityAlkylEuropean Journal of Pharmaceutical Sciences
researchProduct

Viscometric study of mixtures of neutral and charged polymers in aqueous solution

1997

The viscosity behaviour of aqueous mixtures formed by a polyelectrolyte (A) and a neutral polymer (B) such as polystyrene sulfonate (PSS)-polyvinylpyrrolidone (PVP) and polylysine (PLL)-PVP has been studied at 25°C. The intrinsic viscosity and viscosity interaction parameter of each polymer in water have been determined and have served us to estimate the compatibility of the different mixtures according to two different methodologies: (i) mixtures of two polymers in water as solvent and (ii) mixtures of either polymer A OFB in a solvent formed by either polymer B or A in water ("polymer solvent method"). By comparing the experimental and theoretical viscosity data it is clearly seen that: m…

chemistry.chemical_classificationAqueous solutionPolymers and PlasticsChemistryRelative viscosityIntrinsic viscosityOrganic ChemistryGeneral Physics and AstronomyPolymer architecturePolymerFlory–Huggins solution theoryPolyelectrolyteViscosityChemical engineeringPolymer chemistryMaterials Chemistry
researchProduct

The Swelling Behavior of Polyelectrolyte Multilayers in Air of Different Relative Humidity and in Water

2002

The swelling properties of physisorbed polyelectrolyte multilayer self-assemblies with alternating polyion charge in humid air and in aqueous environment were investigated via X-ray and neutron reflectometry as well as optically, using surface plasmon spectroscopy. The sorption behavior was similar to that found for neutral polymers and was related to an internal screening of the charges of the adjacent layers owing to the high entanglement of the polyelectrolyte chains and the resulting low mobility of the polymer segments. The screening was found to be incomplete only in the top layer, resulting in a net charged surface.

chemistry.chemical_classificationAqueous solutionPolymers and PlasticsOrganic ChemistrySurface plasmonSorptionPolymerCondensed Matter PhysicsPolyelectrolytechemistryPolymer chemistryMaterials ChemistrymedicineRelative humidityNeutron reflectometryPhysical and Theoretical ChemistrySwellingmedicine.symptomMacromolecular Chemistry and Physics
researchProduct

Viscosity of Polymer Solutions over the Full Range of Composition: A Thermodynamically Inspired Two-Parameter Approach

2015

The approach yields the following relation for the relative viscosity η rel as a function of polymer concentration c (mass/volume): ln ηrel = c/(1 + pc + qc2). Reduced concentrations c (defined as c = c[η], where [η] is the intrinsic viscosity) are used instead of c to incorporate thermodynamic information. The parameters p and q account for changes in the free volume of the solvent caused by the polymer. The analysis of literature data for seven very dissimilar systems discloses the following common feature: p > 0 and q < 0. This means that the curves in the plots of ln ηrel as a function of c are normally located below the tangent at low c and above it at high c. The values of p and q cor…

chemistry.chemical_classificationChemistryGeneral Chemical EngineeringIntrinsic viscosityRelative viscosityThermodynamicsTangentGeneral ChemistryFunction (mathematics)PolymerIndustrial and Manufacturing EngineeringSolventViscosityVolume (thermodynamics)Industrial &amp; Engineering Chemistry Research
researchProduct

Isobaric Vapor−Liquid Equilibria for Water + Acetic Acid + Sodium Acetate

2003

Isobaric vapor−liquid equilibria for the binary water + sodium acetate and acetic acid + sodium acetate systems and ternary mixtures of water, acetic acid, and sodium acetate have been measured at 100 kPa with a recirculating still. The addition of sodium acetate to water + acetic acid mixtures produced an appreciable rise in equilibrium temperature but a small effect on the relative volatility of water, which was augmented at higher water solvent concentrations and decreased at lower concentrations. These effects increased with higher salt concentrations. The experimental binary data sets have been correlated using a modified Mock's electrolyte NRTL model, which takes into account the asso…

chemistry.chemical_classificationChromatographyRelative volatilityGeneral Chemical EngineeringInorganic chemistrySalt (chemistry)General ChemistryElectrolyteSolventAcetic acidchemistry.chemical_compoundchemistryNon-random two-liquid modelIsobaric processSodium acetateJournal of Chemical &amp; Engineering Data
researchProduct

t-Curves for n-Hexane

1992

The adsorption and desorption isotherms of n-hexane on powdered alumina and silica have been studied at 25°C over a wide range of relative pressures. Two t-curves for pore structure analysis are proposed, one for alumina (C = 12) and the second for silica (3 ≤ C ≤ 9). The statistical thickness t of the adsorbed n-hexane layer has been drawn as a function of the relative pressure assuming a maximal thickness of 0.55 nm and a mean thickness of 0.42 nm for the monolayer. The results are discussed in relation to previous published data.

chemistry.chemical_classificationChromatographyStructure analysisGeneral Chemical Engineeringlcsh:QD450-801Analytical chemistrylcsh:Physical and theoretical chemistry02 engineering and technologySurfaces and InterfacesGeneral Chemistry010501 environmental sciences01 natural sciencesHexanechemistry.chemical_compoundAdsorptionHydrocarbon020401 chemical engineeringchemistryDesorptionMonolayerRelative pressure0204 chemical engineeringLayer (electronics)0105 earth and related environmental sciencesAdsorption Science &amp; Technology
researchProduct

Influence of the physical state of water on the barrier properties of hydrophilic and hydrophobic films.

2000

Water transfer through different films, as a function of the physical state of water in contact with the film, the relative humidity difference, and the water vapor pressure difference, was investigated. The films were two synthetic packagings (hydrophobic polyethylene and hydrophilic cellophane) and an edible film. The physical state of water affects water sensitive films, such as cellophane, inducing a higher liquid water transfer due to interactions with the polymer. For hydrophobic polymers, such as polyethylene, neither the physical state of water nor the relative humidity has an influence on the water permeability. In complex system, such as an edible film composed of hydrophilic part…

chemistry.chemical_classificationChromatographyWater activityChemistryCellophaneSurface PropertiesVapour pressure of waterFood PackagingTemperatureCellophaneWaterGeneral ChemistryPolymerPolyethylenePermeabilitylaw.inventionchemistry.chemical_compoundChemical engineeringlawPolyethylenePhase (matter)Relative humidityVolatilizationGeneral Agricultural and Biological SciencesWater vaporJournal of agricultural and food chemistry
researchProduct